REMKO TX 9000 Manual Download Page 4

Safety Instructions 

 
REMKO electric heaters will provide you with high utility 
and long life thanks to our extensive material, function 
and quality controls. Dangers may arise nevertheless if 
the unit is used by persons not familiar with its operation 
or if the unit is not used for its intended purpose. 

Please pay attention to the following points: 

The persons charged with the operation of the units 
have to check these before starting work as to visible 
defects of the operation and safety devices, as well as 
to make sure that no protective devices are missing. 

In the case of faults the supervisor is to be informed.

 

In the case of faults which endanger the safe opera-
tion of the units, the units are to be stopped! 

During the operation of the units the applicable local 
regulations are to be observed and the relevant 
safety measures to be taken. 

Make sure that the prescribed safety distances from 
combustible objects are observed! 

A free air suction and air discharge must be ensured 

The blow off opening of the unit may not be narrowed 
or equipped with hoses or conduits. 

Never place foreign objects into the unit. 

Do not cover the units during operation. 

The units may not be operated near bath tubs, show-
ers, swimming pools, etc. 

The units may not be operated directly beneath a wall 
socket. 

The units may not be exposed to direct water jets. 

Make sure that no water penetrates inside the units. 

The units may not be operated in rooms which are 
endangered by explosions. 

Protect all electric cables outside the units from 
damage (e.g. caused by animals). 

Starting

 

 
A well trained person is to be charged with the operation 
and control of the units. 

1.   Check the main voltage is in accordance with the 

unit voltage. 

     

400V / 3~, PE / 50 Hz. 

Description of Device

 

 
The units are operating with electric energy and are suit-
able for a fully automatic, all-purpose and simple appli-
cation. 

The units are equipped with capsuled electrical heating 
elements, room thermostat, noiseless maintenance-free 
axial fans,  safety and after-cooling thermostat, 3-stage 
operating switch. 

The units are in accordance with the basic safety and 
health requirements of the relevant EC – regulation. 

The units are handled simply and are safe in operation. 

3.   Connect the CEE-unit plug with an extension cable 

according to the regulations  to an adequate CEE-
mains socket. 

2.   Put operating switch into        

position "0". 

0

3

G

 

The electric connection of the units is to be carried 
out via a special supply point with fault current 
safety switch. 

Application 

Drying of new buildings, spot heating of working places 
outside or in fire-proof halls and production places. 

Permanent or temporary heating of rooms. 

Defrosting of machines vehicles and fire-proof storing 
goods with keeping the prescribed distance of safety. 

Working of device

 

The units are equipped with a 4-stage operating switch. 

In the first stage only the supply air fan is operated and 
the units can be used for air circulation. 

In the 2nd  – 3th. stage the heating elements are acti-
vated and hot air is discharged. 

The units are operated with a room thermostat to en-
sure a constant room temperature. When the pre-
selected temperature has been reached, the thermostat 
stops the heating operation to restart it when the tem-
perature has fallen below the set value. 

When the units have been switched off by the operating 
switch or the room thermostat, the supply air fan contin-
ues running for a certain time to cool down the heat ex-
changer, and then it stops automatically. 

G

 

Never interrupt (except in emergency situations) 
the connection to the mains before the end of the 
whole after-cooling phase.

 

G

 

Connecting cable extensions may be laid exclu-
sively by authorised electricians based on the unit 
capacity, cable length and taking the local terms of 
use into account. 