Remuc Remuc-3 User Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

v 1.1 

Summary of Contents for Remuc-3

Page 1: ...User Manual v 1 1...

Page 2: ...rself with this manual before installation and device use Parts of this manual might differ from the supplied product and or services and is subject to change without separate notice Embelin Oy reserv...

Page 3: ...le application 13 3 2 Connecting application with REMUC 14 3 3 Modifying settings in My REMUC service 15 3 4 Adding user phone number 16 4 REMUC usage 17 4 1 Use button 17 4 2 Mobile application 18 4...

Page 4: ...your mobile phone REMUC uses GSM network for communication and GPS for positioning 1 1 Package contents REMUC 3 controller External GSM antenna lilac connector External GPS antenna blue connector Con...

Page 5: ...in the mobile application User may replace the supplied SIM card with which ever operator card he wants Remuc requires a fixed fee data plan 1 3 IMPORTANT INFORMATION WARNING Familiarize yourself with...

Page 6: ...ne department 2 1 REMUC 3 controller description 2 2 Electrical characteristics Supply voltage 9V 32V Operating temperature 40 80C Typical current consumption 60mA 12V Temperature sensor operating ran...

Page 7: ...button 1 Keep button pressed for at least 10 s Release button REMUC settings reset with the reset button or with the use button 1 Keep reset button pressed for at least 10 seconds Release button 2 Whe...

Page 8: ...Button 7 Input 1 0V 32V min imp 10k transition up 3 V transition down 0 5 V 8 Input 2 0V 32V min imp 10k transition up 3 V transition down 0 5 V 9 Supply voltage 9V 32V 5A fuse required 10 Output 1 0...

Page 9: ...stalled inside car in a dry and protective place Below dashboard on driver side is usually a good place Fix Remuc only on flat surfaces to avoid bending of the casing 3 Install GSM and GPS antennae Th...

Page 10: ...e vicinity of air bags or any other active or passive protective equipment In a place where it might prevent the correct use of the vehicle or block the visibility from the vehicle 4 Install the use b...

Page 11: ...lso supply voltage PIN9 and ground PIN1 Remuc can be configured to control vehicle ventilation In this case connect Output 2 PIN11 to car ventilation control This enables user to control ventilation e...

Page 12: ...ate turns to low Input signal is sampled in 500 ms intervals which means shorter signal changes might go unnoticed PIN NBR FUNCTION DESCRIPTION 7 Tuloliit nt 1 0V 32V min imp 10k transition up 3 V tra...

Page 13: ...o be able to connect REMUC has to have a working SIM card with a fixed fee data plan 3 1 Installing mobile application Remuc mobile application is available on iPhone Android and Windows Phone platfor...

Page 14: ...n with REMUC 1 Launch Remuc mobile application by clicking Remuc icon 2 After clicking Add device enter device name and scan the device QR code using phone camera 3 Confirm new device information by c...

Page 15: ...service http my remuc com Detailed explanation is found in chapter 4 4 My REMUC service My REMUC service requires a working data connection for REMUC The easiest way to login to My REMUC service is v...

Page 16: ...ntrolling phone number as REMUC SMS user SMS user can be added either via My REMUC service data connection required or by making a phone call to REMUC Add SMS user via My REMUC 1 Login to My REMUC ser...

Page 17: ...n controls the default output on and off Default output can be changed in My REMUC service Mobile applications allow controlling REMUC outputs on off both immediately and per schedule Also mobile apps...

Page 18: ...ls in this manual See chapter 3 2 Connecting application with REMUC on how to connect mobile application with REMUC Visible only if REMUC has an Embelin SIM card installed see 1 2 SIM card Can be acti...

Page 19: ...s view A single timer can be deleted by opening the timer item and selecting Remove In iPhone Drag timer item left and tap Remove All active timers are defined per REMUC All active timers are shown on...

Page 20: ...ee chapter 4 5 REMUC input management e g alarm control o IN1 IN2 REMUC input channels see 2 7 Connecting external signal sources to inputs o ING Geofence alarm see 4 6 Geo fence Icon Sound and notifi...

Page 21: ...essed for 10 seconds Modify Change device name check the device ID code allow diagnostics mode for service Remove device Remove the paired device from application Add control Depending on the installa...

Page 22: ...e widget Android application comes with a widget which can be added to phone home view Widget allows quick REMUC control and status monitoring without launching the app itself Widget can t be added if...

Page 23: ...there My Remuc web address is http my remuc com 4 4 1 Logging in There are two ways to log in to My Remuc With a temporary ID number Press My Remuc login button on mobile application and follow instru...

Page 24: ...e identifier code QR code Login ID defined in My REMUC Settings tab Control tab Output control scheduling geofence activation Input states Alarm acknowledgement Map tab Latest REMUC location in map Lo...

Page 25: ...and input control buttons defined in Settings tab Control tab allows to Control and schedule REMUC outputs Monitor REMUC input states Acknowledge possible alerts On top of the view is current supply v...

Page 26: ...automatic events for REMUC Some examples Call a predefined phone number Send an SMS to a predefined phone number Control another REMUC output on off Event area is defined as a circle with user select...

Page 27: ...ommand type Control output Another REMUC SMS Call Receiver If Type Another REMUC target device id QR code Type SMS target phone number Type Soitto target phone number Command If Type Control output co...

Page 28: ...n enter the device ID of the device to control When device ID is verified you can enter the password Once password is verified a command list is shown If device id or password is wrong command selecti...

Page 29: ...reactivated with a separate fee Otherwise the card needs to be replaced You can get a new Embelin SIM card from www remuc com web store 4 4 6 Driver s log Driver s log can be activated in Services tab...

Page 30: ...EMUC 3 User Manual 4 4 7 Settings tab Settings tab allows an easy REMUC configuration manipulation By default only reduced set of settings are visible Enable Advanced settings to make all settings vis...

Page 31: ...l Diagnostics mode gives service access to device history location output and input states device status etc from at least 7 days ago Outputs Output 1 Settings for output 1 Output 2 Settings for outpu...

Page 32: ...alerts SMS phone calls mobile app notifications Alarm control OUTA If either input or geo fence is configured can alarm monitoring be controlled with Alarm control button When Alarm control is active...

Page 33: ...nput type as Alarm Add a new control to mobile app for input OUTA Switching this control on you can disable input monitoring Add a new control for input 1 or 2 Set type as Indicator This will indicate...

Page 34: ...king the input state icon in mobile app must be configured beforehand Name Description Off Acknowledgement not needed Input status changes according to input signal On Acknowledgement needed Input sta...

Page 35: ...se SMS alerts Mobile app notifications use mobile phones platform notifications which might have some latency 4 6 Geo fence Geo fence allows locking the device location so that when target is moved it...

Page 36: ...n this is how it is activated 1 Define a desired geo fence size in kilometers 2 Add your phone number in user management to get alerts as SMS 3 Add two new control buttons in mobile app a OUTA switch...

Page 37: ...ppens automatically based on given parameters This feature is not fit for car heater control but works better for example with cabin heater 4 7 1 Heating with thermostat control Aims to keep the tempe...

Page 38: ...d SMS requires that user phone number is added to the list of approved users see chapter 3 4 Adding user phone number Output control OUT Switches output state Return message contains all output and in...

Page 39: ...LUE DESCRIPTION PORT 1 2 H V A 1 2 OUT1 OUT2 H W BUS Webasto heating V W BUS Webasto ventilation A Alarm control STATE ON OFF RUNNING_TIME 0 65534 Running time in seconds If not given output is on for...

Page 40: ...Eric B Weddington Joerg Wunsch Dmitry Xmelkov Atmel Corporation egnite Software GmbH The Regents of the University of California All rights reserved Redistribution and use in source and binary forms...

Page 41: ...NY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE AES256 Copyright c 2007 2009 Ilya O Levin http www literatecode com Other contributors Hal Finney Permission to...

Page 42: ...CE certification This device fulfils the requirements set by CE certificate EN 50498 2010 Embelin Oy declares that Remuc conforms directive 1999 5 EC relevant standards and regulations Full Declaratio...

Reviews: