Exploded view MXD 200 to MXD 520

1

We reserve the right to modify the dimensions and structural 

design as part of the ongoing technical-development process.

Spare parts list

No.

Designation 

MXD 200

MXD 260

MXD 350

MXD 520

1

Air inlet guard

1111030

1111030

1111030

1111030

2

Air filter

1111031

1111031

1111031

1111031

3

Cover

1111032

1111032

1111032

1111032

4

Fin motor

1111033

1111033

1111033

1111033

5

Condensation tray 

1111034

1111034

1111034

1111034

6

Outlet fins, set of 4

1111035

1111035

1111035

1111035

7

Vaporiser

1111036

1111036

1111049

1111050

8

Condensation pump, cpl. 

1111037

1111037

1111037

1111037

9

Fan wheel

1111038

1111038

1111038

1111038

10

Vaporiser fan motor

1111039

1111039

1111039

1111039

11

Control board

1111040

1111040

1111040

1111040

12

Transformer

1111041

1111041

1111041

1111041

13

Condenser, vaporiser fan

1111042

1111042

1111048

1111051

14

IR remote control

1111052

1111052

1111052

1111052

Spare parts (not illustrated)

Condensation float switch

1111044

1111044

1111044

1111044

Display board

1111045

1111045

1111045

1111045

Air circulation sensor

1111046

1111046

1111046

1111046

Vaporiser sensor

1111047

1111047

1111047

1111047

When ordering spare parts, please state the computerised part no., device number and device type (see identification plate)!

2

6

3

5

7

8

9

10

11

12

13

14

4

25

Summary of Contents for MXD 200

Page 1: ...Issue GB W06 REMKO MXD MXD 200 MXD 260 MXD 350 MXD 520 Ceiling cassette Operation Technology Spare parts...

Page 2: ......

Page 3: ...tal protection and recycling 4 Warranty 4 Intended use 5 Transport and packaging 5 Equipment description 5 Combinations 6 7 Operation 8 14 shut down 15 Care and maintenance 15 16 Troubleshooting and c...

Page 4: ...ing some parts of the equipment can result in burns or other injury Installation repair and mainte nance work may be carried out only by authorised specialists Visual inspections and cleaning can be p...

Page 5: ...con nect the indoor unit to the outdoor unit Outdoor component System layout Condenser fan Outdoor area Injection line Suction line Control cable Condensation line Indoor area Condensation line Indoor...

Page 6: ...Combination 1 Combination 2 Combination 3 Two indoor units Combination 4 Combination 5 Combination 6 Combination 8 Combination 9 Three indoor units Combination 13 Combination 14 Combination 15 Combin...

Page 7: ...0 One indoor unit Combination 1 Combination 2 Combination 3 Combination 4 Two indoor units Combination 5 Combination 6 Combination 7 Combination 8 Combination 9 Combination 10 Combination 11 Combinati...

Page 8: ...ly operated Faults are indicated in code see chapter Troubleshooting and Customer service CAUTION Immediately replace flat batter ies with a new set otherwise there is a risk of leakage It is recommen...

Page 9: ...e left LOCK button prevents subsequent operation the right RESET button resets the display Buttons on the remote control ON OFF button Press this button to start the unit MODE button Use this button t...

Page 10: ...ating cooling and air circulation modes The nominal temperature can be preselected and is then applied in automatic mode The fan speed is auto matically adapted to the given circumstances AUTOMATIC MO...

Page 11: ...the vaporiser is lower The excess moisture in the air is condensed by the vaporiser the room is dehumidified The fan speed should be set to automatic in order to achieve a maximum level of dehumidifi...

Page 12: ...re and the actual room temperature If there is a large difference a higher cooling output is produced If there is a small difference a lower cooling output is produced This serves to maintain the air...

Page 13: ...ction of the air discharge fins can be adjusted with this button The air distribution in the room is improved by the swing function In order to adjust the aim of the air discharge fins to a particular...

Page 14: ...activation delay Activation delay TIMER OFF button switch off delay CANCEL delete timer program Switch off delay Time stored TIMER ON TIMER ADJUST TIMER ADJUST TIMER ADJUST OK TIMER OFF CANCEL CLOCK 2...

Page 15: ...and other deposits Clean the unit using a damp cloth Do not use any caustic abrasive or solvent based clean ing products Do not use a jet of water Clean the fins on the unit prior to long shutdown per...

Page 16: ...g agents To do so turn the dirty side downward Fig 3 6 When using water allow the filter dry out properly in air before replacing it in the unit 7 Carefully insert the filter Make sure it is seated co...

Page 17: ...terference Signal is not transmitted when interference sources are operational Button in remote control jammed two buttons pressed at same time Does the Send symbol appear on the display Release the b...

Page 18: ...n leads flashes flashes E0 EEPROM error Check EEPROM flashes On Inverter module shutdown flashes Condensation pump float switch faulty tripped Contact specialist dealer flashes On E4 Outdoor temp sens...

Page 19: ...re and never kink or compress the refrigerant pipes Only use the union nuts for the refrigerant pipes included in the delivery and remove them shortly before connecting the refrigerant pipes Establish...

Page 20: ...it a trap to prevent any unpleasant odours When operating the unit at outdoor temperatures below 4 C ensure the condensation pipe is laid to protect it against frost If necessary fit supplementary pip...

Page 21: ...or unit contains a data cable which makes communication between the indoor unit and the outdoor unit possible This is used for controlling cooling and heat ing output and for forwarding fault indicati...

Page 22: ...Schwarz U W V U V W P N IPM 10PIN W V U L202 IPM EEW T5 CN4 CN12 CN5 CN5 CN16 CN11 CN1 CN2 Trans Trans CN20 CN27 CN28 CN9 Hochdruckschalter Niedrigdruckschalter R2503 P 3 P 4 P 5 P 6 P 2 3 CN3 R1815B...

Page 23: ...parts Familiarise the operator with the system 3 Measure and record all the required values in the commis sioning report and check the safety functions 4 Check the control system for the unit using th...

Page 24: ...REMKO MXD 24 Notes...

Page 25: ...Condensation pump cpl 1111037 1111037 1111037 1111037 9 Fan wheel 1111038 1111038 1111038 1111038 10 Vaporiser fan motor 1111039 1111039 1111039 1111039 11 Control board 1111040 1111040 1111040 11110...

Page 26: ...ing range room volume approx m 60 80 110 160 Room temperature adjustment range C 17 to 30 Operating range C 17 to 32 Refrigerant R 410A 4 Operating pressure max per cooling circuit kPa 4200 4200 Air f...

Page 27: ...Seelenkamp 12 D 32791 Lage Equipment machinery Implementation Multi inverter ceiling cassette Series Model REMKO MXD 200 MXD 260 MXD 350 MXD 520 Series Class Number 770 771 772 778 Applicable regulat...

Page 28: ...our customers on air conditioning and heating technology Customer Service Our equipment operates pre cisely and reliably However in the event of a fault REMKO customer service is quickly at the scene...

Reviews: