![REMKO ELT 10-HT Operation,Technology,Spare Parts Download Page 11](http://html1.mh-extra.com/html/remko/elt-10-ht/elt-10-ht_operation-technology-spare-parts_1438911011.webp)
11
Spare parts list
Technical data
1)
Noise level measurement DIN 45635 - 01 - KL 3
Series
ELT 10-HT
Nominal heat capacity
kW
10.5
Switchable heating capacity
kW
Thermodynamic
Air volume
m
3
/h
400-900
Air outlet temperature
°C
up to 120
Maximum ambient temperature
°C
60
Power supply
V/Hz
400/3~N / 50
Max. rated current
A
15.9
Max. power consumption
kW
11
Electrical protection (provided by the customer)
A (slow)
16
Sound pressure level L
pA
1m
1)
dB (A)
70
Dimensions: Length
mm
750
Width
mm
305
Height
mm
500
Weight
kg
18.0
No.
Designation
EDP
21
Grommet for mains cable
EDP no. on
request
22
Fan with motor and protection
grid
23
Condenser
24
“RED” light (STB fault)
25
“GREEN” light (max. heating capacity)
26
“YELLOW” light (HT mode)
27
Thermostat receptacle assembly
28
6.3 A control fuse
29
Speed controller adjusting knob
30
Operating switch 1-0-2
31
Speed control film
32
Mains cable with plug
33
M012 speed control
34
Terminal block 6er (1.5 mm²)
35
Speed controller
36
Safety thermostat STB
Not
illustrated Thermostat plug
Not
illustrated Strapping plug
Not
illustrated Operating hours counter
No. Designation
EDP
1
Transport handle
EDP no. on
request
2
Reinforcement plate
3
Outer casing ELT 10-HT
3a
Outer casing ELT 10-HT INOX
4
Front panel with outlet nozzle
5
Floor panel
6
Front plate of floor panel
7
Support plate, right
8
Heating insert assembly
9
Back wall
10
Support plate, left
11
Inner casing with outlet cone
12
Cover plate for STB
13
Mounting plate
14
Terminal block 6er (6 mm²)
15
Contactor
16
Aftercooler thermostat
17
Control thermostat with probe
18
Safety clamp for mains cable
19
EMC filter
20
Terminal block 5er (16mm²)
When ordering spare parts, please state the EDP no., unit number and type (see name plate)!