Section 5   Notice 

1.  Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable 

head before inserting the cable head into the user system IC socket. 

2.  The dimensions of the recommended mount pad for the user system IC socket are different 

from those of the MCU.   

3.  This user system interface cable is specifically designed for the HS3052EPI61H emulator.  Do 

not use this cable with any other emulator station.   

4.  To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on 

the user system interface cable. 

5.  While the emulator station is connected to the user system with the user system interface 

cable, force must not be applied to the cable head.  Place the emulator station, user system 
interface cable, and user system as shown in the example in figure 10. 

 

Figure 10   User System Interface Cable Location Example 

6.  The JP1 jumper is used for testing.  Do not remove the jumper pin that is inserted in the sides 

of pin 1 and pin 2. 

JP1

1

3

 

Figure 11  JP1 Jumper 

16 

 

Summary of Contents for H8/3001 TFP-80C

Page 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Page 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Page 3: ...H8 3001 TFP 80C User System Interface Cable HS3001ECN61H for E6000 Emulator User s Manual User s Manual...

Page 4: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Page 5: ...CN61H for the Renesas s original microprocessor H8 3001 The HS3001ECN61H is a user system interface cable that connects an H8 3052 series E6000 emulator HS3052EPI61H hereinafter referred to as the emu...

Page 6: ...IC Socket 6 2 2 2 Soldering IC Socket 6 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 7 2 2 5 Fastening Cable Body 9 2 3 Recommended Dimensions for User System Mount Pad 10 2 4 Dimensions fo...

Page 7: ...Use an IC149 080 058 B51 socket manufactured by YAMAICHI ELECTRONICS Co Ltd for the TFP 80C package IC socket on the user system Figure 1 shows the configuration of the HS3001ECN61H user system interf...

Page 8: ...Figure 1 HS3001ECN61H User System Interface Cable 2...

Page 9: ...Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the TFP 80C package 4 Socket cover 1 For installing an TFP 80C packaged MCU 5 Screws M2 6 x 12 mm 4 For fastening cable head with fo...

Page 10: ...he emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned 2 The user system interfa...

Page 11: ...Figure 2 Connecting User System Interface Cable to Emulator Station 5...

Page 12: ...the location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for a TFP 80C package and fasten it to the user system before soldering 2 2 2 Soldering IC Socket After...

Page 13: ...by a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Fasten...

Page 14: ...n 1 Cable head IC socket IC149 080 058 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Screws M2 6 x 12 mm with flat washers User system Figure 3 Connecting User System Interface Cable to User System...

Page 15: ...2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 9...

Page 16: ...th an IC socket for a TFP 80C package IC149 080 058 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pa...

Page 17: ...ser System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 45 7 48 6 4 0 4 2 2 63 5 63 5 17 4 17 4 29 0 29 0 Figure 6 Dimensions for User System Inte...

Page 18: ...necting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 7 Figure 7 Resulting Dimensions after Connecti...

Page 19: ...rew head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with...

Page 20: ...MCU Pin 1 IC socket IC149 080 058 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 6 x 8 mm with flat washers Socket cover Figure 8 Installing MCU to User System 14...

Page 21: ...8 3052 Series E6000 Emulator User s Manual HS3052EPI61HE To use the emulator internal clock Select the clock in the emulator station as the system clock by using the CLOCK command emulator command To...

Page 22: ...th any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable 5 While the emulator station is connected to...

Reviews: