background image

 User’s 

Manual 

REJ10J1817-0200

R0E001000EXT00 

Rev.2.00

Apr 16, 2010

External Trigger Cable for the E100 Emulator

 

 

1. Outline 

REJ10J1817-0200  Rev.2.00 

 

Page 1 of 4 

Apr 16 2010 

 

 

The external trigger cable R0E001000EXT00 allows tracing of 
external signals and output of events through the external trigger 
connector of the E100 emulator (R0E001000EMU00)

 

2. Package Components 

(See Figure 1)

 

 

Check to see if the R0E001000EXT00 package has all the 
following contents before using this product.

 

 

(1) R0E001000EXTE0 board............................................ 1 pc. 

(2) R0E001000EXTT0 board (with a cable)..................... 1 pc. 

(3) R0E001000FLX10 flexible cable................................ 1 pc. 

(4)  R0E001000EXT00 User's Manual (this document) 

 
 

3. Usage 

(See Figure 2)

 

 
The usage of the external trigger cable R0E001000EXT00 is 
shown in Figure 2. 

 

 

R0E001000EXTE0 board

(E100 emulator side)

R0E001000EXTT0 board with a cable 

(user system side)

R0E001000FLX10

flexible cable

 

 

Figure 1 Package Components of the R0E001000EXT 

 

After checking that the power supplies for the E100 emulator and the user system are turned off, connect the external trigger cable 
R0E001000EXT00 according to the following procedure. 
 
(1)

 

Connect R0E001000FLX10 to the R0E001000EXTE0 board. 

(2)

 

Open the lid (EXT) of the E100 emulator and connect the R0E001000EXTE0 board to the external trigger connector. 

(3)

 

Connect signals to the user-system connection sockets of R0E001000EXTT0. 

(4)

 

Connect R0E001000FLX10 to R0E001000EXTT0. 

 

Reviews: