background image

18 

 

6.  The P1 short connector is used for testing. Do not remove the inserted jumper pin. 

P1

1

3

 

Figure 12   P1 Short Connector 

Summary of Contents for FP-32A

Page 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Page 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Page 3: ...H8 36902 Group FP 32A User System Interface Cable HS36902ECH61H User s Manual User s Manual Rev 1 00 2005 07 Renesas Microcomputer Development Environment System H8 Family H8 300H Tiny Series HS36902...

Page 4: ......

Page 5: ...fore making a final decision on the applicability of the information and products Renesas Technology Corp assumes no responsibility for any damage liability or other loss resulting from the informatio...

Page 6: ......

Page 7: ...system interface cable must only be used for the above purpose Improvement Policy Renesas Technology Corp including its subsidiaries hereafter collectively referred to as Renesas pursues a policy of...

Page 8: ...om you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED HE...

Page 9: ...rt may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Renesas prior written consent Other Important Things to Keep in Mind 1 Circuitry and...

Page 10: ...low this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a pote...

Page 11: ...in PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000 emulator...

Page 12: ...VI...

Page 13: ...microcomputer H8 36912 H8 36902 group The HS36902ECH61H is a user system interface cable that connects an H8 36912 H8 36902 group E6000 emulator HS3664EPI61H or HS3664EPI62H hereinafter referred to as...

Page 14: ...1 Installing IC Socket 6 2 2 2 Inserting Cable Head 7 2 2 3 Fastening Cable Head 7 2 2 4 Fastening Cable Body 9 2 3 Recommended Dimensions for User System Mount Pad 10 2 4 Dimensions for User System...

Page 15: ...em Figure 1 shows the configuration of the HS36902ECH61H user system interface cable for the FP 32A package User system IC socket Cable head Screws M2 x 10 mm for fastening cable head Screws M2 x 6 mm...

Page 16: ...IC socket 1 For the FP 32A package 4 Socket cover 1 For installing an FP 32A packaged MCU 5 Screws M2 x 10 mm 4 For fastening cable head 6 Screws M2 x 6 mm 4 For installing an FP 32A packaged MCU 7 C...

Page 17: ...e USER SYSTEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emu...

Page 18: ...4 E 6 0 0 0 Emulator station User system interface cable CTS screws M3 x 6 mm Cable body connector Figure 2 Connecting User System Interface Cable to Emulator Station...

Page 19: ...BLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned Failure to do so will result in a FIRE HAZARD and will damage the user system an...

Page 20: ...ections at the bottom of the IC socket and fasten it to the user system Use the guide pins provided to determine where to install the IC socket as shown in figure 3 User system IC socket NQPACK032SA m...

Page 21: ...system as shown in figure 4 2 2 3 Fastening Cable Head CAUTION 1 Use the screwdriver provided for tightening screws 2 The tightening torque must be 0 098 N m or less If the applied torque cannot be ac...

Page 22: ...rnating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or...

Page 23: ...9 2 2 4 Fastening Cable Body Connect the cable body to the cable head Cable head Remove jig User system Push the unfastening jigs Removing Cable body Figure 5 Fastening Cable Body...

Page 24: ...tem with an IC socket for an FP 32A package NQPACK032SA manufactured by Tokyo Eletech Corporation Note that the dimensions in figure 6 are somewhat different from those of the actual chip s mount pad...

Page 25: ...User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7 Unit mm Tolerance 0 5 mm 76 2 66 0 24 6 16 7 29 7 16 7 Figure 7 Dimensions for User Syste...

Page 26: ...ns after connecting the user system interface cable head to the user system are shown in figure 8 19 7 29 2 IC socket NQPACK032SA manufactured by Tokyo Eletech Corporation Cable head User system Unit...

Page 27: ...screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction wi...

Page 28: ...14 MCU Pin 1 IC socket NQPACK032SA manufactured by Tokyo Eleteck Corporation User system Screws M2 x 6 mm Socket cover Figure 9 Installing MCU to User System...

Page 29: ...e OSC1 tarminal on the cable head or connecting a crystal oscillator to the OSC1 and OSC2 terminals When a crystal oscillator is inserted into the OSC1 and OSC2 terminals for the system clock the cloc...

Page 30: ...the subclock input specifications R2 270 R1 1 M HCU04 HCU04 To E6000 emulator To E6000 emulator OSC1 OSC2 System clock oscillator Subclock oscillator R6 470 k R5 3 3 M HCU04 HCU04 HCU04 HCU04 X1 X2 R...

Page 31: ...tor station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable 5 While the emulator station is connected to the user system w...

Page 32: ...18 6 The P1 short connector is used for testing Do not remove the inserted jumper pin P1 1 3 Figure 12 P1 Short Connector...

Page 33: ...ectively when they are used as OSC1 and OSC2 Turn SW1 and SW2 to the PC0 and PC1 sides respectively when they are used as PC0 and PC1 At shipment SW1 and SW2 are turned to the OSC1 and OSC2 sides The...

Page 34: ...20...

Page 35: ...System Interface Cable HS36902ECH61H Publication Date Rev 1 00 June 22 2005 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Technical Documentation Information Department...

Page 36: ...Fax 44 1628 585 900 Renesas Technology Hong Kong Ltd 7th Floor North Tower World Finance Centre Harbour City 1 Canton Road Tsimshatsui Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2730 6071 Renesas Tec...

Page 37: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan H8 36912 H8 36902 Group FP 32A REJ10B0198 0100 User System Interface Cable HS36902ECH61H User s Manual...