Table 5-11 ELCL register settings (Outputs)
Register
Symbol
Register Name
Setting Description
ELOSEL0
Output signal select register
0
06H
Select the output signal [0] from logic cell block
L2.
ELOSEL3
Output signal select register
3
09H
Select the output signal [3] from logic cell block
L2.
ELOSEL4
Output signal select register
4
0EH
Select the output signal [3] from logic cell block
L3.
ELOSEL5
Output signal select register
5
0AH
Select the output signal [4] from logic cell block
L2.
ELOSEL6
Output signal select register
6
0FH
Select the output signal [4] from logic cell block
L3.
Figure 5-9 Settings of ELCL output
L2L0 Output Signal
L2F0 Output Signal
L3F0 Output Signal
L2F1 Output Signal
L3F1 Output Signal
ELOMONI7
ELOMONI6
ELOMONI5
ELOMONI4
ELOMONI3
ELOMONI2
ELOMONI1
ELOMONI0
ELOSEL0
ELOSEL3
:
ELOSEL4
ELOSEL5
ELOSEL6
ELOMONI
ELOSELn