Export
EN
Independent domestic hot water tanks
BL 150...500-2
Installation, Userand ServiceManual
7607674-001-04
Page 1: ...Export EN Independent domestic hot water tanks BL 150 500 2 Installation User and Service Manual 7607674 001 04...
Page 2: ...ertifications 8 2 3 2 Directive 97 23 EC 8 3 Technical description 9 3 1 General description 9 3 2 Technical specifications 10 3 2 1 Characteristics of the DHW calorifier 10 4 Installation 11 4 1 Regu...
Page 3: ...1 5 3 Drinking water quality 22 6 Checking and maintenance 23 6 1 General instructions 23 6 2 Checking the safety valve or unit 23 6 3 Cleaning the casing material 23 6 4 Checking the magnesium anode...
Page 4: ...3 18 11 2015 7607674 001 04...
Page 5: ...ance Cleaning and user maintenance shall not be made by children without supervision CAUTION 4 In order to limit the risk of being scalded the installation of a thermostatic mixing valve on the domest...
Page 6: ...ediately replace damaged or illegible instructions and warning stickers 1 3 Liabilities 1 3 1 Manufacturer s liability Our products are manufactured in compliance with the requirements of the various...
Page 7: ...n to check the appliance and maintain it in good working order 4 Give all the instruction manuals to the user 1 3 3 User s liability To guarantee optimum operation of the appliance the user must respe...
Page 8: ...serious physical injury WARNING Risk of a dangerous situation causing slight physical injury CAUTION Risk of material damage Signals important information Signals a referral to other instructions or o...
Page 9: ...rence Standard EN 60 335 1 Reference Standard EN 60 335 2 21 4 2004 108 EC Electromagnetic Compatibility Directive Reference Standards EN 50 081 1 EN 50 082 1 EN 55 014 2 3 2 Directive 97 23 EC This p...
Page 10: ...d with food quality standard enamel vitrified at 850 C which protects the tank from corrosion 4 The heat exchanger welded into the tank is made of smooth tubing the external surface of which which is...
Page 11: ...0 1 10 1 10 Water content litres 145 195 295 390 495 Weight DHW calorifiers kg 76 89 111 144 171 Performances related to the type of appliance Power exchanged 1 kW 26 33 39 56 66 Flow per hour T 35 C...
Page 12: ...mind you that the maximum domestic hot water temperature at the draw off point is subject to particular regulations in the various countries where the appliance is sold in order to protect the consume...
Page 13: ...lace the appliance as close as possible to draw off points in order to minimise energy losses through the pipes 4 Place the appliance on a base frame to facilitate cleaning of the premises 4 Install t...
Page 14: ...0 70 70 66 71 B 282 282 282 284 283 C 567 657 747 838 896 D 662 840 1142 1157 1213 E 844 1114 1634 1510 1618 F 605 605 605 705 755 G 944 1212 1734 1622 1740 n BL 150 2 G F A B C D E 1 2 3 4 5 C003692...
Page 15: ...he packaging from the DHW calorifier leaving the calorifier on the pallet used for transport 2 Remove the protective packaging 3 Remove the 3 screws securing the calorifier to the pallet 4 Lift the DH...
Page 16: ...TION Do not place the blocks on the exterior sides of the domestic hot water calorifier 4 6 Fitting the DHW sensor C003702 C 1 3 2 1 Insert the sensor into the sensor tube with the help of the sensor...
Page 17: ...water inlet 29 Pressure reducer 30 Safety unit 32 D H W loop back pump 33 DHW temperature sensor 44 Thermostat limiting the temperature to 65 C with manual reset for underfloor heating 46 3 way direc...
Page 18: ...tanding boiler 68 9 9 27 27 32 33 25 56 L000369 B 24 30 50 50Hz 230V 46 16 64 67 B A 11 21 27 9 1 4 2 3 50 18 9 9 9 9 9 27 27 32 16 33 25 26 56 57 21 50Hz 230V 7 2 3 4 1 7 17 65 9 9 52 11 10 27 C C 23...
Page 19: ...c connection of 150 l to 300 l tanks and the boiler right or left we offer optional hydraulic connection kits For connection using these kits refer to the instructions delivered with them 4 8 2 Connec...
Page 20: ...nit must have a continuous and sufficient gradient 4 The cross section of the discharge pipe from the safety unit must be at least equal to the cross section of the opening of the safety unit outlet n...
Page 21: ...MPa a pressure reducer must be installed upstream of the appliance Install the pressure reducer downstream the water meter in such a way as to ensure the same pressure in all of the installation pipes...
Page 22: ...than or equal to 70 4 65 60 60 5 2 Putting the appliance into operation CAUTION Initial commissioning must be done by a qualified professional 1 Flush the domestic circuit and fill the calorifer thro...
Page 23: ...g water quality In regions where the water is very hard TH 20 f we recommend fitting a softener The hardness of the water must always be between 12 f and 20 f to be capable of providing effective prot...
Page 24: ...e casing material Clean the outside of appliances using a damp cloth and a mild detergent 6 4 Checking the magnesium anode Check the condition of the anode at the end of the first year After the first...
Page 25: ...nd improves the insulation of the DHW calorifier 4 Remove limescale deposits from the exchanger to guarantee its performance 5 Fit the unit together See chapter Remounting the inspection hatches page...
Page 26: ...oad 8 N m The flange mounting bolts must not be excessively tight Flange Torque load Lip gasket 6 N m 1 0 Sheet gasket 15 N m Approximately 6 N m is obtained by manipulating the box spanner with the s...
Page 27: ...e form No _____ Date _________ Checks made ______________________________ Remarks _____________________ By _______________ Signature ____________ BL 150 500 2 6 Checking and maintenance 18 11 2015 760...
Page 28: ...ral terms and conditions of sale and delivery Always ensure that your return package is accompanied by the completed return form see attached example In this way your supplier can fulfil his warranty...
Page 29: ...860646 Adjustable foot M10 x 35 x x x x x 2 95365613 Contact spring for pocket x x x x x 3 200021501 Inspection trap screws x x x x x 4 95014035 Seal 35 x 8 5 x 2 x x x x x 5 94974527 Nylon brace x x...
Page 30: ...8912 Complete anode diameter 33 mm length 290 mm 1x For top trap x 13 89608950 Complete anode diameter 33 mm length 420 mm 1x For top trap x x x 13 89628562 Complete anode diameter 33 mm length 450 mm...
Page 31: ...manufacturer shall not be held responsible for any damage loss or injury caused by installations which do not comply with the following 4 applicable local laws and regulations 4 specific requirements...
Page 32: ...en Appendix Information on the ecodesign and energy labelling directives...
Page 33: ...fic information 3 1 1 Recommendations 3 1 2 Ecodesign Directive 3 1 3 Technical data Hot water storage tank 3 1 4 Disposal and Recycling 3 1 5 Product fiche Hot water storage tanks 3 Contents 2 760767...
Page 34: ...tic hot water tank must be car ried out by a qualified installer in accordance with local and nation al regulations 1 Cut the electricity to the domestic hot water tank 2 Disconnect the cables on the...
Page 35: ......
Page 36: ...ological information contained in these technical instructions as well as any drawings and technical descriptions supplied remain our property and shall not be multiplied without our prior consent in...