91424
25
MAINTENANCE/ADJUSTMENT PROCEDURE
CLEARING EVAPORATOR FREEZE-UP
WARNING: Tp prevent possible injury, do not stick fingers or hands into icemaker nozzle
or hopper with power applied to unit.
1. Remove the lower front louvered panel.
2. Put the stop/run switch in the “stop”position.
3. Close the water supply valve to the icemaker.
4. Open the hinged top cabinet.
5. Remove the ice drop and hopper covers.
6. Depress the flush switch push button on the electrical control box and drain the evaporator.
7. Pour hot water into the evaporator ice exit opening. It will be necessary to use either a funnel or a container
with a spout. Fill the evaporator completely.
8. Drain the evaporator. Repeat steps 6 and 7, as required, to insure that all of the ice in the evaporator is
melted.
9. Open the water supply valve and refill evaporator.
10. Replace the ice drop and hopper covers.
11. Consult the TROUBLESHOOTING GUIDE to determine cause of freeze-up before putting unit back in ser-
vice.
CLEANING / REPLACING THE FILTER
1. The air filter is located behind the lower front louvered panel. Remove this panel by lifting up and pulling
forward.
2. Remove the filter by sliding it toward the right side of the unit.
3. Wash the filter in a solution of warm water and a mild detergent. Do not use caustic detergent, as they may
attack the aluminum filter elements.
4. For maximum effectiveness, reactivate the filter with an air filter coating. (See PARTS LIST, Miscellaneous
Components.)
CLEANING THE CONDENSER (AIR-COOLED UNIT)
1. Disconnect power to the unit.
2. Remove the lower front and left aide louvered panels.
3. Remove all dirt/foreign material built up from the condenser fins. Be careful not to damage the fins. It is
recommended that a power vacuum cleaner with a “crevice”tool attachment be used.