UM-PM-029
DA9213, DA9214, and DA9215 Performance
Boards
User Manual
Revision 2.0
25-Feb-2022
CFR0012
19 of 37
© 2022 Renesas Electronics
Figure 10: Enabling BUCKA
The same operation can also be done via the I
2
C interface panel by selecting the register address,
the data to send and pressing the
Send
button. A read-back can be performed by clicking the
Read
Figure 11: Middle Right Interface Indicator
After enabling the BUCKA converter it is possible to monitor the output voltage on the PCB via an
external multi-meter connected to the VOUT_A pin, as shown in
. The read-back should
provide a value close to 1.0 V. If the part is not trimmed the value can slightly differ from the target.
It is also possible to directly monitor some relevant signals on the PCB, for example, the inductor
current of each phase.