background image

17

Spare Part List

When ordering spare parts please indicate ref.-no. and machine no. (see type plate)!

No. Description

EDP-No.

No. Description

EDP-No.

01

Exhaust connection

1103702

54

Side cover, left

1103772

02

Inspection cover

1103740

55

Retaining ring 

1101622

03

Inspection cover

1103703

56

Wheel cap

1101623

04

Gasket (inspection cover)

1103705

57

Transport handle, front

1102932

05

Combustion chamber cpl.

1103728

58

Wheel

1102155

08

Air slide plate

1103729

59

Fuel tank

1103727

09

Air flow plate

1103730

60

Rubber grommet

1103775

10

Nozzle

1103744

61

Filler cap

1102148

11

Holder (nozzle)

1107132

62

Fuel filter

1103776

12

Mounting plate

1103731

63

Transport handle

1102931

13

Ignition electrode

1107139

64

Gasket ring

1103777

15

Ignition cable

1107137

65

Drain screw

1103778

19

Nut M14

1107134

66

Tank heating

1102256

20

Photo cell cable

1103732

67

Cover (tank heating)

1103779

21

Photo cell

1108209

68

Eectric board cpl.

1103780

23

Recool thermostat,

1107182

69

Ignition transformer

1107143

26

Protecting grille

1103753

70

Terminal strip cpl.

1103781

27

Mounting clip

1103733

71

Mounting

1103782

28

Fan blade

1103754

72

Relay socket

1102534

29

Fan housing

1103734

73

Automatic burner

1102239

30

Air baffle plate, right

1103756

74

Locking screw (PG-plate)

1102533

31

Air baffle plate, left

1103757

75

O-ring seal

1103783

32

Protective socket

1102131

76

Cover with mounting plate

1103784

33

Housing base

1103758

77

Fuse

1103785

34

Mounting clip

1102906

78

Connecting cable with plug

1101320

35

Blow-out cone

1103759

79

Thermostat socket

1101018

36

Bracket STB feeler

1103760

80

Bridge circuit plug

1101019

37

Mounting clip STB feeler

1103761

83

Operating switch I 0

1111677

38

Fuel hose L240

1103835

85

Safety temperature-limiter (STB)

1103711

39

Hose clamp

1103762

86

Auxiliary relay 

1107375

40

Fuel filter (one-way)

1102146

91

Photo cell bracket

1111676

41

Cover (filler neck)

1103763

92

Solenoid valve cpl. (Danfoss)

1103863

42

Protective socket

1103764

93

Connecting nipple 1/8“

1111672

43

Connection cable (solenoid valve) 1102825

94

Oil pressure pipe (flex)

1111673

44

Fuel pump cpl. 

1103765

95

Connecting nipple 

1/4

1111674

45

Solenoid 

1103766

96

Oil hose L300

1103836

47

Pump clutch

1107129

97

Burner head

1103793

50

Capacitor

1103768

98

Protective conductor plug flag

1103837

51

Fan motor cpl.

1103737

Not shown:

52

Cover, front / back

1103770

Thermostat plug

1101020

53

Side cover, right

1103771

Cartridge filter for oil pump

1102088

Summary of Contents for ATK 25

Page 1: ...REMKO ATK 25 Automatic oil heater with built in oil burner tank and exhaust gas connection Operation Technology Spare Parts Edition GB D05...

Page 2: ......

Page 3: ...4 Intended use 14 Electrical Wiring Diagram 14 Trouble Shooting 15 Exploded view 16 Spare Parts List 17 Maintenance log 18 Technical Data 19 Before commissioning use of the equipment these operating i...

Page 4: ...s operation The unit must be set up and operated in such a way that people are not endangered by exhaust fumes and radiated heat and no fires can break out The unit may be set up and operated in rooms...

Page 5: ...t the automatic tank heater is activated for tempe ratures below 10 C When the unit has been switched on or when heat is required auto matic function with room thermo stat the supply air fan starts Th...

Page 6: ...is the case if e g 1 The room contents in m corre spond with at least 30 times the nominal heat output of all units operating in the room and a natural change of air is ensured through windows and doo...

Page 7: ...air supply appropriate to the respective forced air burner capacity see name plate Outdoor mounting Due to the operation of the unit no dangers or unreasonable nuisances may arise The unit operator mu...

Page 8: ...doors or in open rooms the operation of the device is also possible without an exhaust system However we recommend a 1 m exhaust pipe see example 2 with a rain hood placed on top so as to rule out the...

Page 9: ...Make sure that combustion air is supplied Make sure that the air can be sucked in and be exhausted freely Avoid overpressure and underpressure in the room where the unit has been installed Make sure...

Page 10: ...supply Maintenance and Service s s s 4 heating with room thermostat accessories The unit runs fully automatically with the temperature which has been pre selected on the room thermostat 1 Remove the...

Page 11: ...d and the burner is to be adjusted Observe regular maintenance and care intervals Cleaning the burner Clean the components of the burner as described below s s s 1 Pull the photocell 1 from its mount...

Page 12: ...he main filter frequently becomes dirty n If condensation water accumulates in the fuel Please proceed in the following way when cleaning the fuel tank 1 Unscrew the discharging screw D and discharge...

Page 13: ...rried out by authorised qualified techni cians CAUTION An electrical safety check must be carried out in accordance with VDE 0701 after any work on the units CAUTION Never let the pump run without fee...

Page 14: ...industrial or com mercial use no private living area heating The unit may be operated only by accordingly trained personnel The manufacturer is not liable for damage that occurs due to nonob servance...

Page 15: ...ith clean fuel 10 Fuel filter is blocked dirty Clean fuel filter resp replace if necessary 11 Nozzle is blocked resp wrong dimension type size Replace nozzle take care of correct type and size 12 Wron...

Page 16: ...nical progress 51 50 54 52 56 55 58 57 64 65 66 67 59 52 53 61 62 38 58 56 55 63 Siehe Abb AA 96 38 32 40 39 39 41 32 42 34 85 36 35 37 01 02 03 04 05 04 03 26 27 28 29 31 30 A B 32 34 34 33 97 08 98...

Page 17: ...4 72 Relay socket 1102534 29 Fan housing 1103734 73 Automatic burner 1102239 30 Air baffle plate right 1103756 74 Locking screw PG plate 1102533 31 Air baffle plate left 1103757 75 O ring seal 1103783...

Page 18: ...ate Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Model Model No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Clean unit surface Clean unit interior Clean fan blade Cle...

Page 19: ...x l h 2 45 Nozzle Danfoss 80 H USG 0 50 Pump pressure approx bar 11 to 12 Tank capacity Ltr 40 Electrical connection 1 V 230 Frequency Hz 50 Rated current max A 2 3 Power consumption max 1 kW 0 43 Fus...