8
Addressing the EC1
A maximum of three probes can be supplied with
mains voltage via the power supply of the REMKO
I/O module. If further remote controls are still to be
installed, they must be supplied with a separate
230 V mains voltage. Each probe, such as a room/
humidity probe or Smart-Control Touch remote
control must be assigned its own BUS address.
This address must be stored in the Smart Control
Touch at the corresponding parameter level of the
assigned heating/cooling cycle.
Fig. 7: Setting the BUS address
The BUS address for the Easy-Control room ther-
mostat can be found in the expert level as param-
BUS address for room temperature/humidity
probe
Parameter
BUS address
c
"01 - 99"
For addressing the BUS address of the Easy-Con-
trol room thermostat, open the expert level as
. Under point “c” you can assign a BUS
address for your room thermostats. Make sure that
all components to which you assign an address
are assigned different addresses. If a room/
humidity probe and Easy-Control room thermostat
for example are assigned the same address, this
will result in malfunctions.
After the setting is entered, it is not necessary to
save the parameter. The data is accepted automat-
ically.
Expert level
¯
Settings
¯
Select heating cycle
¯
For example: unmixed cycle
Parameters in the selected cycle
Operating mode
Heating cycle mode
Fixed value
Heating curve adjustment
Cooling cycle mode
Fixed value
Cooling curve adjustment
Time program A
Time program B
Time program C
Time program function
Room temperature reduction
Room temperature increase
☛
Room unit (OFF)
☚
for example: Easy-Control EC1
BUS address: Easy-Control EC1
Room temperature influence
Dew point monitoring
Dew point distance
Pump type
Min. pump speed A42 (%)
Max. pump speed A42 (%)
Min. pump speed A42 (rpm)
Max. pump speed A42 (rpm)
Pump during cooling
REMKO remote controls
18