Edition GB - T08

REMKO PWW

Warm water heaters

Operation · Technology · Spare Parts

Summary of Contents for PWW 100 Series

Page 1: ...Edition GB T08 REMKO PWW Warm water heaters Operation Technology Spare Parts...

Page 2: ......

Page 3: ...6 Exploded drawing 20 Spare parts list 20 Intended use 21 Customer service and warranty 21 Environmental protection and recycling 21 Ratings tables Characteristics 22 Calculation examples 30 Planning...

Page 4: ...tion grilles must not be removed or rendered inoperational The units must only be operated within the specified capacity limits and with the approved operating media Observe rating plate The air intak...

Page 5: ...nce Units with fresh air inlet must be fitted with anti frost protection Heat exchanger copper aluminium The fin heat exchangers consist of copper pipes with pressed on aluminium fins The fin assembly...

Page 6: ...to a load bearing outside wall 2 The air intake channel and air inlet piece must be fastened to the outside wall locally 3 Circulation fresh air operation via the roof The vertical part of this syste...

Page 7: ...With the appropriate control units accessory speed selection takes place via Y D switching Motor protection is provided via built in thermal contacts that drop out at a fan motor winding temperature...

Page 8: ...on thread sizes Water inlet Water outlet Air outlet Air inlet NOTE When tightening the screwed connections of the heating medium connection a suitable tool must be used to prevent the connecting pipes...

Page 9: ...ction Where there is s risk of frost the entire system must be drained if no suitable antifreeze agent has been added Note The heat exchanger can only be drained completely using compressed air 9 It m...

Page 10: ...1 Disconnect the electrical con nection of the motor 2 Remove the protection grille with fan from the housing 3 Remove the protection grille from the fan motor 4 Carefully refit the new fan in revers...

Page 11: ...ofitting is easily possible Air outlet hood HG 4 This air outlet hood serves uniform air distribution in four directions at low mounting heights The air outlet hood is not suitable for mounting hoods...

Page 12: ...00 1295 690 55 60 Filter box FK with pocket filter insert removable from the side filter class G3 depth 100 mm PWW a in mm b in mm c in mm 30 560 440 400 50 640 515 400 80 800 630 400 100 880 740 400...

Page 13: ...20 100 840 410 1000 500 20 PWW a in mm b in mm c in mm d in mm 30 520 240 400 20 50 600 310 450 20 80 760 360 650 20 100 840 410 800 20 Flexible pipe SG Flexible conn vibration isolation betw unit and...

Page 14: ...e final pressure difference is reached the filters must be replaced with filters with the same quality class Accessory installation Anti frost thermostat FS The anti frost thermostat is a precise wate...

Page 15: ...ction IP 54 Operating time about 150 seconds Maximum ambient temperature 50 C Typ KSH N L1 230V 1 1 2 3 Aderbezeichnung Wiring diagram Stellungsgeber 0 10V Aderbezeichnung 1 2 3 5 N L1 y N L1 230V 1 1...

Page 16: ...upply and protective conductor terminals main con tactor control switch with the functions Off Setting 1 Setting 2 control fuse indicator light extinguishes on fan faults and or interruption of power...

Page 17: ...ctions based on the wiring diagrams in compliance with the applicable regulations taking into account local regulations Three phase 400V two speed fan maximum switching capacity 2 5 kW surface mountin...

Page 18: ...es place via a large sized membrane keyboard In the automatic mode the fan speeds are controlled according to the freely programmable tempera ture difference Day night temperature control in cluding w...

Page 19: ...ion Weight Control unit V A IP kg 3 EG 400 3 0 54 11 1 5 EG 400 5 2 54 15 6 EG TK TK W2 U2 V2 W1 V1 U1 J N L1 L2 L3 U1 V1 W1 TK TK RT RT N L1 L2 L3 PE J FS FS 12 11 14 N L L Raum thermostat Frostschut...

Page 20: ...WW 50 EDP No PWW 80 EDP No PWW 100 EDP No 1 Heat exchanger Bg 2 1105211 1105215 1105219 1105223 1a Heat exchanger Bg 3 1105212 1105216 1105220 1105224 1b Heat exchanger Bg 4 1105213 1105217 1105221 11...

Page 21: ...should be contacted Intended use Disposal of packaging Think of the environment when disposing of the packaging material Our appliances are carefully pa cked for transport and delivered in sturdy card...

Page 22: ...0 21 1 31 17 4 31 19 0 35 15 8 36 16 7 36 13 6 37 13 8 37 11 7 38 11 5 38 9 3 38 29 9 28 27 5 35 28 2 31 25 5 36 26 4 33 23 5 38 24 5 36 21 4 39 22 9 41 19 4 43 21 1 43 17 4 44 19 0 45 15 8 46 16 7 46...

Page 23: ...Accessories mounted on pressure side Component Type D Mixed air box MLK 5 Filter box filter clean FK 2 moderate filter clogging FK 7 Warmth channel interim piece per m KA 1 Fresh air inlet grille AG 4...

Page 24: ...7 34 9 30 28 8 29 31 4 34 25 7 33 27 6 36 21 9 34 22 8 36 19 0 36 18 2 37 15 8 37 52 9 31 45 1 30 49 7 33 42 1 32 46 1 35 38 8 34 42 6 37 35 3 35 38 8 41 32 2 40 34 9 43 28 8 41 31 4 44 25 7 43 27 6 4...

Page 25: ...x filter clean FK 2 moderate filter clogging FK 7 Warmth channel interim piece per m KA 1 Fresh air inlet grille AG 5 Circulation suction adapter UA 2 Fresh air inlet hood ALH 4 Component Type D Air o...

Page 26: ...34 49 0 36 52 3 38 44 2 41 46 6 39 39 5 42 40 9 41 33 9 42 35 3 42 28 4 43 85 2 35 72 5 39 79 7 36 67 8 40 74 2 38 63 1 42 68 7 40 58 4 43 63 2 45 53 7 48 57 7 46 49 0 50 52 3 48 44 2 51 46 6 49 39 5...

Page 27: ...ox filter clean FK 3 moderate filter clogging FK 7 Warmth channel interim piece per m KA 1 Fresh air inlet grille AG 4 Circulation suction adapter UA 2 Fresh air inlet hood ALH 4 Component Type D Air...

Page 28: ...1 33 74 1 34 65 8 37 65 5 36 58 9 39 56 9 37 50 9 40 48 1 39 43 6 41 126 0 30 110 3 34 117 5 32 102 8 36 108 7 34 95 3 37 100 0 36 88 1 39 91 3 41 80 5 44 82 8 42 73 1 45 74 1 44 65 8 47 65 5 46 58 9...

Page 29: ...x filter clean FK 3 moderate filter clogging FK 8 Warmth channel interim piece per m KA 1 Fresh air inlet grille AG 4 Circulation suction adapter UA 2 Fresh air inlet hood ALH 4 Component Type D Air o...

Page 30: ...d Filter box FK 7 Air outlet nozzle AD 9 Total difference 16 Solution from the diagram VL 3400 2400 m3 h The heat outputs shown in the ratingtables are subject to variation as a result of Reduced air...

Page 31: ...ating For the calculation example this results in Higher speed Air volume ratio Heat output correction factor fQ 0 75 Effective heat output QL 50 1 x 0 75 37 6 kW Lower speed Air volume ratio Heat out...

Page 32: ...capacity Q of the REMKO heater takes into account the following components 1 Heat requirement QH of room to be heated Calculation according to DIN 4701 and 4108 2 Heat requirement QAL to heat fresh a...

Page 33: ...nlet temperature at air heater tL2 C Air outlet temperature at air heater t C Air inlet outlet temperature difference at air heater t tL2 tL1 tW C Heating medium inlet outlet temperature difference at...

Page 34: ...0 2 50 3 50 4 80 2 80 3 80 4 100 2 100 3 100 4 V R R 1 R 1 R R 1 R 1 R 1 R 1 R 1 R 1 R 1 R 1 R R R 1 R 1 R R 1 R 1 R 1 R 1 R 1 R 1 R 1 R 1 We reserve the right to make changes to dimensions and design...

Page 35: ...ater or pumped hot water up to maximum 130 C Operat press max bar 16 16 16 16 16 16 Weight kg 24 26 27 31 34 36 Series PWW 80 2 PWW 80 3 PWW 80 4 PWW 100 2 PWW 100 3 PWW 100 4 Elec connection V 400 3...