Parameter
Text display
Description
Factory
setting
AP074
Force summer mode
The heating is stopped. Hot water is maintained. Force Summer Mode
Adjustment range:
0 =Off
1 =On
0
AP079
Building Inertia
Inertia of the building used for heat up speed
Adjustment range:
from 0 to 10
3
AP080
Frost min out temp
Outside temperature below which the antifreeze protection is activated
Adjustment range:
from -30 °C to 20 °C
-10
AP091
Outside Sens. Source Type of outside sensor connection to be used
Adjustment range:
0 =Auto
1 =Wired sensor
2 =Wireless sensor
3 =Internet measured
4 =None
0
AP077
Max. display level
Maximum Level of parameters and signals to display on MK
Adjustment range:
1 =End user
2 =Installer
3 =Installer advanced
4 =Lab
5 =Controls Development
2
9.11 Reading out measured values
9.11.1 Control unit counters
Tab.39 Navigation for basic installer level
Level
Menu path
Basic installer
> Installation Setup > CU-GH08 > Submenu
> Parameters, counters, signals > Counters
(1) See the column "Submenu" in the following table for the correct navigation. The counters are grouped in specific functionalities.
Tab.40 Counters at basic installer level
Code
Display text
Description
Range
Submenu
AC005
CH Energy
Consumed
Energy consumed for central
heating
0 kWh - 4294967294
kWh
Gas fired appliance
AC006
DHW Energy
Consumed
Energy consumed for domestic
hot water
0 kWh - 4294967294
kWh
Gas fired appliance
Tab.41 Navigation for installer level
Level
Menu path
Installer
> Installation Setup > CU-GH08 > Submenu
> Parameters, counters, signals > Counters
(1) See the column "Submenu" in the following table for the correct navigation. The counters are grouped in specific functionalities.
9 Settings
60
MID _HMI T-control - Gas 120 ACE
7717201 - v03 - 25062019