2
91792
ICE MAKER
REMCOR “K”Model Ice/Beverage dispensers are designed to be used with one of several type top mount ice-
makers. These must be obtained from the appropriate manufacturer.
Check with your REMCOR Sales Coordinator for a list of icemaker kits available. This kit will contain parts and
instructions necessary to connect the icemaker to the ice dispenser.
INSTALLATION INSTRUCTIONS
1. The ice dispenser
must be sealed
to the counter. The template drawing (See Figure 2) indicates openings
which must be cut in the counter. Locate the desired position for the dispenser, then mark the outline di-
mensions and cut out locations using the template drawings. Cut openings in the counter.
Apply a continuous bead of NSF
International
(NSF) listed silastic sealant (Dow 732 or equal) approximate-
ly 1/4”inside of the unit outline dimensions and around all openings. Do not apply to the sink area until all
plumbing connections are ;made and sink is reinstalled. Then position the unit on the counter within the
outline dimensions. All excess sealant must be wiped away immediately.
2. This work should be done by a qualified service person. With the lower panel and sink removed, pull the
beverage lines up through the front opening in the bottom of the unit and make the connections using the
plumbing schematics (See Figures 5, 6, and 7) or inside the lower panel. Connect the drain line to the sink
line elbow.
3. Route drain line and power cord through the bottom opening. Reinstall the sink on the unit.
4. “K”Models only: Install ice maker according to instructions supplied with kit and manufacturer’s instructions
supplied with ice maker.
5. Connect the drain tube to an open drain. If additional piping is required, it must be 3/4”IPS (or equal) and
must pitch downward away from the unit for proper drainage.
6. Optional: Utilities routing may be made through the rear of the cabinet by removing the plastic rear panel,
plastic plug and removing the knockout for the drain hose.
A. 90
°
sink fittings can be replaced with a straight stainless steel fitting and extra drain tube length added
as required.
B. Run power cord out of opening next to knock-out. (Use Remcor bushing, part number 51913).
7. Clean the hopper interior (See CLEANING INSTRUCTIONS on pages 10 and 11).
8. Connect the power cord to a 115 volt, 60 cycle, 3-wire grounded receptacle. All electrical wiring must con-
form to national and local electrical codes.
NOTE: Water pipe connections and fixtures directly connected to a potable water supply shall be
sized, installed and maintained according to Federal, State, and Local Laws.