2.3.6  Precautions for handling NQ, YQ, SA, and CA (using 30pin) 

 

(1) When taking the NQ from the box, press down on the body and take out the sponge first. 

(2) Since the pins of the YQ are thin and easily bent, be careful. When inserting it in the NQ, confirm that there are 

no bent pins. 

(3) When screwing a YQ soldered to a board to the NQ, fasten the screws in four places in turn using a #0 or #1 

Phillips precision screwdriver or torque driver after tentatively tightening them.  Fix the torque at 0.054 Nm 

(MAX.). 

If just one place is over tightened, it may cause poor contact.    Moreover, a board being connected to the YQ 

must have accessory holes in prescribed positions (four places: 

2.3 mm or 

3.3 mm).  The 

3.8 mm or 

4.3 

mm that is the screw head size is an area where wiring is prohibited. 

(4) In YQ and SA removal, since there is a danger of YQ pins being bent or broken when prying and wiggling, 

remove them gradually using a flat bladed screwdriver from four directions.    Moreover, to connect and use the 

YQ and SA, screw the YQ to the NQ according to the YQGUIDE (included with the YQ) using a 2.3 mm flat 

bladed screwdriver and then connect it to the SA.    Fix the torque at 0.054 Nm (MAX.).    If even one place is 

over tightened, it may cause poor contact. 

(5) For the NQ, YQ, and SA, since there is a danger that washing fluid on the structure will remain in the connector, 

do not perform washing. 

(6) NQ, IC, and YQ cannot be used in combination. 

(7) A NQ/YQ system cannot be used in an environment of vibrations or shocks. 

(8) It is assumed that this product will be used in system development and evaluation.    Moreover, when used in 

Japan, Electrical Appliance and Material Control Law and electromagnetic disturbance countermeasures have 

not been applied. 

(9) Since there are rare cases of shape change if the box is left for a long time in a place where it is 50°C or higher, 

for safekeeping, store it in a place where it is no higher than 40°C and direct sunlight does not hit it. 

(10) For details about handling the NQ, YQ, and SA, see the NQPACK series technical materials at the website of 

Tokyo Eletech Corporation. 

URL: http://www.tetc.co.jp/ 

(11) CA 

The CA is an optional product for IECUBE, and can be used to measure the waveform between IECUBE and 

the target system. 

Since the pins on the CA do not correspond to the pin layout in each device, the pin header cover must be 

mounted according to the device to be used.    For mounting methods of the pin header cover, refer to URL. 

 

2.3.7  Precautions for handling NQ (using 16pin or 20pin) 

 

(1) Do not perform cleaning by flux immersion or vapor. 

(2) Prying at insertion/removal might break the connector, therefore be sure to insert/remove vertically. 

(3) This system cannot be used in an environment of vibrations or shocks. 

(4) It is assumed that this product will be used in system development and evaluation. Moreover, when used in 

Japan, Electrical Appliance and Material Control Law and electromagnetic disturbance countermeasures 

have not been applied. 

(5) Since there are cases of shape change if the packing case is left for a long time in a place where it is 50°C 

or higher, for safekeeping, store it in a place where it is no higher than 40°C and direct sunlight does not hit it. 

 

Summary of Contents for QB-78K0FX2L

Page 1: ...User s Manual QB 78K0FX2L In Circuit Emulator User s Manual Rev 1 00 2012 5 Target Devices 78K0 FY2 L 78K0 FA2 L 78K0 FB2 L...

Page 2: ......

Page 3: ...et system when there is a potential difference between the GND of this product and GND of the target system If the connectors or cables are plugged unplugged while this product is in the power on stat...

Page 4: ...icrocontrollers This manual describes the basic setup procedures and how to set switches To understand the overall functions and usages of the QB 78K0FX2L Read this manual in the order of the CONTENTS...

Page 5: ...ch Documents Related to Development Tools User s Manuals Document Name Document Number QB 78K0FX2L In Circuit Emulator This manual Start R20UT0727E 78K0 Design R20UT0546E 78K0 Cording R20UT0782E 78K0...

Page 6: ...or 20pin 24 2 3 3 Mounting YQ to NQ using 30pin 25 2 3 4 Plugging EA into YQ using 30pin 25 2 3 5 Plugging EA into NQ using 16pin or 20pin 25 2 3 6 Precautions for handling NQ YQ SA and CA using 30pi...

Page 7: ...1 GENERAL The QB 78K0FX2L is an in circuit emulator for emulating the 78K0 Fx2 L Hardware and software can be debugged efficiently in the development of systems in which the 78K0 Fx2 L is used This ma...

Page 8: ...frequency Internal low speed oscillation clock 1 8 V VDD 5 5V 31 25kHz Note3 Operating temperature range 0 to 40 C No condensation Storage temperature range 15 to 60 C No condensation External dimens...

Page 9: ...rojection of power switch 2 Includes projection of screw that fixes rear space adapter 3 Rear space adapter can adjust the height from 30 mm longest to 0 mm shortest 4 Front space adapter can adjust t...

Page 10: ...057EJ0100 Rev 1 00 Page 10 of 37 2012 05 18 1 2 Names and Functions of Hardware Figure 1 1 Names of Parts of QB 78K0FX2L Top View Bottom View Power switch POWER Red LED USB connector Power supply conn...

Page 11: ...78K0FX2L is switched on Table 1 2 POWER Red LED LED LED State QB 78K0FX2L State Lit Power switch ON Not lit Power switch OFF or AC adapter not connected to QB 78K0FX2L Blinking Internal error occurre...

Page 12: ...protect SFR illegal access stack overflow or else Break functions Other Forcible break trace full break trace delay break timeout break timer overflow break Trace data types Program address program da...

Page 13: ...ine 4 AC adapter AC adapters classified by region 5 QB 78K0FX2L This product 6 Check pin adapter optional Adapter used for monitoring waveforms with oscilloscope 7 Emulation probe High characteristic...

Page 14: ...ors 3 The part number of 4 differs depending on the region of use See Table 1 7 Part Numbers of AC Adapter for IECUBE Classified by Region for the part numbers The IECUBE requires an AC adapter that m...

Page 15: ...1 6 Package Contents Remark For the package drawings of the connector adapter and probe refer to the following URL http www renesas com iecube 78k0 Table 1 5 Adapters and Connectors for Each Target D...

Page 16: ...ty card and software contract in one 5 Packing list Products supplied with QB 78K0FX2L T16GR 1 to 5 6 Emulation probe QB 80 EP 01T 7 Exchange adapter QB 16GR EA 02T 8 Target connector QB 16GR NQ 01T P...

Page 17: ...r IECUBE Classified by Region Product Destination Region Notes 1 2 Part NumberNote 3 Japan QB COMMON PW JP USA QB COMMON PW EA China QB COMMON PW CN Hong Kong QB COMMON PW HK South Korea QB COMMON PW...

Page 18: ...long the lines of the following procedure See 1 2 Names and Functions of Hardware for clock positions Clock settings 2 2 See Clock Settings 2 1 Software Settings Mounting and connecting connectors 2 3...

Page 19: ...lation with the resonator on the target system is not supported Therefore the in circuit emulator cannot emulate the oscillation operation of the clock on the target system Table 2 1 List of clock set...

Page 20: ...s manual for the debugger that will be used b When the clock a square wave is supplied from the target system The clock input from the target system is then used To input a clock from the target syst...

Page 21: ...5 18 Figure 2 1 Acrylic Board Removal Method As an oscillator Note to be mounted in the OSC1 socket in the emulator use the one that satisfies the following specifications Supply voltage 5 0V Output l...

Page 22: ...into the socket take care for the pin 1 position 2 Internal high speed oscillation clock This method uses the clock inside the emulator by configuring the use of the high speed oscillation clock in t...

Page 23: ...of the four projections on the base of the NQ and adhere the NQ to the user board clean the surface of the target system board using alcohol or the like If alignment of target system pads to NQ leads...

Page 24: ...lean the back of the NQ as well as the surface of the target system using alcohol or the like Align the NQ leads along the target system pads 2 Preserve the soldering conditions use Sn 3 5Ag 0 5Cu and...

Page 25: ...eat tightening causes bad connections However four screws for fitting to the NQ M2 x 10 mm 4 units are included with the YQ Figure 2 4 Mounting of EA YQ and NQ EA YQGUIDE supplied with YQ YQ TC Target...

Page 26: ...environment of vibrations or shocks 8 It is assumed that this product will be used in system development and evaluation Moreover when used in Japan Electrical Appliance and Material Control Law and el...

Page 27: ...plied M2 x 6 mm screws in the four accessory holes of the MA and fasten the screws in opposite corners At that time use either the dedicated screwdriver that is supplied or a torque driver to fasten t...

Page 28: ...re 2 5 Connect the QB 78K0FX2L to the probe b Connection of emulation probe GND wire There are three GND wires in the emulation probe Connect them to the QB 78K0FX2L and target system 1 Fasten the GND...

Page 29: ...within the range of the two approximately 60 mm radius sections of the target system for connecting the emulation probe as shown in Figure 2 7 Figure 2 7 Where GND Wire Can Be Connected c Ensuring iso...

Page 30: ...into a receptacle and plug the other side into the power supply connector on the rear of the QB 78K0FX2L For QB 78K0FX2L connector positions see Figure 2 8 Figure 2 8 Connector Positions 2 7 Switchin...

Page 31: ...EJ0100 Rev 1 00 Page 31 of 37 2012 05 18 CHAPTER 3 SETTINGS AT PRODUCT SHIPMENT Table 3 1 Settings at Shipment Item Setting Remarks OSC1 Not mounted Oscillator can be mounted Note Power switch Set to...

Page 32: ...quently the operation clock frequency when the target device is mounted in the target system may differ from the operation clock frequency when the QB 78K0FX2L is connected Pin characteristics The pin...

Page 33: ...k pull down resistor The RESET pin of IECUBE is connected to a 2 M pull down resistor The ports except the shared analog pins of IECUBE are connected to 56 damping resistors The shared analog port pin...

Page 34: ...e potential as the target device to the clock pins X2 XT2 A watchdog timer reset A watchdog timer reset is not generated when an area for which the capacities of the internal ROM internal high speed R...

Page 35: ...QB 78K0FX2L In Circuit Emulator User s Manual Publication Date May 18th 2012 Rev 1 00 Published by Renesas Electronics Corporation...

Page 36: ...204 205 AZIA Center No 1233 Lujiazui Ring Rd Pudong District Shanghai 200120 China Tel 86 21 5877 1818 Fax 86 21 6887 7858 7898 Renesas Electronics Hong Kong Limited Unit 1601 1613 16 F Tower 2 Grand...

Page 37: ...R20UT2057EJ0100 QB 78K0FX2L In Circuit Emulator User s Manual...

Reviews: