Page 1: ...R INC 1994 Part No 91772 Revised August 1995 THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before installing or operating this equipment Distributed By Commercia...

Page 2: ...ND OPERATING INSTRUCTIONS 13 CLEANING INSTRUCTIONS 14 DISPENSER 14 BEVERAGE SYSTEM 14 TROUBLESHOOTING GUIDE 16 BLOWN FUSE OR CIRCUIT BREAKER 16 GATE DOES NOT OPEN 16 GATE DOES NOT OPEN OR IS SLUGGISH...

Page 3: ...11 SOLENOID ASSEMBLY EXPLODED VIEW PARTS LIST 18 FIGURE 12 EXPLODED VIEW PART LIST DB90 B 19 FIGURE 13 EXPLODED VIEW PART LIST DB90 BZ NO SINK 20 FIGURE 14 EXPLODED VIEW PARTS LIST DB90 BC MERCHANDIS...

Page 4: ...id is properly installed to prevent unautho rized access to the hopper interior and possible contamination of ice ALWAYS be sure the upper and lower front panels are securely fastened ALWAYS keep area...

Page 5: ...r with no additional cooling required IMPORTANT For dispensing Scotsman pellet style ice Model MH750 icemakers REMCOR Kit 02234 Ice Diverter must be installed on the dispenser See INSTALLATION INSTRUC...

Page 6: ...N ASSEMBLY Connect the drain tube to an open drain Additional drain tubing is provided with the unit The drain line must continuously pitch downward away from the unit and contain no traps or im prope...

Page 7: ...ower to dispenser 2 Remove upper front panel from dispenser 3 Remove ice chute and discard Gate Restrictor 4 Reinstall front panel and energize unit STORAGE HOPPER GATE MOUNTING PLATE ICE DIVERTER P N...

Page 8: ...e plate may be removed entirely for maximum ice flow For glasses and cups the plate may be adjusted downward to reduce the flow of ice The best position depends on the type of ice being used and the s...

Page 9: ...ottom needed for utilities and beverage tubing 1 1 32 IN 4 1 2 IN 11 1 4 IN 2 19 64 IN 1 7 64 IN 24 5 16 IN 29 3 4 IN 13 3 4 IN 1 3 64 IN 15 27 32 IN REAR OPENING FOR BEVERAGE AND UTILITIES OUTLINE OF...

Page 10: ...reas indicate openings in cabinet bottom needed for utilities and beverage tubing 15 1 16 IN 4 1 2 IN 21 1 16 IN 8 IN 4 IN 16 IN REAR OPENING FOR BEVERAGE AND UTILITIES OUTLINE OF UNIT FIGURE 4 MOUNTI...

Page 11: ...ngs in cabinet bottom needed for utilities and beverage tubing 10 IN 2 57 64 IN 2 1 2 IN 24 5 16 IN 29 3 4 IN 13 1 2 IN 1 3 64 IN 15 27 32 IN REAR OPENING FOR BEVERAGE AND UTILITIES OUTLINE OF UNIT 3...

Page 12: ...9 91772 3 8 4 PLCS FIGURE 6 MOUNTING TEMPLATE DB90 BCZ...

Page 13: ...10 91772 FIGURE 7 BEVERAGE SYSTEM SCHEMATIC B AND BZ UNITS...

Page 14: ...11 91772 FIGURE 8 BEVERAGE SYSTEM SCHEMATIC BC MODEL 4 VALVE...

Page 15: ...12 91772 FIGURE 9 BEVERAGE SYSTEM SCHEMATIC BC MODEL 5 VALVE...

Page 16: ...s neces sary to refill and replace the lid Allow 10 to 15 minutes for the cold plate to cool down Repeat this procedure whenever the dispenser has been standing overnight or other long periods without...

Page 17: ...Flex sides outward to disengage lower pins B Lift Ice Chute cover to disengage upper pins C Lower Ice Chute cover down out of unit Note it may be helpful to twist cover slightly 8 Clean the inside of...

Page 18: ...faucet Flush at least 2 cups of liquid to insure that the sanitizing solution has filled the entire length of the syrup lines E Disconnect the sanitizing tank Hook up the product tank to the syrup li...

Page 19: ...ce solidified in hopper B Defective agitator motor C Defective capacitor ICE DISPENSES CONTINUOUSLY A Stuck or bent push button does not release switch B Defective dispensing switch C Improper switch...

Page 20: ...17 91772 WHEN REPLACING SOLENOID ADJUST TO 7 8 INCH AS SHOWN BEFORE TIGHT ENING MOUNTING SCREWS FIGURE 10 WIRING DIAGRAM DB 90 DISPENSER...

Page 21: ...n 8 10080 1 Gate Lift Rod 9 10081 1 Gate Lift Rod Bushing 10 50754 1 Gate Arm Bearing 11 21492 1 Gate lift Arm 12 70043 1 Flatwasher 13 70422 1 Spring 14 70263 1 1 4 20 x 3 4 Hex Hd Screw 15 70048 1 1...

Page 22: ...5 Agitator Motor 7 50454 Motor Shaft Seal 8 52054 Lid 9 50751 Ice chute 10 51891 Gate Gasket 11 30997 Capacitor Agitator Motor 12 31093 Gate Solenoid Assembly See page 18 13 31551 Gate Solenoid Kit 14...

Page 23: ...31091 Transformer B Models 6 32745 Agitator Motor 7 50454 Motor Shaft Seal 8 52054 Lid 9 53015 Ice Chute back section 53016 Ice Chute Cover 10 51891 Gate Gasket 11 30997 Capacitor Agitator Motor 12 3...

Page 24: ...ERCHANDISER SECTION Item No Part No Name 1 52068 Merchandiser Panel Plexiglass 2 27685 Bracket Upper Merchandiser 3 28326 Merchandiser 4 32763 Ice Dispenser Switch 5 91511 Switch Label 6 32322 Cord Li...

Page 25: ...noid Assembly 9 22081 Gate Restrictor 10 28328 Lower SS Panel 11 51891 Gate Gasket 12 52053 Ice Chute Conduit 13 53015 Ice Chute Back Section 53016 Ice Chute Cover 14 50454 Agitator Motor Shaft Seal 1...

Page 26: ...Sink 4 27621 Sink Extension 5 51801 Gasket Cold Plate Drain Tube 6 51775 90 PVC Fitting 7 70350 Clamp Hose 8 28411 Base Cabinet 9 28840 Beverage Panel 10 52225 Cold Plate Cover 11 33035 Cord Power Sup...

Page 27: ...24 91772 FIGURE 17 EXPLODED VIEW PARTS LIST DB90 BC ELECTRIC BOX ASSEMBLY Item No Part No Name 1 31621 Ballast 2 31620 Starter 3 30997 Capacitor 4 31363 Transformer Assembly...

Page 28: ...D FAX 55 21 593 1829 ENGLAND D TYTHING ROAD ALCESTER D WARWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170 DEUIL LA BARRE D PARIS FRANCE D 33 1...

Page 29: ...HEADQUARTERS Remcor Incorporated 500 Regency Drive Glendale Heights IL 60139 708 980 6900 Distributed By Commercial Refrigeration Service Inc WWW CorneliusParts COM WWW IceCubes NET 866 423 6253 623...