- 3 -
6. CHANGING SERVO SETTINGS.
Default servo direction, servo throws and servo centering of channels associated with Pin # 1, Pin # 2 & Pin # 3
can be changed at any time. One change per RX switch ON. Make a single change and then start again.
These processes are in
THREE PHASES
. RX can be powered by any set of pins.
PHASE # 1
– Select the output to change.
To change Pin 1 (Ch # 1) To
change Pin 2 (Ch # 4)
To change Pin 3 (Ch #3)
Put the small bind plug on
pins 4 & 5 (Throttle)
Put the small bind plug on
pins 5 & 6 (Aux 4)
Put the small bind plug on
pins 6 & 7 (Direction)
Procedure.
1. Switch RX ON. RX LED will toggle every ½ second. Remove Bind plug.
2. Switch TX ON. RX LED will flash once every 2s until it locks on to the TX signal and then stay OFF. A servo
on the chosen pin can then be controlled with the TX.
LEAVE TX SWITCHED ON FOR PHASE # 2.
PHASE # 2
. Make changes to selected output. For example, Changing servo default rotation direction.
Changes are made by connecting the signal pin to either Positive (+) or Negative (-).
Only the output being changed works while making changes to it.
TO REVERSE
TO NORMAL
Use the Large bind plug to connect
Pin # 4 to Negative (-).
Use the Small bind plug to connect
Pin # 4 to Positive (+).
PHASE # 3
. Completing changes to channel selected.
(i) Remove the plug and the changes made will be saved.(No indication from LED). Then:
(ii) Switch the RX OFF and ON to use all outputs normally. OR:
(iii) Proceed to changing another channel.