Renesas H8/329 Series User Manual Download Page 4

Cautions 

1.  Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s 

patent, copyright, trademark, or other intellectual property rights for information contained in 
this document.  Renesas bears no responsibility for problems that may arise with third party’s 
rights, including intellectual property rights, in connection with use of the information 
contained in this document. 

2.  Products and product specifications may be subject to change without notice. Confirm that you 

have received the latest product standards or specifications before final design, purchase or 
use. 

3.  Renesas makes every attempt to ensure that its products are of high quality and reliability. 

However, contact Renesas’s sales office before using the product in an application that 
demands especially high quality and reliability or where its failure or malfunction may directly 
threaten human life or cause risk of bodily injury, such as aerospace, aeronautics, nuclear 
power, combustion control, transportation, traffic, safety equipment or medical equipment for 
life support. 

4.  Design your application so that the product is used within the ranges guaranteed by Renesas 

particularly for maximum rating, operating supply voltage range, heat radiation characteristics, 
installation conditions and other characteristics.  Renesas bears no responsibility for failure or 
damage when used beyond the guaranteed ranges.  Even within the guaranteed ranges, 
consider normally foreseeable failure rates or failure modes in semiconductor devices and 
employ systemic measures such as fail-safes, so that the equipment incorporating Renesas 
product does not cause bodily injury, fire or other consequential damage due to operation of 
the Renesas product. 

5.  This product is not designed to be radiation resistant. 

6.  No one is permitted to reproduce or duplicate, in any form, the whole or part of this document 

without written approval from Renesas. 

7.  Contact Renesas’s sales office for any questions regarding this document or Renesas 

semiconductor products. 

 

 

Summary of Contents for H8/329 Series

Page 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Page 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Page 3: ...H8 3297 Series H8 329 Series QFP 64A User System Interface Cable HS3297ECH61H for E6000 Emulator User s Manual User s Manual...

Page 4: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Page 5: ...essor H8 300 series The HS3297ECH61H is a user system interface cable that connects an H8 300 series E6000 emulator HS3008EPI60H hereinafter referred to as the emulator to the IC socket for a QFP 64A...

Page 6: ...et 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 5 2 2 4 Fastening Cable Head 6 2 2 5 Connecting Cable Body to Cable Head 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimens...

Page 7: ...A Use an IC149 064 008 B5 socket manufactured by YAMAICHI ELECTRONICS Co Ltd for the FP 64A package IC socket on the user system Figure 1 shows the configuration of the HS3297ECH61H user system interf...

Page 8: ...2 Screws M2 0 x 12 mm IC socket Cable head User system Socket cover Screws M2 0 x 8 mm and flat washers and flat washers For fastening cable head Figure 1 HS3297ECH61H User System Interface Cable...

Page 9: ...marks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP 64A package 4 Socket cover 1 For installing an FP 64A packaged MCU 5 Screws M2 0 x 12 mm 4 For fastening cable head wit...

Page 10: ...aligned Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable body to the emulator station follow t...

Page 11: ...the location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for an FP 64A package and fasten it to the user system before soldering 2 2 2 Soldering IC Socket After...

Page 12: ...be caused by a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necess...

Page 13: ...crews M2 0 x 12 mm and flat washers Cable head Pin 1 IC socket IC149 064 008 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Figure 3 Connecting User System Interface Cable to User System 7...

Page 14: ...2 2 5 Connecting Cable Body to Cable Head Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8...

Page 15: ...IC socket for an FP 64A package IC149 064 008 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pad 9 Uni...

Page 16: ...2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Figure 6 Dimensions for User System Interface Cable Head 10...

Page 17: ...ions after connecting the user system interface cable head to the user system are shown in figure 7 9 4 Unit mm Tolerance 0 5 mm User system IC socket IC149 064 008 B5 manufactured by YAMAICHI ELECTRO...

Page 18: ...uch the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check condu...

Page 19: ...MCU Pin 1 mark User system Socket cover IC socket IC149 064 008 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Figure 8 Installing MCU to User System 13...

Page 20: ...H8 300 Series E6000 Emulator User s Manual HS3008EPI60HE To use the emulator internal clock Select the clock in the emulator station as the system clock by using the CLOCK command emulator command To...

Page 21: ...ith any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable 5 While the emulator station is connected t...

Reviews: