Renesas Starter Kit+ for RZ/T2M
6. Configuration
R20UT4939EG0100 Rev. 1.00
Page 50 of 87
Apr 20, 2022
Table 6-33: Ethernet Configuration Option Links (3)
Signal name
MPU
MPU Peripheral Selection
Destination Selection
Pi
n
Por
t
Signal
Fit
DNF
Interface
/Function
Fit
DNF
ETH2_TXCLK
D3 P00_6
ETH2_TXCLK
R85,
CN23
(1-2 pin short)
-
IC16.37
-
-
CS5#
R85,
CN23
(2-3 pin short)
-
JA3-A.27
-
R296
ETH2_TXEN
B1 P00_2
ETH2_TXEN
R83
-
IC16.33
-
-
ETH2_TXD0
F3 P01_5
ETH2_TXD0
R89
-
IC16.38
-
-
ETH2_TXD1
H5 P01_4
ETH2_TXD1
R88
-
IC16.40
-
-
ETH2_TXD2
D1 P01_3
ETH2_TXD2
R87
-
IC16.41
-
-
ETH2_TXD3
D2 P01_2
ETH2_TXD3
R86
-
IC16.42
-
-
ETH2_RXCLK
C3 P24_1
ETH2_RXCLK
-
-
IC16.32
R105
-
ETH2_RXDV
F5 P00_1
ETH2_RXDV
-
-
IC16.30
R106
-
ETH2_RXD0
B3 P23_7
ETH2_RXD0
-
-
IC16.29
R107
-
ETH2_RXD1
C4 P24_0
ETH2_RXD1
-
-
IC16.27
R108
-
ETH2_RXD2
E5 P24_2
ETH2_RXD2
-
-
IC16.26
R109
-
ETH2_RXD3
B2 P00_0
ETH2_RXD3
-
-
IC16.25
R110
-
ETH2_REFCLK
C2 P00_3
ETH2_REFCLK
R84
-
IC11.2
R114
-
ETH2_REFCLK_25
-
-
ETH2_REFCLK
R114
R113
IC16.63
R265
-
ETH2_REFCLK_G*
1
R113, R163
R114
*
1
: In the default RSK+ configuration, ETH2_REFCLK_G signal is not connected to the XTAL1 pin of the
Ethernet controller IC (IC16). If you want to connect the external clock (X1) on the RSK+ to the Ethernet
controller IC, configure as shown in
below details the function of the switches associated with the Ethernet.
Table 6-34: Ethernet Configuration Switch Settings
SW6-1
Explanation
ON
Enable the external bus signal and Ethernet. *
1
OFF
Enables signals other than the external bus. (CAN, Emulator, I
2
C, etc.)
*
1
: BUS (SDRAM) and Ethernet port 2 cannot be used at the same time.
and
below details the function of the jumpers associated with the Ethernet.
Table 6-35: Ethernet Configuration Jumper Settings (1)
Reference Jumper Position
Explanation
CN17
Shorted Pin 1-2
Connect 3.3V Power rail to VCC1833_2. (When using SDRAM)
Shorted Pin 2-3
Connect 1.8V Power rail to VCC1833_2. (When using Ethernet port 2)
Table 6-36: Ethernet Configuration Jumper Settings (2)
Reference Jumper Position
Explanation
CN18, CN19,
CN20
Shorted Pin 1-2
When using 3 ports in the same PHY mode
Shorted Pin 2-3
When ports 0 and 1 use the same PHY mode and port 2 uses different PHY modes
*
: When using VCC1833_2 at 3.3 V, use a jumper setting of 2-3.
Summary of Contents for RZ/T2M