REMKO ELT 2-1 Operating And Installation Instructions Download Page 4

4

REMKO ELT series

Safety notes

Always observe the respective local building code and fire prevention 
guidelines as well as the guidelines of the accident prevention and 
insurance associations when using the units.

The units have been subjected 
to extensive material, functional 
and quality inspections prior 
to delivery. However, dangers can 
arise from the units if they are 
used improperly or not as intended 
by untrained personnel!  

Please observe the following notes

  The personnel tasked with 

operating the units must check 
the units for visible defects on 
the operating and safety devices 
as well as the presence and 
function of the protective devices 
prior to starting work

Inform 

the supervisor if defects are 
discovered!

  In the event of defects that 

endanger the operational safety 
of the unit, operation must 
be discontinued immediately

  Observe the respective local 

regulations and the relevant 
electrical safety measures when 
using the units

  Maintain safety distances 

to combustible materials

  An unobstructed air inlet and air 

outlet must be guaranteed at all 
times

  The air outlet must not 

be constricted or equipped with 
pipe or hose lines

  Never insert foreign objects into 

the units

  The units must not be covered 

during operation

  Safety devices must not 

be bypassed or disabled

  The units must not be operated 

in the vicinity of bathtubs, 
showers, swimming pools etc.

  The units must not be operated 

directly below a wall socket

  The units must not be exposed 

to direct jets of water 
e.g. 

pressure washers etc.

  Never allow water to enter 

the units

  The units must not be installed 

or operated in potentially 
flammable or explosive 
environments

   The units must not be installed 

or operated in atmospheres 
containing oil, sulphur or salt

  All electrical cables for the 

units must be protected against 
damage, even damage caused 
by animals

  The units must be set up in 

a stable, horizontal position

Unit description

The units are portable electric 
heating units for industrial 
applications.  
The units are operated exclusively 
with electric power and have been 
designed in such a way that they 
can be used fully automatically, 
universally and in a straightforward 
manner.

The units are equipped with 
specially enclosed electric heating 
resistors, low noise and low-
maintenance axial fans, a safety 
and aftercooler thermostat, an 
integrated room thermostat and 
a power cable with protective 
contact plug.

The units conform to 
the fundamental health and safety 
requirements of the appropriate 
EU stipulations.

The units are dependable and offer 
ease of operation.

The units may be used among 
other things for the following:

   Drying newly completed 

buildings

   Spot heating outdoor 

workspaces or fire-proof 
manufacturing facilities and 
halls

   Continuous or temporary room 

heating

   De-icing machines, vehicles and 

non-combustible warehoused 
goods while adhering to 
the relevant safety distances

CAUTION

Safety devices must not be 

bypassed or disabled.

Summary of Contents for ELT 2-1

Page 1: ...d installation instructions This product is suitable only for well insulated rooms or for occasional use Edition EN Q03 Read the instructions prior to performing any task ELT 2 1 REMKO ELT series Elec...

Page 2: ......

Page 3: ...nity of the installation location or on the unit itself Subject to modifications no liability accepted for errors or misprints Safety notes 4 Unit description 4 Commissioning 5 Shutdown 6 Care and mai...

Page 4: ...pools etc The units must not be operated directly below a wall socket The units must not be exposed to direct jets of water e g pressure washers etc Never allow water to enter the units The units must...

Page 5: ...perates in a fully automatic manner subject to the temperature that is set on the thermostat 1 Set the desired room temperature on the thermostat 2 Move the operating switch to the I Heating position...

Page 6: ...afety equipment and protective devices on a regular basis Be careful not to damage the thermostat s probe or capillary tube when removing or mounting the rear panel of the unit The unit fan does not s...

Page 7: ...by appropriately instructed personnel With non observance of the manufacturer s specifications the respective local legal requirements or after arbitrary alterations to the units the manufacturer shal...

Page 8: ...MKO ELT series We reserve the right to modify the dimensions and design as part of the ongoing technical development process 1 2 6 7 19 17 18 8 5 16 15 9 Exploded view of the unit 12 10 11 3 4 20 15 1...

Page 9: ...limiter 1101161 5 Inner casing 1103931 6 Heating resistor 1103909 7 Front panel 1101063 8 Floor panel 1103932 9 Fan blade 1103819 10 Drive clutch 1103912 11 Fan motor 1103820 12 Back wall 1103915 13 P...