background image

Cautions 

1.  Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s 

patent, copyright, trademark, or other intellectual property rights for information contained in 
this document.  Renesas bears no responsibility for problems that may arise with third party’s 
rights, including intellectual property rights, in connection with use of the information contained 
in this document. 

2.  Products and product specifications may be subject to change without notice. Confirm that you 

have received the latest product standards or specifications before final design, purchase or use. 

3.  Renesas makes every attempt to ensure that its products are of high quality and reliability. 

However, contact Renesas’s sales office before using the product in an application that demands 
especially high quality and reliability or where its failure or malfunction may directly threaten 
human life or cause risk of bodily injury, such as aerospace, aeronautics, nuclear power, 
combustion control, transportation, traffic, safety equipment or medical equipment for life 
support. 

4.  Design your application so that the product is used within the ranges guaranteed by Renesas 

particularly for maximum rating, operating supply voltage range, heat radiation characteristics, 
installation conditions and other characteristics.  Renesas bears no responsibility for failure or 
damage when used beyond the guaranteed ranges.  Even within the guaranteed ranges, consider 
normally foreseeable failure rates or failure modes in semiconductor devices and employ 
systemic measures such as fail-safes, so that the equipment incorporating Renesas product does 
not cause bodily injury, fire or other consequential damage due to operation of the Renesas 
product. 

5.  This product is not designed to be radiation resistant. 

6.  No one is permitted to reproduce or duplicate, in any form, the whole or part of this document 

without written approval from Renesas. 

7.  Contact Renesas’s sales office for any questions regarding this document or Renesas 

semiconductor products. 

 

 

Summary of Contents for H8S/2328 Series

Page 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Page 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Page 3: ...H8S 2328 Series TFP 120 User System Interface Cable HS2328ECN61H for E6000 Emulator User s Manual User s Manual Rev 2 0 2003 04...

Page 4: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Page 5: ...s s original microcomputer H8S 2328 series The HS2328ECN61H is a user system interface cable that connects an H8S 2328 series E6000 emulator HS2338EPI61H or HS2339EPI61H hereinafter referred to as the...

Page 6: ...IC Socket 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 6 2 2 5 Fastening Cable Body 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimensions for...

Page 7: ...cket manufactured by YAMAICHI ELECTRONICS Co Ltd for the TFP 120 package IC socket on the user system Figure 1 shows the configuration of the HS2328ECN61H user system interface cable for the TFP 120 p...

Page 8: ...ty Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the TFP 120 package 4 Socket cover 1 For installing an TFP 120 packaged MCU 5 Screws M2 x 12 mm 4 For fastening cable head with fo...

Page 9: ...ke sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instruction...

Page 10: ...Figure 2 Connecting User System Interface Cable to Emulator Station 4...

Page 11: ...ult in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the I...

Page 12: ...greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 3 If the emulato...

Page 13: ...Figure 4 Connecting User System Interface Cable to User System 7...

Page 14: ...2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 5 Fastening Cable Body 8...

Page 15: ...an IC socket for an TFP 120 package IC149 120 043 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 6 are somewhat different from those of the actual chip s mount pad...

Page 16: ...2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7 Figure 7 Dimensions for User System Interface Cable Head 10...

Page 17: ...necting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 8 Figure 8 Resulting Dimensions after Connecti...

Page 18: ...d may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a test...

Page 19: ...Figure 9 Installing MCU to User System 13...

Page 20: ...l clock on the user system For details refer to the Emulator Supplementary Information HS2338EPI61HE and HS2339EPI61HE To use the emulator internal clock Select the clock in the emulator station as th...

Page 21: ...s Do not use this cable with any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable 5 While the emulat...

Reviews: