FUNCTIONAL OVERVIEW
REMKO RVS 100H/150H 60HZ

ABRIDGMENT OF THE MANUAL

  Icon Condenser fan

The icon lights up, if the con-

denser fan is activated.

  Icon Defrosting status

The icon (lights up) displays 

that the defrost cycle in the 

finned condenser is active. 

When blinking the control-

ler is calculating the necessary 

defrosting time.

  Icon Frost protection heating

The LED provides information 

about the operating status for 

the antifreeze protection heat-

ing element.

  Icon "Alarm"

The LED shows that there is an 

alarm.

  Icon Compressor 1

The illuminated LED indicates 

that compressor 1 is in opera-

tion. The LED blinks if the com-

pressor is in safety mode.

  Icon Compressor 2

See description point  .

  Icon Compressor 3

See description point  .

  Icon Compressor 4

See description point  .

  Value display

The value display shows current 

values.

Operating the controller µC

2

SE

The controller has 3 modes:

1. Summer mode (cooling mode)

In cooling mode, the warmer me-

dium temperature is cooled 

down

 

to the preset cooling temperature.

2. Transition mode (heating mode)

In heating mode, the 

colder

 me-

dium temperature is heated 

up

 to 

the preset warmer value.

3. Standby mode (Stand-by)

In the Stand-By mode, safety 

equipment is active but no operat-

ing mode is set. 

  Key " "

Using this key, the current 

menu can be 

resetted

.

  Key " "

This key is used for selecting or 

e.g. to open/close the set point 

or parameter.

  Key " "

Prolonged pressing (5 sec.) 

allows to switch between the 

operating modes “Cooling“and 

“Stand by“. Short pressing, 

displays the current values of 

the temperature probes B1 to 

B3 and the pressure trance-

ducer B4. A value can also be 

increased.

  Key " "

Prolonged pressing (5 sec.) 

allows to switch between the 

operating modes „Heating“and 

„Stand by“. Short pressing 

displays the current values of 

the temperature probes B1 to 

B3 and the pressure trance-

ducer B4. A value can also be 

reduced.

  Key "  and  " pressed to-

gether simultaneously 

Pressing the two keys together 

long (5 sec.), the parameter 

level is opened after password 

is programmed.

  Key "  and  " pressed to-

gether simultaneously 

Pressing long (5 sec.) and to-

gether allows the acknowledge-

ment of an alarm or operating 

hours.

  Key "  and  " pressed to-

gether simultaneously in heat-

ing mode 

Longer pressing together start a 

manual defrost cycle in heating 

mode.

  Icon cooling mode

The icon displays the selected 

cooling mode.

  Icon heating mode

The icon displays the selected 

heating mode.

  Icon "Fan"

The icon lights up, if the con-
denser fan is activated.

  Icon "Pump"

The icon lights up, if the circu-

lating pump is activated.

+

+

+

Controller control panel µC

2

SE

During the initialization of 
the controller (after starting 
the unit and displaying the 
software version, e.g. “H 99”) 
do not push the key “Prg” 
to avoid reprogramming the 
controller!

 

!

   CAUTION

Summary of Contents for RVS 100H

Page 1: ...tand By mode safety equipment is active but no operat ing mode is set Key Using this key the current menu can be resetted Key This key is used for selecting or e g to open close the set point or parameter Key Prolonged pressing 5 sec allows to switch between the operating modes Cooling and Stand by Short pressing displays the current values of the temperature probes B1 to B3 and the pressure tranc...

Page 2: ...B3 16 Calibration B4 21 Digital filter 22 Input limit 23 Unit of measurement C F A01 Set point frost protection A02 Hysteresis frost protection A03 Time delay frost protection A04 Set point medium heating A05 Hysteresis medium heating A06 Probe medium heating A07 min antifreeze protection setting C01 min working time compressor C02 min down time compressor C03 Time delay On On compressor C04 Time ...

Page 3: ...tage controller Tr Supply voltage too low Check the voltage of the transformer both sides EP1 EEPROM driver defective Internal controller error Replace the controller EPb EEPROM alarm at start Config Internal controller error Replace the controller EPr EEPROM alarm during operation Config Internal controller error Replace the controller FL Flow switch has responded ID1 Differential switch Flow swi...

Page 4: ... FR Motor overload protection HP High pressure switch LP Low pressure switch M1 Compressor M2 Circulation pump M3 4 Condenser fan 1 2 RC1 Compressor crank case heater RF1 Defrost heater TA1 Transformer 230 24V TR1 Pressure transducer TS Temperature controller TX1 2Thermal contact fan 1 2 RVS 100H RVS 150H Probe inlet High pressure switch Probe outlet Low pressure switch Four way valve Enable conta...