R01UH0822EJ0100 Rev.1.00
Page 447 of 1041
Jul 31, 2019
RX13T Group
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
(o) Counter Clearing by MTU3.TGRA Compare Match
In complementary PWM mode, MTU3.TCNT, MTU4.TCNT, and TCNTSA can be cleared by MTU3.TGRA compare
match when the TWCRA.CCE bit.
illustrates an operation example.
Note 1. Use this function only in complementary PWM mode 1 (transfer at crest).
Note 2. Do not specify synchronous clearing by another channel (do not set 1 in the SYNC0 to SYNC4 bits in the timer
synchronous register (TSYRA)).
Note 3. Do not set the PWM duty value to 0000h.
Note 4. Do not set the PSYE bit in timer output control register 1 (TOCR1A) to 1.
Figure 19.69
Example of Counter Clearing Operation by MTU3.TGRA Compare Match
(Output waveform is active-high)
Counter cleared by MTU3.TGRA
compare match
MTU3.TGRA
MTU3.TGRB
TCDRA
TDDRA
0000h
Output waveform
Output waveform#