background image

2.2 

Connecting User System Interface Cable to User System 

WARNING

 

   

Always switch OFF the user system and the emulator  

  product before the USER SYSTEM INTERFACE CABLE  
  is connected to or removed from any part.  Before connecting,  
  make sure that pin 1 on both sides are correctly aligned.  Failure to  
  do so will damage the user system and the emulator product or will  
  result in PERSONAL INJURY.  The USER PROGRAM will be  
  LOST. 

To connect the cable head to the user system, follow the instructions below. 

2.2.1 

Installing IC Socket 

After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of 
the IC socket for an FP-80A package, and fasten it to the user system before soldering. 

2.2.2 

Soldering IC Socket 

After fastening, solder the IC socket for an FP-80A package to the user system.  Be sure to 
completely solder the leads so that the solder slops gently over the leads and forms solder fillets.  
(Use slightly more solder than the MCU.)   

2.2.3 

Inserting Cable Head 

CAUTION

 

   

Check the location of pin 1 before inserting. 

 

Align pin 1 on the IC socket for an FP-80A package on the user system with pin 1 on the user system 
interface cable head, and insert the user system interface cable head into the IC socket on the user 
system, as shown in figure 3.  

 

Summary of Contents for H8/3864 Series

Page 1: ...H8 3864 Series QFP 80A User System Interface Cable HS3864ECH61H for E6000 Emulator User s Manual HS3864ECH61HE D ...

Page 2: ...of bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the product is used within the ranges guaranteed by Renesas particularly for maximum rating operating supply voltage range heat radiation characteristics installation conditions and other characteristics Rene...

Page 3: ...ocomputer H8 3864 series and H8 3887 series The HS3864ECH61H is a user system interface cable that connects an H8 3864 series H8 3887 series E6000 emulator HS3880EPI60H hereinafter referred to as the emulator to the IC socket for a QFP 80A package package code FP 80A for the H8 3864 series MCU on the user system ...

Page 4: ...ket 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 5 2 2 4 Fastening Cable Head 6 2 2 5 Connecting Cable Body to Cable Head 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimensions for User System Interface Cable Head 10 2 5 Resulting Dimensions after Connecting User System Interface Cable 11 Section 3 Installing the MCU to the User System 12 Section 4 Verifying Operation ...

Page 5: ...CA Use an IC149 080 017 B5 socket manufactured by YAMAICHI ELECTRONICS Co Ltd for the FP 80A package IC socket on the user system Figure 1 shows the configuration of the HS3864ECH61H user system interface cable for the FP 80A package ...

Page 6: ... IC socket Cable head Screws M2 x 12 mm with flat washers Screws M2 x 8 mm with flat washers Socket cover for fastening cable head To emulator station Cable body Figure 1 HS3864ECH61H User System Interface Cable 2 ...

Page 7: ...ent Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP 80A package 4 Socket cover 1 For installing an FP 80A packaged MCU 5 Screws M2 x 12 mm 4 For fastening cable head 6 Screws M2 x 8 mm 4 For installing an FP 80A packaged MCU with four flat washers 7 Documentation 1 User s manual for HS3864ECH61H this manual ...

Page 8: ...mage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable body to the emulator station follow the instructions below 1 Make sure the user system and emulator station are turned off 2 After making sure the direction of the cable body connector is correct firmly insert the cable body connector into the emulator station socket f...

Page 9: ... the location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for an FP 80A package and fasten it to the user system before soldering 2 2 2 Soldering IC Socket After fastening solder the IC socket for an FP 80A package to the user system Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets Use slightly mo...

Page 10: ...tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC soc...

Page 11: ...nating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components User system Pin 1 Cable head IC socket IC149 080 017 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Screws M2 x 12 mm with flat washers Figure 3 Connecting User System Interface...

Page 12: ...2 2 5 Connecting Cable Body to Cable Head Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8 ...

Page 13: ...th an IC socket for an FP 80A package IC149 080 017 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pad 9 Unit mm 0 35 0 65 19 12 35 0 1 0 1 0 05 0 65 0 05 0 65 19 12 35 0 1 14 70 max 20 50 min 0 65 0 05 Figure 5 Recommended Dimensions for Mount Pad ...

Page 14: ...mensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Unit mm Tolerance 0 5 mm Figure 6 Dimensions for User System Interface Cable Head 10 ...

Page 15: ...ns after connecting the user system interface cable head to the user system are shown in figure 7 Cable head User system Unit mm Tolerance 0 5 mm IC socket IC149 080 017 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11 ...

Page 16: ...rew head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Check the location of pin 1 before inserting the MCU into the IC socket on the user system as shown in figure 8 After inserting the MCU fasten the so...

Page 17: ...MCU Pin 1 IC socket IC149 080 017 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 x 8 mm with flat washers Socket cover Figure 8 Installing MCU to User System 13 ...

Page 18: ...mulator command To use the external clock on the user system as the system clock Select target clock t2 with the CLOCK command emulator command Supply the external clock from the user system to the emulator When a crystal oscillator is inserted into the OSC1 and OSC2 terminals for the system clock the colck is generated by the oscillator circuits shown in figure 9 To input an external clock from t...

Page 19: ... input specifications 15 R2 270 R1 1 M HCU04 HCU04 To E6000 emulator OSC1 OSC2 System clock oscillator Ω Ω 0 8 Vcc 55 ns max 55 ns max 0 8 Vcc 0 3 Vcc 0 V Vcc Vcc User System Vcc 1 8 to 5 5 V 0 3 Vcc Subclock input specifications Figure 9 System Clock Oscillator and Subclock Input Specifications ...

Page 20: ...etal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the emulator station user system interface cable and user system as shown in the example in figure 10 User system Cable Emulator station Place components so that the cable body and cable head are parallel...

Reviews: