DHW outlet (cold)
ø 15 mm
gas connection
ø 22 mm
condensate drain connection
3/4" (standard overflow pipe size)
DHW outlet (hot)
ø 15 mm
Flow connection
ø 22 mm
return connection
ø 22 mm
158 mm
pipe safety valve
ø 15 mm
LTALW7H000102b
Flue / Air inlet connection
ø 60 / 100 mm
1
Check box contents. Ensure that all components are included. Report incomplete delivery to Broag.
LTALW7H000103a
Copper tails
LTALW7H000104b
LTALW7H000131a
4x
4x
4x
LTALW7H000108a
LTALW7H000109a
Instructie service
AvantaPlus
LTALW7H000110a
LTALW7H000111a
LTALW7H000135a
Plea
se fi
rst r
ead
the
instr
uctio
ns
give
n on
this
tem
plate
befo
re in
stall
ing
the
Ava
nta
Plus
MO
UNT
ING
AVA
NTA
PLU
S
WIT
H O
PTIO
NAL
STA
ND
OFF
FRA
ME
158
mm
LTAL
W7H
0001
02a
LTALW7H000121a
LTALW7H000122a
4
ø10 mm
ø10 mm
ø8 mm
1
2
3
LTALW7H000124b
X9
8
7
LTALW7H000126a
LTALW7H000127a
X2
LTALW7H000130a
LTALW7H000129a
Mounting frame + Stand off frame
(including isolation valve set and washers)
Avanta Plus
(including pressure gauge and safety
valve)
Installation and service
manual
This document contains useful
and important information for the
correct installation, operation and
maintenance. Keep the Installation
and service manual in a safe
place together with the other boiler
documents.
Nylon plugs and screws for
fixing mounting frame
Users guide
Reed the instructions carefully and
keep the document in a safe place.
Short users guide
Boiler Log Book and warranty
card.
See that the Boiler Logbook has been
completed by the engineer at each
service and keep it in a safe place.
DHW inlet
(cold) valve set
2
Mounting Avanta Plus
Connecting OpenTherm room controls
(e.g. the Remeha Celcia 15 or 20):
Mount the control in a reference room (usually the living room).
Connect the two-wire interface cables to connectors 7 and 8 of the X9
terminal strip. When using the Celcia 20 it is possible to add the outside
sensor to provide weather compensation with room adjustment.
Connect the outside sensor to connectors 1 and 2 of the X9 terminal strip.
2.
Drill the (Ø 10 mm) holes; Fit the (Ø 10 mm)
plugs; Fit (Ø 8 mm) screws into the plugs;
Check the stand off frame is level and tighten the
screws; Fit the DHW inlet (cold) valve set to the
mounting plate.
3.
Fit fibre Washers on HTG Valves.
Suspend the boiler on mounting plate.
3
Connecting external controls
1.
Using the template determine and mark the position
of the
four
mounting holes, making sure the plate is
absolutely level.
4.
Connect the valves to the boiler
remembering to fit fibre washers supplied.
Connect the supplied copper tails to the
isolating valves.
* shown pipework is optional
Connecting the
(optional)
two channel time clock.
• Live 230 V supply for the time clock - connect to connectors 1 (N) and
2 (L) on X2 terminal strip.
• For HTG - connect the 230 V output from time clock to connector 5 and
remove exist link between connectors 1 and 4 of the X2 terminal strip.
• For DHW - connect the 230 V output from time clock to connector 3
remove exist link between connectors 3 and 4 of the X2 terminal strip.
4
Hang up the
Short users guide
Hang this card underneath or close to the boiler.
Based on the guidelines and the required installation space, determine where to mount the Remeha Avanta Plus. In determining the boiler position, consider carefully the flue outlet position and any pluming consequences.
Read the Installation and service manual for more details and regulations for mounting the Avanta Plus.
LTALW7H000123a
LTALW7H000133a
MOUNTING AVANTA PLUS
Please read the instructions given on this template
before installing the Avanta Plus.
WITH OPTIONAL STAND OFF FRAME