Renesas Solution Starter Kit for RX23W
5. User Circuitry
R20UT4446EG0102 Rev. 1.02
Page 21 of 41
Jun 22, 20
5.10 I
2
C Bus (Inter-IC Bus)
The RX23W features two I
2
C (Inter-IC Bus) interface modules. RIIC0 is connected to a 2Kbit EEPROM.
below details the connected device, and their connection to the MCU.
Table 5-10: I
2
C Bus Connections
I
2
C Bus signal
Function
MCU
Port
Pin
E2P-SDA
Data
P17
B1
E2P-SCL
Clock
P16
C3
5.11 Serial Sound Interface (SSI)
The RX23W microcontroller has one channel of serial digital sound interface (SSI), connected to the MCU
shows the connection relationship.
Table 5-11: SSI Connections
SSI Signal
*1
Function
MCU
Port
Pin
SSITXD0
Serial data output
P17
B1
SSIRXD0
Serial data input
P26
B2
SSIWS0
Word select
P27
B3
AUDIO_MCLK
Audio master clock
P30
A2
SSISCK0
Serial bit clock
P31
B4
*1
: This connection is a not available in the default RSSK configuration - refer to §6 for the required
modifications.
5.12 Touch Interface
The RX23W microcontroller is fitted with a four Touch Interface (slider) and one Touch Interfaces (key).
below details the connected devices, and their connections to the MCU.
Table 5-12: Touch Interface Connections
Touch Signal
Function
MCU
Port
Pin
TS4
Capacitance measurement terminal (Touch key)
P25
A1
TS23
Capacitance measurement terminal (Upper of touch slider)
PC5
G2
TS27
Capacitance measurement terminal (Middle upper of touch slider)
PC3
H1
TS30
Capacitance measurement terminal (Middle lower of touch slider)
PC2
H2
TS35
Capacitance measurement terminal (Lower of touch slider)
PC0
J1
TSCAP
LPF (Low-pass filter) connection terminal
PC4
G1