INSTALLATION, OPERATION & MAINTENANCE MANUAL
ENERGY RECOVERY VENTILATOR
EV130EV200EV300
RENEWAIRE.COM
MODEL: EV130
MODEL: EV200
MODEL: EV300
Page 1: ...INSTALLATION OPERATION MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR EV130 EV200 EV300 RENEWAIRE COM MODEL EV130 MODEL EV200 MODEL EV300...
Page 2: ...r you have a problem with excess humidity during cold weather ABOUT RENEWAIRE For over 30 years RenewAire has been a pioneer in enhancing indoor air quality IAQ in commercial and residential buildings...
Page 3: ...w Gross Airflow Supply Exhaust Pa in wg L S CFM L S CFM L S CFM 25 0 1 53 113 54 115 52 109 50 0 2 46 98 47 100 46 97 75 0 3 40 85 41 87 40 85 100 0 4 34 73 35 74 34 72 125 0 5 27 58 28 59 28 60 150 0...
Page 4: ...Summer 79 0 60 78 73 60 104 0 50 75 69 55 126 0 40 72 66 50 137 0 30 71 64 48 153 0 20 68 61 45 165 0 10 67 59 43 6 Typ 8 1 8 5 1 2 Typ 9 OA EA RA FA 34 Line Cord 28 3 4 Case 33 1 4 Overall 2 1 4 Typ...
Page 5: ...IT PERFORMANCE CORE PERFORMANCE Airflow CFM ESP in H2 0 Temp EFF Total EFF Winter Summer 122 0 70 81 77 64 149 0 60 79 75 61 168 0 50 78 73 59 176 0 40 78 72 59 186 0 30 77 72 58 192 0 20 77 71 57 207...
Page 6: ...ut Watts FLA 0 2 120 60 Single 315 297 CFM 3 3 UNIT PERFORMANCE CORE PERFORMANCE Airflow CFM ESP in H2 0 Temp EFF Total EFF Winter Summer 170 1 0 78 73 59 191 0 9 77 71 57 215 0 8 75 69 55 256 0 7 73...
Page 7: ...ed space or into any other structure Do not install the exhaust outlet and fresh air inlet through the roof The preferred mounting location for the unit is on a concrete foundation wall because the fo...
Page 8: ...not in use A central location such as a hallway is also acceptable but won t clear humidity and odors from baths and kitchens as rapidly Locate stale air return grilles RA near the ceiling on inside w...
Page 9: ...ick up Fresh Air to Furnace Return Air Trunkline Furnace Return Air Back into Return Air Separate Air and Fresh Air Supply Furnace Return Air Back into Supply Air Note ERV blower may be operated separ...
Page 10: ...amp circuit breaker Do not remove the unit s line cord 6 Do not install unit or controls where they can be reached from a tub or shower 7 This unit must be properly ducted to the outdoors 8 Outside a...
Page 11: ...lange opposite hanging bracket to structure Safety screws should similarly be installed passing through the hanging bracket and flange Make sure the screws which you must supply are properly selected...
Page 12: ...urnace and water heater exhausts or other sources of contamination or carbon monoxide Install 12 above ground level Never locate the fresh air inlet inside a structure INSTALLING OUTSIDE AIR AND EXHAU...
Page 13: ...tton controls F7 Typical Control Schematic DANGER OF ELECTRICAL SHOCK WHEN SERVICING AN INSTALLED UNIT ALWAYS UNPLUG UNIT BEFORE CONNECTING OR SERVICING CONTROLS WARNING Up to 6 PBL Controls wired in...
Page 14: ...V EV130 EV200 AND EV300 RENEWAIRE COM INSTALLATION OPERATION AND MAINTENANCE MANUAL 1 800 627 4499 14 MAINTENANCE SERVICE PARTS EV130 EV200 AND EV300 www renewaire com 800 627 4499 support renewaire c...
Page 15: ...e unit is the installing contractor As an alternative you may wish to produce your own filters Please follow these instructions Filters may be cut from a sheet or roll of 1 firm spun polyester filter...
Page 16: ...ire unlike other ventilation suppliers advanced ventilation solutions are all we do Our sole passion Which is why for all commercial projects we are the V in HVAC and the only name you need to know US...