3.2  Installation tools

Wire cutter

The following tools are required to install the battery

Crimping Modular Plier Crimping

Modular Plier

Note:

Use properly insulated tools to prevent accidental electric shock or short circuits. If insulated tools are not available, cover the 
entire exposed metal surfaces of the available tools, except their tips, with electrical tape.

3.3  Safety Gear

Insulated Gloves

It is recommended to wear the following safety gear when dealing with the battery pack.

Safety goggles

Safety shoes

4.  Installation

4.1  Installation Location:

Make sure that the installation location meets the following conditions:

· 

The area is completely water proof.

· 

The floor is flat and level.

· 

There are no flammable or explosive materials.

· 

The ambient temperature is within the range from 0°C to50°C.

· 

The temperature and humidity is maintained at a constantlevel.

· 

There is minimal dust and dirt in the area.

9

User Manual

LV 48070 Plus     

· 

The distance from heat source is more than 2 meters

· 

The distance from air outlet of inverter is more than 0.5 meters.

· 

Do not cover or wrap the battery case or cabinet.

· 

Do not place at a children or pet touchable area.

· 

The installation area shall avoid directsunlight.

· 

There are no mandatory ventilation requirements for battery, but please avoid installation in confined area. The ambient shall 

  avoid high salinity, humidity or temperature.

Attention

If the ambient temperature exceeds the operating range, the battery pack will stop operating to protect itself. The optimal 
temperature range for the battery pack to operate is  0°C  to   35°C.   Frequent   exposure   to   harsh   temperatures   may   deteriorate   
the performance and life of the battery pack.

4.2  Connection layout of communication cables

Pack 3

Pack 2

Pack 1

To Upper control

Output-

Summary of Contents for LV 48070 Plus

Page 1: ...3 58KWh LiFePO4 Lithium ion Battery Product UserManual 48070 Plus LV...

Page 2: ...pack 12 4 Installation 12 4 1 InstallationLocation 12 4 2 Connectionlayoutofcommunicationcables 13 4 3 Poweron 14 5 Troubleshooting 15 5 1 Uponstart pleasemakesure 15 5 2 Basicsteps 15 5 3 Advancedste...

Page 3: ...tdown 2 It is prohibited to connect the battery with different type ofbattery 3 It is prohibited to put the batteries working with faulty or incompatible inverter 4 It is prohibited to disassemble the...

Page 4: ...ion when running Power self consumption when standby Cooling method IP rating of enclosure Humidity Reference to standards 0 35 15 35 90 integrated integrated 2W 1W 48h 0W 48h Nature Cooling IP20 0 85...

Page 5: ...CAN port For external CAN communication 500KB s between the battery and the power control device 7 RS485 port For internal communication between batteries or between battery and the adapter board of...

Page 6: ...s within the range from 0 C to50 C The temperature and humidity is maintained at a constantlevel There is minimal dust and dirt in the area 9 UserManual LV 48070 Plus The distance from heat source is...

Page 7: ...rating temperature range Recommended operating temperature 0 35 B Current If charging current is over 55A or the discharge current is over 70A battery s self protection function will be activated Solu...

Page 8: ...supply of the battery pack and then put out the re with plenty of water 3 Wet Batteries If a battery is wet or submerged in water people must keep away from it Please contact your dealer or licensed e...

Page 9: ...422 10005 00 SMARTENERGYFORBETTERLIFE...

Reviews: