3
Unit description
The fresh water station is a pre-installed valve
group that was checked for leak tightness; it is
used to transfer heat between the buffer tank and
the domestic water circuit. It contains a pre-set
controller and important valves for operating the
system:
n
Ball valves in the primary circuit
n
Piston valves in the secondary circuit
n
Safety valve in the secondary circuit
n
Pre-installed controller
n
Temperature probe on the cold water supply
n
Temperature probe on the heating supply
n
Ultrasonic flow rate meter on the domestic hot
water outlet
n
Primary pump that can be shut off
n
Ball valve for filling/drainage, for bleeding the
heat exchanger and the pump
NOTICE!
A check for pressure and leak tightness after
successful installation must always be per-
formed before commissioning
REMKO GmbH & Co. KG herewith confirms
that the supplied product corresponds to the
UBA (German Environment Agency)
positive list.
A
B
C
E
1
2
3
4
7
6
8
9
10
11
5
D
12
13
14
Fig. 3: Product description
A: Primary side: Return to the buffer tank
B: Secondary side: Hot water circulation, return
C: Secondary side: Cold water inlet
D: Secondary side: Hot water outlet
E: Primary side: Inlet from the buffer tank
1:
Ball valve with gravity brake
2:
Primary pump
3:
Check valve with drain valve
4:
Circulation pump
5:
Piston valve (green) with drain valve
6:
Piston valve (blue) with drain valve
7:
Piston valve (red) with temperature probe
8:
Ultrasonic flow rate meter FlowSonic
9:
Ball valve for filling/drainage and temperature
probe
10: Plate heat exchanger
11: Circulations pipe
12: Temperature probe (primary cycle)
13: Safety valve and temperature probe
14: Ball valve with gravity brake
REMKO fresh water station
10