12

REMKO ETF 320

The units are equipped with four 
foot rollers and an additional 
handle for easy and convenient 
transport. 

   Before each change of location, 

switch off the unit and remove 
the power plug from the mains 
socket

   Empty the condensate 

container completely

 

  If moisture residual remains on 

the evaporator or water remains 
in the condensate container, the 
units must only be transported 
in an upright position

   The transport rollers are only 

suitable for use on level and 
smooth ground

   The devices must be carried 

when transporting on rough 
terrain or uneven surfaces

All moving parts have  
a low-maintenance permanent 
coat of lubricant. The entire 
refrigerant system is designed as 
a maintenance-free, hermetically 
sealed system and may only be 
repaired by a specialist.

  Observe the regular care and 

maintenance intervals

   In accordance with the 

operating conditions, the units 
must, if necessary, be checked 
at least yearly by a specialist 
to ensure that they are in 
a condition that is safe to use

   Only clean the units with a dry 

or damp cloth 

Do not use a water jet!

 

   Never use abrasive or 

solvent-based cleaners 

   Use only suitable cleaners, even 

for heavy contamination

   Check the inlet and outlet grille 

for contamination on a regular 
basis 

Clean or replace if required!

Care and maintenance

NOTE

Regular care and maintenance 
is fundamental to a long 
service life and fault-free 
operation of the unit.

NOTE

Beware of dripping 
condensate. 
After switching off the units, 
the evaporator may continue 
to defrost under the influence 
of the ambient temperature. 

Cleaning the condenser and 
evaporator 

The unit housing must be opened 
to allow the inside of the unit to be 
cleaned and to provide access to 
electrical components. 

   Clean the condenser and 

the evaporator by blowing, 
vacuuming or using a soft brush  

Do not use water jets!

   Clean the interior surfaces

on the units, the condensate 
traps with hose connection, 
the fan and the fan housing 
carefully

   Check all unit components for 

damage and repair if necessary

   Carefully refit all parts that 

were removed in reverse order

NOTE

When cleaning the exchanger, 

particular care must be taken 

because the fine aluminium 

fins bend very easily.

NOTE

Adjustment and maintenance 
work may only be carried out 
by authorised and qualified 
technicians.

Unit transport

Before undertaking any work 
on the units, the power plug 
must be removed from the 
mains socket.

 

!

   CAUTION

The mains cable must never 
be used as a pull cord or fixing 
device.

 

!

   CAUTION

An electrical safety check must 
be carried out in accordance 
with VDE 0701 after any work 
on the units.

 

!

   CAUTION

Summary of Contents for ETF 320

Page 1: ...Edition GB I03 REMKO ETF 320 Mobile dehumidifiers Operation Technology Spare parts...

Page 2: ......

Page 3: ...or on the unit itself Subject to modifications no liability accepted for errors or misprints Air dehumidification 4 Safety notes 6 Unit description 7 Set up 8 Commissioning 9 Shutdown 11 Unit transpo...

Page 4: ...r vapour released from parts of a building or materials is absorbed by the surrounding air As a result the moisture content increases which ultimately gives rise to corrosion mould rot peeling of pain...

Page 5: ...emperature to fall below it Building materials and structures are capable of absorbing considerable volumes of water such as brick 90 190 l m heavy concrete 140 190 l m and limestone 180 270 l m The d...

Page 6: ...t on the output of the unit but is determined to a greater extent by the speed at which the material or building section loses its moisture The units have been subjected to extensive material function...

Page 7: ...xtinguishes again when the empty condensate container is re inserted The units then restart after a switch on delay of around 3 minutes In unattended continuous operation with an external condensate c...

Page 8: ...if the unit is set up approx 1 m above the ground The room being dried or dehumidified must be closed to the surrounding atmosphere Avoid having opened windows and doors etc and avoid frequent entry...

Page 9: ...a waiting time of 3 minutes has elapsed Restart protection NOTE The devices can be switched ON and OFF via an external time accessory if required Before commissioning the unit or if local requirements...

Page 10: ...rly fast and effective and guarantees high dehumidification performance Dehumidification mode is only paused for a short time during the defrost phase The Defrost mode indicator light indicates that t...

Page 11: ...the connection nozzle that is now exposed In unattended permanent operating mode the condensate should preferably be drained into a lower level drain If using an external collection container pan buck...

Page 12: ...utlet grille for contamination on a regular basis Clean or replace if required Care and maintenance NOTE Regular care and maintenance is fundamental to a long service life and fault free operation of...

Page 13: ...ax 40 C soap solution Finally always rinse the filter carefully with clear water and allow to dry 7 Also check the intake grill for contamination and clean if necessary 8 Before refitting grill and fi...

Page 14: ...tutory or locally applicable regulations The unit is loud or condensate runs out Check whether the unit is on a stable and even base Check whether the unit is standing upright and stably Have the cond...

Page 15: ...are environmentally friendly and can be recycled By recycling packaging materials you make a valuable contribution to the reduction of waste and conservation of raw materials Therefore only dispose o...

Page 16: ...it We reserve the right to modify the dimensions and design as part of the ongoing technical development process 1 3 6 5 10 29 27 34 24 19 16 15 40 41 43 17 18 26 28 39 9 25 7 35 36 32 23 30 33 21 31...

Page 17: ...1103673 20 Fan motor 1103661 21 Fan housing 1111133 22 Fan wheel 1103636 23 Protection grid 1103637 24 Condenser fan motor 1103668 25 Distribution block 1111134 26 Mains cable with plug 1103660 27 Boa...

Page 18: ...Fan function checked Air inlet grid with filter cleaned Unit checked for damage Safety devices checked All fastening screws checked Electrical safety check Test run 1 Date Signature 2 Date Signature 3...

Page 19: ...15 2 At 15 C 60 RH l day 8 4 Max airflow volume m3 h 190 Condensate container capacity Litres 5 5 4 5 Refrigerant 1 R 410A Refrigerant quantity g 180 Power supply V 230 1 Frequency Hz 50 Max rated cur...

Page 20: ...dvisers to our customers in air conditioning and heating technology Customer service Our units operate precisely and reliably However in the event of a malfunction REMKO customer service is quickly on...

Reviews: