Data specific to indoor unit
SKW 261 DC IT
SKW 351 DC IT
SKW 521 DC IT
Application area (room volume), approx.
m
3
80
110
160
Adjustment range, room temperature
°C
+16 to +30
Air flow volume per stage
m
3
/h
360/460/520
360/500/600
540/680/840
Sound pressure level per stage
5)
dB (A)
26/30/40
26/34/40
30/37/44
Sound pressure level, Silent
dB (A)
21
22
25
Sound power level max.
5)
dB(A)
53
55
Enclosure class
IP
X0
Condensate drainage connection
mm
18
Dimensions: H/W/D
mm
285/805/194
302/957/213
Weight
kg
7.5
10.0
EDP no.
1648263
1648353
1648523
5)
At distance of 1 m in the open air; specified values are maximum values