User Manual
Revision 1.0
27-May-2022
CFR0012
44 of 58
© 2022 Renesas Electronics
UM-WI-058
DA16200 Getting
Started with Azure® IoT
3. Under the
Twin Settings
section, do the following:
a. Set
Device Twin Property
to:
“
properties.desired.fwupdate
”.
b. In the
Device Twin Property Content
field, which defines the version and URL, add a JSON
formatted string.
For example: {
"version"
:"1.0",
"url"
:
"https://da16200otastorage1.blob.core.windows.net/da16200-img-
ontainer/DA16200_FRTOS-GEN01-01-03339ce3d-002291.img"}
Figure 61: Create Configuration
4. Under the
Target Devices
section, do the following:
a. Set
Priority
, for example
“
10
”.
b. Set
Target Condition
to match the
Device ID
in the devices of Azure IoT Hub.
For example,
“deviceid='da16200-device-1'”
.