Emulator station

Cable body connector

Screws for fixing
the cable body

User system interface cable

E6000

 

Figure 2   Connecting User System Interface Cable to Emulator Station 

 

Summary of Contents for H8S/2218 Series

Page 1: ...system interface cable must only be used for the above purpose Improvement Policy Renesas Technology Corp including its subsidiaries hereafter collectively referred to as Renesas pursues a policy of c...

Page 2: ...rom you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED H...

Page 3: ...t may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Renesas s prior written consent Other Important Things to Keep in Mind 1 Circuitry an...

Page 4: ...this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potenti...

Page 5: ...PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000 emulator an...

Page 6: ...H8S 2218 Series TFP 100G User System Interface Cable HS2218ECN61H for E6000 Emulator User s Manual ADE xxx xxx Rev 2 0 7 22 03 Renesas Technology Corp...

Page 7: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Page 8: ...s a user system interface cable that connects an H8S 2214 series E6000 emulator HS2214EPI62H hereinafter referred to as the emulator to the IC socket for a TFP 100G package for the H8S 2218 series MCU...

Page 9: ...Soldering IC Socket 6 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 7 2 2 5 Fastening Cable Body 9 2 3 Recommended Dimensions for User System Mount Pad 10 2 4 Dimensions for User System Inte...

Page 10: ...em Figure 1 shows the configuration of the HS2218ECN61H user system interface cable for the TFP 100G package To emulator station Cable body EIO board Screws M3 x 6 mm for fixing the cable body Screws...

Page 11: ...two printed circuit boards 3 IC socket 1 For the TFP 100G package 4 Socket cover 1 For installing a TFP 100G packaged MCU 5 Screws M2 x 10 mm 4 For fastening cable head 6 Screws M2 x 6 mm 4 For instal...

Page 12: ...terface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instructions below 1 Make sure the user system and emulator station are turned off CAU...

Page 13: ...Emulator station Cable body connector Screws for fixing the cable body User system interface cable E 6 0 0 0 Figure 2 Connecting User System Interface Cable to Emulator Station 4...

Page 14: ...mulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the...

Page 15: ...ckage to the user system Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets Use slightly more solder than the MCU 2 2 3 Inserting Cable Head...

Page 16: ...crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Fasten the u...

Page 17: ...Pin 1 Cable head IC socket NQPACK100SE manufactured by Tokyo Eletech Corporation Screws M2 x 10 mm User system Figure 4 Connecting User System Interface Cable to User System 8...

Page 18: ...2 2 5 Fastening Cable Body Connect the cable body to the cable head 9 Cable body Cable head Remove jig Push the remove jig User system Removing Figure 5 Fastening Cable Body...

Page 19: ...with an IC socket for a TFP 100G package NQPACK100SE manufactured by Tokyo Eletech Corporation Note that the dimensions in figure 6 are somewhat different from those of the actual chip s mount pad Uni...

Page 20: ...r System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7 Unit mm Tolerance 0 5 mm 63 5 63 5 21 3 21 3 21 0 21 0 Figure 7 Dimensions for User System I...

Page 21: ...after connecting the user system interface cable head to the user system are shown in figure 8 Cable head User system Unit mm Tolerance 0 5 mm IC socket NQPACK100SE manufactured by Tokyo Eletech Corpo...

Page 22: ...screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction wi...

Page 23: ...14 Socket cover MCU Pin 1 IC socket NQPACK100SE manufactured by Tokyo Eletech Corporation User system Screws M2 x 6 mm Figure 9 Installing MCU to User System...

Page 24: ...interface circuit as shown in figure 10 15 H8S 2218 0 1 F QS3384 5 0 1 F DrVcc DrVss D15 to D8 47 47 47 k 47 k Vcc Vcc Vcc Vcc D15 PD7 D8 PD0 P72 TMO0 CS6 to D15 PD7 D8 PD0 to Evaluation chip E6000 e...

Page 25: ...Properties dialog box To use the external clock on the user system Select external clock target or target 2 with the CLOCK option in the Configuration Properties dialog box and supply the external clo...

Page 26: ...heavy or sharp metal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable...

Page 27: ...ection 6 Bus Controller and section 14 Universal Serial Bus USB in the H8S 2218 Series Hardware Manual When using the emulator the following register settings are required Modes 6 and 7 in the H8S 221...