( 35 / 76 )
3.3 Selecting Clock Supply
There are two ways to supply a clock to the MCU, using the oscillator circuit of the emulation pod
or using the oscillator circuit on the target system. Table 3.5 lists the factory-settings of each clock
supply.
Table 3.5 Clock supply to the MCU
IMPORTANT
Notes on Changing the Clock Supply:
• The clock supply can be set by the Init dialog box when starting up the emulator
debugger or inputting CLK command on the script window.
• For X
CIN
-X
COUT
, it is necessary to set switches in the emulation pod. For details, refer
to "3.2 Setting Switches and Pullup Resistors" (page 29).
Clock
Description
Display of emulator debugger
Default setting
X
IN
-X
OUT
X
CIN
-X
COUT
Internal oscillator circuit of emulation pod
(OSC-3: 10 MHz)
Target system
Internal oscillator circuit of emulation pod
(OSC-2: 32.768 kHz)
Target system
Internal
External
External
Internal
Yes
-
-
Yes
Summary of Contents for Emulation Pod M306H2T-RPD-E
Page 8: ...6 76 MEMO...
Page 22: ...20 76 MEMO...
Page 52: ...50 76 Figure 4 4 Self check procedure...
Page 76: ...74 76 MEMO...