M3062PT2-EPB User’s Manual
3. Usage (How to Use the Emulator Debugger)
REJ10J0868-0200 Rev.2.00 January 16, 2006
3. Example Data Settings
Setting a break event
A1
Address 1 : 0020E8
Data 1
: 5423
MASK :
FFFF
Access :
WRITE
Setting a break event (using 2 events)
A1
A2
Address 1 : 0020E5
Address 1 : 0020E6
Data 1
: 7900
Data 1
: 00AB
MASK :
FF00 MASK :
00FF
Access :
WRITE
Access :
WRITE
Set the combinatorial events to AND.
Setting a break event
A1
Address 1 : 0020E2
Data 1
: 00E5
MASK :
00FF
Access :
WRITE
Setting events for wordwise accesses to the even-addresses
STE.W A0,20E8h(A0=5423h)
High-order and low-order data effective
Setting events for wordwise accesses to the odd-addresses
STE.W A0,20E5h(A0=AB79h)
Odd-address high-order data effective
Even-address low-order data effective
Setting events for wordwise accesses to the even-addresses
STE.B R0L,[A1A0](R0L=E5h,A1=0000h,A0=20E2h)
Low-order data effective
Setting events for wordwise accesses to the odd-addresses
STE.B R0L,[A1A0](R0L=E6h,A1=0000h,A0=20E3h)
High-order data effective
Setting a break event
A1
Address 1 : 0020E3
Data 1
: E600
MASK :
FF00
Access :
WRITE
Page 65 of 102
Summary of Contents for M16C/30P