background image

M301N2T-PRB User’s Manual 

5. Troubleshooting   

REJ10J0037-0100 Rev.1.00 Mar.16, 2005 

 

Page 44 of 48 

 
 

5.3 How to Request for Support 

After checking the items in "5 Troubleshooting", fill in the text file the installer of the emulator debugger generates in the 
following directory and email to your local distributor. 
 
\SUPPORT\product-name\SUPPORT.TXT 
 
For prompt response, please specify the following information: 
(1) Operating 

environment 

-  Operating voltage: 

       [V] 

-  Operating frequency: 

       [MHz] 

-  Operating mode: 

Single-chip, memory expansion, or microprocessor mode 

-  Clock supply to the MCU: 

Internal oscillator/External oscillator 

(2) Condition 

-  The emulator debugger starts up/does not start up 
-  The error is detected/not detected in the self-check 

Frequency 

of 

errors: 

always/frequency 

   ) 

(3) Problem 

Summary of Contents for Pod probe for M16C/1N Group M301N2T-PRB

Page 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Page 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Page 3: ...M301N2T PRB User s Manual User s Manual Rev 1 00 2005 03 Pod probe for M16C 1N Group...

Page 4: ...l inaccuracies or typographical errors Renesas Technology Corp assumes no responsibility for any damage liability or other loss rising from these inaccuracies or errors Please also pay attention to in...

Page 5: ...All the components of this product are shown in 1 1 Package components page 12 If there is any question or doubt about this product contact your local distributor The related manuals for using this pr...

Page 6: ...in your program development and evaluation stages In mass producing your program you have finished developing be sure to make a judgment on your own risk that it can be put to practical use by perfor...

Page 7: ...tantly making efforts to improve the design and performance of this emulator Therefore the specification or design of this emulator or its user s manual may be changed without prior notice About the r...

Page 8: ...an imminently dangerous situation that will cause death or heavy wound unless it is avoided However there are no instances of such danger for the product presented in this user s manual WARNING WARNIN...

Page 9: ...at a reliable ground connection is maintained If you smell a strange odor hear an unusual sound or see smoke coming from this product then disconnect power immediately by unplugging the AC power cable...

Page 10: ...ling This Product Use caution when handling the main unit Be careful not to apply a mechanical shock Do not touch the connector pins of the emulator main unit and the target MCU connector pins Static...

Page 11: ...cuit Board 18 2 1 3 Using the Oscillator Circuit on the User System 18 2 2 Switch Settings 20 2 3 A D and D A Conversion Bypass Capacitors 21 2 4 Connection the M30100T3 RPD E 22 2 5 Connecting the Us...

Page 12: ...ting Up the Emulator Debugger 37 Note on Stack Area 37 Note on MAP References and Settings 37 Note on Operation When Not Executing the User Program 37 Note on Making an MCU File 37 Notes on Address Ma...

Page 13: ...lyzes contents of communication with the emulator debugger and controls the emulator hardware This program is installed in the flash memory in the emulator main unit This program is downloadable from...

Page 14: ...use at a later time when sending your product for repair or other purposes Always use these packing box and cushion material when transporting this product If there is any question or doubt about the...

Page 15: ...eparately available This emulation pod is for the M16C 10 Series MCUs 3 Emulator main unit PC4701 separately available This is a PC4701 series emulator main unit excluding PC4701L and PC4700L 4 Pitch...

Page 16: ...initions of the system status LEDs Name Status Meaning ON Emulator system power supply is turned ON POWER OFF Emulator system power supply is turned OFF ON Emulator system is operating normally Flashi...

Page 17: ...OWER OFF Power is not supplied to the target MCU ON Target MCU clock is supplied CLOCK OFF Target MCU clock is not supplied ON Target MCU is being reset or reset signal of the user system is held low...

Page 18: ...ence setting Disassemble display C level debugging etc Real time trace function 32K cycle bus information recordable Bus external trigger time stamp 5 trace modes supported Break Before About After Fu...

Page 19: ...temperature 10 to 60 C no dew Table 1 7 Operating environment of the host machine Item Description Host machine IBM PC AT compatibles OS Windows 98 Windows 2000 Windows Me Windows XP CPU Pentium III...

Page 20: ...Supply The clock supply can be set in the Init dialog box when starting up the emulator debugger or inputting CLK command on the script window For pins XCIN XCOUT it is necessary to set the switches i...

Page 21: ...circuit shown in Figure 2 2 where a resonator is connected between pins XIN and XOUT oscillation does not occur because a flexible cable buffer IC and other devices are used between the evaluation MC...

Page 22: ...es and their factory settings Table 2 2 Switch settings of the FLX64 PRB Signal Switch Switch Setting of jumper switches PORT PORT XCIN XCIN JP1 P47 XCIN When using the P47 XCIN as a port Factory sett...

Page 23: ...e 2 4 shows the position of the bypass capacitor Figure 2 4 Foot patterns of bypass capacitors for A D converter IMPORTANT Note on the A D Converter Function The characteristics of an A D converter di...

Page 24: ...pod probe M301N2T PRB 1 Unscrew the two screws of the M301N2T PRB 2 Remove the M301N2T PRB from the FLX64 PRB In this time lift off the M301N2T PRB vertically Otherwise the connector may cause a break...

Page 25: ...2005 Page 23 of 48 2 5 Connecting the User System Connect the emulation pod to the user system as shown in Figure 2 7 Figure 2 7 Connecting the user system M30102T PTC Pod probe M301N2T PRB 48 pin 0...

Page 26: ...CK048SD are used for the HQPACK048SD do not use them for securing the YQPACK048SD 3 Connect the M30102T PTC along the YQ GUIDE s 4 Connect the M301N2T PRB Figure 2 8 Connecting the converter board M30...

Page 27: ...a internal RAM area internal ROM area firmware file name The contents of the MCU file when using the M301N2F8FP 3KB RAM 64KB ROM are as follows An example of a file name M301N2T3 MCU 0 SFR area Start...

Page 28: ...nd user system as simultaneously as possible 3 Do not leave either the emulator or user system powered on because of leakage current the internal circuits may be damaged 4 When turning on the power ag...

Page 29: ...urned on check the following 1 After powering on the PC4701 before starting up the emulator debugger Make sure that the oscillator circuit board is properly installed in the PC4701 and it is oscillati...

Page 30: ...ll start blinking 2 Start up the emulator debugger When the Init dialog box setup is complete the dialog which urges to download the firmware will appear Download the firmware following messages Requi...

Page 31: ...in the emulation pod FLX64 PRB to the factory settings as shown in Figure 3 4 4 Within 2 seconds of activating power to the emulator press the system reset switch on the emulator front panel 5 Check t...

Page 32: ...Whether the emulation pod and PC4701 are connected properly Whether the pod probe and emulation pod are connected properly Redownload the proper firmware Whether the switches in the M30100T3 RPD E an...

Page 33: ...SYSTEM RES ET POWER CLOCK RESET RU N HALT POWER SA F E ERROR S TA T US O F SYSTEM RESET POWER CLOCK RESET RUN HALT PO WER SAF E ERROR S T A T U S OF SYSTEM RESET PO WER CLOCK RESET RU N HAL T POWER S...

Page 34: ...is product 4 1 Target MCU Specifications Table 4 1 lists the specifications of target MCUs which can be debugged with this product Table 4 1 Specifications of target MCUs for the M301N2T PRB Item Desc...

Page 35: ...ion interrupt vector table addresses Although data can be downloaded to the DBC single step or BRK instruction interrupt vector table addresses be aware that because the emulator system uses this area...

Page 36: ...ulation pod If a maskable interrupt is requested when the user program is not being executed including when run time debugging is being performed the maskable interrupt request cannot be accepted beca...

Page 37: ...of the Converter Board M30102T PTC Figure 4 2 shows the external dimensions and a sample foot pattern of the converter board M30102T PTC for a 48 pin 0 5 mm pitch LQFP Sample foot pattern Unit mm Figu...

Page 38: ...he self check does not result normally excluding user system error the emulation pod or pod probe may be damaged Then contact your local distributor Be sure to disconnect the user system before execut...

Page 39: ...e details see 3 1 2 Setting the Work Area page 25 Set the work area as MAP INT Note on Stack Area With this product a maximum 7 bytes of the interrupt stack is consumed Therefore ensure the 7 bytes ma...

Page 40: ...cause communication errors Note on Watchdog Function The MCU s watchdog timer can be used only while programs are being executed To use it otherwise disable the watchdog timer Note on Protect Registe...

Page 41: ...Interrupt Vector Area Do not perform the below debugging operations with the single step interrupt vector area addresses FFFECh FFFEFh 1 Step execution of instructions that access the single step int...

Page 42: ...e power of PC4701 Not normal PC4701 Front panel LEDs 1 Check emulator system connections See 2 4 Connecting the M30100T3 RPD E page 22 2 Redownload the firmware See 3 3 Downloading Firmware page 28 3...

Page 43: ...STATUS OF TARGET does not light up Connected Check that power Vcc and GND is properly supplied to the user system Disconnected 1 Check that both the main sub clocks are not set to External in the emu...

Page 44: ...gger user s manual online manual 4 Check that the descriptions in the MCU file are correct See 3 1 1 Making an MCU File page 25 ERROR 16215 Cannot communicate with the debugging monitor Please execute...

Page 45: ...oper firmware See 3 3 Downloading Firmware page 28 3 Choose the proper MCU file in the Init dialog box See the emulator debugger user s manual online manual 4 Check that the descriptions in the MCU fi...

Page 46: ...to your local distributor SUPPORT product name SUPPORT TXT For prompt response please specify the following information 1 Operating environment Operating voltage V Operating frequency MHz Operating mo...

Page 47: ...isuse of it Fires earthquakes and other unexpected disasters In the above cases contact your local distributor If your product is being leased consult the leasing company or the owner 6 3 Repair Provi...

Page 48: ...should please send the faulty product along with the Repair Request Sheet to Renesas Solutions Corp Renesas Solutions When the faulty product is repaired it will be returned to the customer at the ear...

Page 49: ...on Date Mar 16 2005 Rev 1 00 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Microcomputer Tool Development Department Renesas Solutions Corp 2005 Renesas Technology Corp a...

Page 50: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan M301N2T PRB REJ10J0037 0100 T User s Manual...

Reviews: