UM-B-041
SmartBond Production Line Tool
User Manual
Revision 4.8
02-Nov-2022
CFR0012
80 of 170
© 2022 Renesas Electronics
Table 53: Flash Image Write
Option
Description
Write enable
This will enable the specific QSPI or OQSPI flash image programming test.
QSPI/OQSPI
QSPI refers to the QSPI interface using a QSPI compatible flash
OQSPI refers to the OSPI interface using a QSPI or OQSPI compatible flash
Verify image
By selecting this option, the PLT software will read back the contents of the flash
memory and compare them to the original image file. If these do not match, the
memory programming will fail.
Start address
The user can configure the flash start address where the image will be written.
Image path
Via this field, the user specifies the image file to be burned into the flash memory. A
.bin
binary file of any name can be selected.
7.2.7.3
Memory Read
Figure 67: Memory Read Test
Memory Read Tests
can have multiple instances with different settings. Tests can be added or
removed using the two buttons (e.g.,
and
in
) at the bottom right side of each panel.
Note:
When adding or removing a test, all settings are refreshed with the values written to the XML
file, meaning that any unsaved settings will be lost.
describes the memory read test options. With this test, the user can read up to 64MBytes of
data from any address from any available memory for the devices, such as OTP and QSPI. An
example of how the data appears on the log file is shown in
Figure 68: Memory Read Test Example Log File
Table 54: Memory Read Test
Option
Description
Read enable
This will enable the specific memory reading test.
Test name
The name assigned to each test. The assigned name will be shown on the tab and next to it
an indication showing whether the specific test is enabled or not.
Start address
Configures the start address. Valid addresses for OTP are 0x0000
– 0x0FFC.
Size
Number of bytes to read, up to 64MBytes. If data to be read are greater than 256 bytes, then
a file will be created to store the data under folder
mem_read_test
in the PLT execution path.
Memory type
The type of memory to read the data from. Available options are OTP, QSPI FLASH and
OQSPI FLASH.