5. Connection Procedure 

(See Figure 3)

 

 

The procedure for connecting the M3T-FLX-100NSD is shown 
below. 

 

(1)  Mount the NQPACK100SD-ND on the user system. 

(2)  Attach the YQPACK100SD on the NQPACK100SD-ND. 

(3) Secure the four corners of the YQPACK100SD with the 

YQ-GUIDE's. 

 

Do not use the screws included with the 

YQPACK100SD for fixing the YQPACK100SD. 

 

Do NOT used the screwdriver included with the 

NQPACK100SD-ND that is used only for the 

HQPACK100SD. 

(4)  Attach the M3T-FLX-100NSD on the YQPACK100SD. 

(5) Attach the probe of the emulation pod to the M3T-FLX-

100NSD. 

 

M3T-FLX-100NSD

YQ-GUIDE (x4)

YQPACK100SD

NQPACK100SD-ND

100-pin 0.5-mm-pitch

(100P6Q-A) foot pattern

(1)

(2)

(3)

(5)

Use a slotted screwdriver.

FLX100

(4)

: No. 1 pin
  Be sure to align the pins.

 

Figure 3 Connection procedure of the M3T-FLX-100NSD 
 

6. External Dimensions and a Sample Foot Pattern 

 

27.0

28.6

27

.0

12

.1

16

.5

0.25

0.5

13.0

17.0

13

.0

17

.0

Unit: mm

M3T-FLX-100NSD

J2

J1

1

1

50

50

25

25

26

26

REV.A  JAPAN

 