Unit Shut Down 

 
To shut down the unit, always switch it off with the On / 
Off  button  on  the  control  panel.  Only  now  can  you  un-
plug it on the power supply. 

Never shut the running unit off by pulling the power plug. 
 

Storage 

If the unit is to be taken out of operation for a longer pe-
riod  of  time,  for  example,  over  the  winter,  proceed  as 
follows: 

1.  Empty the internal water tank via the water drainage 

tube on the back of the indoor unit. 

2.  To  do  this,  remove  the  tube  from  its  holder  and  re-

move the sealing cap. 

3.  Collect the water that drains out. 

4.  Reinsert the sealing cap and place the tube securely 

in its holder. 

5.  Let the unit run for approximately 3 hours in circulation 

mode.  
This removes any remaining moisture from the unit. 

6.  Switch the unit off with the On / Off switch. 

7.  Unplug the power cable and wind it up.   

It can be attached to the back of the indoor unit. 

Safety screw M4 

Mounting on an outside wall with straps 

Another way to attach the outdoor unit to a wall or to a 
parapet in the outer area is to use straps. 

1.  Hook the  wall  holders onto the outdoor unit  and se-

cure them with the M4 safety screws. 

Here,  the  wall  holders  maintain  the  proper  distance 
to the wall. 

2.  Hook  one  end  of  the  strap  into  the  fastening  loops 

on the outer part with the snap hook. 

3.  Hang the other end of the strap into the loop screws 

attached to the wall or parapet (Fig. 10). 

Make sure the fasteners are securely attached. 

Mounting height 

The outdoor units (lower edge) may only be mounted a 
maximum of 1.8 m above the setup height of the indoor 
unit (Fig. 11). 

The  condensation  pump  is  only  guaranteed  to  pump 
condensation that builds up in the indoor unit to the out-
door unit up to this height. 

If the outdoor unit is mounted below the setup height of 
the  indoor  unit,  a  distance  of  1.5  m  may  not  be  ex-
ceeded. 

353

 m

Fig. 10 

Loop screw 

Safety screw M4 

Snap hook

 

Fastening loop 

Fig. 11 

20 cm 

m

a

x

1

,8

 m

 

 

Depending on the weather, water may drain out of 
the  water  outlet  on  the  back  of  the  outdoor  unit. 
This is a normal occurrence. 
Select  the  location  for  mounting  the  outdoor  unit 
in  such  a  way  that  the  outcoming  water  does  not 
cause any damage.
 

Fig. 9 

Summary of Contents for RKL 460

Page 1: ...Operation Technology Spare Parts REMKO powerful like a bear REMKO RKL 460 RKL 480 RKL 480 S Line Portable Air Conditioner Edition GB T01...

Page 2: ......

Page 3: ...al Data 12 Wiring Diagram 13 Exploded View 14 Spare Part List 15 Service and Guarantee 15 Environment and Recycling 15 Portable Air Conditioner REMKO RKL 460 REMKO RKL 480 S Line Make sure to read the...

Page 4: ...off by pressing the ON OFF but ton Do not switch the unit off by unplugging the power cable When unplugging the unit always pull the power plug Never pull the cable Do not set up or operate the unit...

Page 5: ...ndoor unit or via the infrared remote control that comes with it The unit is particularly suited for flexible use The de tachable connecting line lets it be installed as a station ary unit Outdoor uni...

Page 6: ...t temperature can be set as de scribed above 2 Unit switches off automatically When the device is on using the SET button the user can enter the number of hours after which the device is to be switche...

Page 7: ...does not overflow This may cause water damage 10 Operating mode and fan setting display This display provides information about the operat ing mode and the fan setting which have been se lected 11 DRA...

Page 8: ...to the outside air To perform this function the outdoor unit can either be placed on the floor or hung on an outside wall Floor installation To set up the outdoor unit on a terrace or balcony it is no...

Page 9: ...to a wall or to a parapet in the outer area is to use straps 1 Hook the wall holders onto the outdoor unit and se cure them with the M4 safety screws Here the wall holders maintain the proper distance...

Page 10: ...er pressure on the upper coupling with the second wrench SW 21 Fig 15 Never turn the inflexible upper part 12 Keep turning until the connection is detached Should refrigerant leak out with a slight hi...

Page 11: ...lly in warm water 4 Then let the filter air dry 5 Reinsert the filter into the unit In case of extreme dirt the dust filter is to be replace Never use the unit without installed dust filter Without a...

Page 12: ...gh Lower temperature Windows and doors open Thermal load increased Close windows and doors Reduce thermal load Condensation water leaks out of the unit The unit is not standing upright Place upright a...

Page 13: ...FM1 Fan motor indoor unit FM2 Fan motor outdoor unit WM Water pump CM Compressor motor OLP Overload protection compressor CX1 Capacitor fan motor indoor unit CX2 Capacitor fan motor outdoor unit CX3...

Page 14: ...oor unit 35 Indoor unit 1 42 11 32 12 10 13 2 13 14 37 34 27 26 25 17 19 18 36 22 23 20 21 39 38 24 7 9 8 35 33 31 28 30 6 3 4 41 40 16 5 15 29 We reserve the right to make modifications in dimensions...

Page 15: ...122 8 Dust filter 1106067 Dust filter RKL 480 S Line 1106123 9 Cover connecting line 1106068 Cover connecting line RKL 480 S Line 1106124 10 Cover bottom 1106069 11 Base plate cpl 1106070 12 Transport...

Page 16: ...REMKO GmbH Co KG Air Conditioning and Heating Technology D 32791 Lage Im Seelenkamp 12 D 32777 Lage P O Box 1827 Phone 49 52 32 606 0 Fax 49 52 32 606 260 E mail export remko de Internet www remko de...

Reviews: