background image

REMKO ATK 25

Automatic oil heater
with built-in oil burner, tank
and exhaust gas connection

Operation · Technology · Spare Parts

Edition GB-D05

Summary of Contents for ATK 25

Page 1: ...REMKO ATK 25 Automatic oil heater with built in oil burner tank and exhaust gas connection Operation Technology Spare Parts Edition GB D05...

Page 2: ......

Page 3: ...4 Intended use 14 Electrical Wiring Diagram 14 Trouble Shooting 15 Exploded view 16 Spare Parts List 17 Maintenance log 18 Technical Data 19 Before commissioning use of the equipment these operating i...

Page 4: ...s operation The unit must be set up and operated in such a way that people are not endangered by exhaust fumes and radiated heat and no fires can break out The unit may be set up and operated in rooms...

Page 5: ...t the automatic tank heater is activated for tempe ratures below 10 C When the unit has been switched on or when heat is required auto matic function with room thermo stat the supply air fan starts Th...

Page 6: ...is the case if e g 1 The room contents in m corre spond with at least 30 times the nominal heat output of all units operating in the room and a natural change of air is ensured through windows and doo...

Page 7: ...air supply appropriate to the respective forced air burner capacity see name plate Outdoor mounting Due to the operation of the unit no dangers or unreasonable nuisances may arise The unit operator mu...

Page 8: ...doors or in open rooms the operation of the device is also possible without an exhaust system However we recommend a 1 m exhaust pipe see example 2 with a rain hood placed on top so as to rule out the...

Page 9: ...Make sure that combustion air is supplied Make sure that the air can be sucked in and be exhausted freely Avoid overpressure and underpressure in the room where the unit has been installed Make sure...

Page 10: ...supply Maintenance and Service s s s 4 heating with room thermostat accessories The unit runs fully automatically with the temperature which has been pre selected on the room thermostat 1 Remove the...

Page 11: ...d and the burner is to be adjusted Observe regular maintenance and care intervals Cleaning the burner Clean the components of the burner as described below s s s 1 Pull the photocell 1 from its mount...

Page 12: ...he main filter frequently becomes dirty n If condensation water accumulates in the fuel Please proceed in the following way when cleaning the fuel tank 1 Unscrew the discharging screw D and discharge...

Page 13: ...rried out by authorised qualified techni cians CAUTION An electrical safety check must be carried out in accordance with VDE 0701 after any work on the units CAUTION Never let the pump run without fee...

Page 14: ...industrial or com mercial use no private living area heating The unit may be operated only by accordingly trained personnel The manufacturer is not liable for damage that occurs due to nonob servance...

Page 15: ...ith clean fuel 10 Fuel filter is blocked dirty Clean fuel filter resp replace if necessary 11 Nozzle is blocked resp wrong dimension type size Replace nozzle take care of correct type and size 12 Wron...

Page 16: ...nical progress 51 50 54 52 56 55 58 57 64 65 66 67 59 52 53 61 62 38 58 56 55 63 Siehe Abb AA 96 38 32 40 39 39 41 32 42 34 85 36 35 37 01 02 03 04 05 04 03 26 27 28 29 31 30 A B 32 34 34 33 97 08 98...

Page 17: ...4 72 Relay socket 1102534 29 Fan housing 1103734 73 Automatic burner 1102239 30 Air baffle plate right 1103756 74 Locking screw PG plate 1102533 31 Air baffle plate left 1103757 75 O ring seal 1103783...

Page 18: ...ate Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Model Model No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Clean unit surface Clean unit interior Clean fan blade Cle...

Page 19: ...x l h 2 45 Nozzle Danfoss 80 H USG 0 50 Pump pressure approx bar 11 to 12 Tank capacity Ltr 40 Electrical connection 1 V 230 Frequency Hz 50 Rated current max A 2 3 Power consumption max 1 kW 0 43 Fus...

Page 20: ...and abroad but also unusually highly qualified sales experts REMKO sales representatives are more than just salespeople they must also be customer consultants in air conditioning and heating technolo...