background image

Section 5   Notice 

1.  Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable 

head before inserting the cable head into the user system IC socket. 

2.  The dimensions of the recommended mount pad for the user system IC socket are different from 

those of the MCU.   

3.  This user system interface cable is specifically designed for the HS2148EPI61H emulator.  Do 

not use this cable with any other emulator station.   

4.  To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the 

user system interface cable. 

5.  While the emulator station is connected to the user system with the user system interface cable, 

force must not be applied to the cable head.  Place the emulator station, user system interface 
cable, and user system as shown in the example in figure 10. 

 

User system

Cable

Emulator station

Place components so that the cable body and cable head are 
parallel to the user system.

Cable head is parallel 

to emulator station

Cable head is parallel 

to user system

Figure 10   User System Interface Cable Location Example 

6.  The JP1 short connector is used for testing.  Do not remove the short pins that are inserted in the 

sides of pin 1 and pin 2. 

JP1

 

Figure 11  JP1 Short Connector 

15 

 

Summary of Contents for H8S/2138 Series

Page 1: ...H8S 2138 Series TQFP 80C User System Interface Cable HS2138ECN61H for E6000 Emulator User s Manual HS2138ECN61HE C...

Page 2: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Page 3: ...microcomputer H8S 2138 series The HS2138ECN61H is a user system interface cable that connects an H8S 2148 H8S 2138 H8S 2128 series E6000 emulator HS2148EPI61H hereinafter referred to as the emulator...

Page 4: ...et 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 5 2 2 4 Fastening Cable Head 6 2 2 5 Connecting Cable Body to Cable Head 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimens...

Page 5: ...Use an IC149 080 058 B51 socket manufactured by YAMAICHI ELECTRONICS Co Ltd for the TFP 80C package IC socket on the user system Figure 1 shows the configuration of the HS2138ECN61H user system interf...

Page 6: ...g cable head User system IC socket Cable head Screws M2 6 x 12 mm with flat washers Screws M2 6 x 8 mm with flat washers Socket cover To emulator station Cable body Figure 1 HS2138ECN61H User System I...

Page 7: ...arks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the TFP 80C package 4 Socket cover 1 For installing an TFP 80C packaged MCU 5 Screws M2 6 x 12 mm 4 For fastening cable head wi...

Page 8: ...age the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable body to the emulator station follow the instructions below 1 Make sure...

Page 9: ...e location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for an TFP 80C package and fasten it to the user system before soldering 2 2 2 Soldering IC Socket After...

Page 10: ...a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Fasten th...

Page 11: ...Cable head User system IC socket IC149 080 058 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Screws M2 6 x 12 mm flat washer Pin 1 Figure 3 Connecting User System Interface Cable to User System 7...

Page 12: ...2 2 5 Connecting Cable Body to Cable Head Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8...

Page 13: ...th an IC socket for an TFP 80C package IC149 080 058 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount p...

Page 14: ...ensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Unit mm Tolerance 0 5 mm Figure 6 Dimensions for User System Interface Cable...

Page 15: ...after connecting the user system interface cable head to the user system are shown in figure 7 Cable head User system Unit mm Tolerance 0 5 mm IC socket IC149 080 058 B51 manufactured by YAMAICHI ELE...

Page 16: ...head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a...

Page 17: ...MCU Pin 1 IC socket IC149 080 058 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 6 x 8 mm with flat washers Socket cover Figure 8 Installing MCU to User System 13...

Page 18: ...l clock and an external clock on the user system For details refer to the H8S series E6000 Emulator User s Manual HS2000EPI61HE To use the emulator internal clock Select the clock in the emulator stat...

Page 19: ...tal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the e...