Preface 

Thank you for purchasing this user system interface cable (HS2318ECH61H) for the Renesas’s 
original microcomputer H8/2318 series. 

The HS2318ECH61H is a user system interface cable that connects an H8/2318 series E6000 
emulator (HS2338EPI61H; hereinafter referred to as the emulator) to the IC socket for a 
FP-100B/TFP-100B package for the H8S/2318 series MCU on the user system. 

 

Summary of Contents for FP-100B

Page 1: ...H8 2318 Series FP 100B TFP 100B User System Interface Cable HS2318ECH61H for E6000 Emulator User s Manual Rev 2 0 4 1 03 Renesas Technology Corp HS2318ECH61HE B...

Page 2: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Page 3: ...nesas s original microcomputer H8 2318 series The HS2318ECH61H is a user system interface cable that connects an H8 2318 series E6000 emulator HS2338EPI61H hereinafter referred to as the emulator to t...

Page 4: ...IC Socket 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 6 2 2 5 Fastening Cable Body 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimensions for...

Page 5: ...factured by YAMAICHI ELECTRONICS Co Ltd for the FP 100B TFP 100B package IC socket on the user system Figure 1 shows the configuration of the HS2318ECH61H user system interface cable for the FP 100B T...

Page 6: ...ble body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP 100B TFP 100B package 4 Socket cover 1 For installing an FP 100B TFP 100B packaged MCU 5 Screws M2 6 x 12 mm 4 For fastening cable head wi...

Page 7: ...ke sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instruction...

Page 8: ...Figure 2 Connecting User System Interface Cable to Emulator Station 4...

Page 9: ...SONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the IC socket a...

Page 10: ...pe screwdriver whose head matches the screw head 2 The tightening torque must be 0 294 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn t...

Page 11: ...vided Each screw should be tightened a little at a time alternating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered I...

Page 12: ...2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jigs Removing User system Figure 4 Fastening Cable Body 8...

Page 13: ...IC socket for an FP 100B TFP 100B package IC149 100 054 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mou...

Page 14: ...r System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Unit mm Tolerance 0 5 mm 63 5 63 5 16 5 16 0 29 0 29 0 Figure 6 Dimensions for User System I...

Page 15: ...necting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 7 Figure 7 Resulting Dimensions after Connecti...

Page 16: ...head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a...

Page 17: ...Figure 8 Installing MCU to User System 13...

Page 18: ...tails refer to the Emulator Supplementary Information HS2338EPI61HE To use the emulator internal clock Select the clock in the emulator station as the system clock by using the CLOCK command emulator...

Page 19: ...lator Do not use this cable with any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable 5 While the em...

Page 20: ...Figure 11 P1 Short Connector 16...