  Protect the thermometer from overheating, undercooling and moisture penetration 

inside the thermometer. Do not heat the thermometer over 70⁰C . 

       The power level

 of the signal

 radiated by the thermometer does not exceed the 

established  norms.  But  the  thermometer  may  be  sensitive  to  electromagnetic 

interference generated by other devices. It is therefore recommended to avoid working 

in  close  proximity  to  the  thermometer  electronic  devices  that  generate  strong 

electromagnetic field.

    Do not attempt to repair the thermometer

 by yourself

. This can result in inaccurate 

readings or thermometer failure.

       

If the thermometer is not used for a long time the 

battery should be removed and 

stored separately.

     Observe polarity when replacing the battery. 

    Lithium battery and the device itself should be disposed of

f

 in accordance with local 

regulations and not

 be thrown away

 with household waste.

    Run the Application by clicking on the button in the center 

of the screen.
 

Turn

ing

 on/off the thermometer

    

To turn the thermometer on press 

the button "on/off"

 on 

the 

 thermometer.

   To turn off the thermometer press the button "on/off"

 on 

the thermometer once again 

or in 

the

 Mobile Application.

    

Operational m

odes of the thermometer:

  

  "

Device s

earch"- 

the

 Indicator emits

 double

 light 

im

pulses 

of the 

green

 colour

.

    "Measurement  mode  and  data  transmission"  –  the 

Indicator emits short single 

im

pulse

s of the green

 color.

  Operational time in the “Device search mode” till automatic 

switching-off

  equals

 180 seconds.

 

The

  the

rmometer  RELSIB  WT51 

is  a

 

modern

,  accurate  and  s

afe

 

device

 

for

 

temperature measurement. Before work

ing

 with 

the

 thermometer read carefully the 

recommendations  for  use.  This  will  allow  to  avoid  mistakes  during  operation  and 

measurements, and become familiar with its capabilities.

   

The

 thermometer

 is

 designed to measure temperature of liquid, granular and gaseous 

media  in  a  wide  range,  with  the 

capa

bility  of 

signaling, 

monitoring  and  data 

presentation 

in

 the form of 

a graph, data archiving and send

ing

 them via e-mail.

   The compact size of the thermometer allows 

it 

to

 be

 always with you and solve all the 

problems with measur

ing

 temperature at work and at home.

   The thermometer can only be used in conjunction with a mobile device having 

the 

wireless  interface  Bluetooth  4.0  and  running 

under 

the  operating  system  iOS  or 

Android. As a rule, 

smartphone or 

tablet 

is used 

in the role of the mobile device to 

operate 

with 

the  thermometer. 

Special  software  -  a  Mobile  Application  is  used  t

display the measured temperature. 

The Application is used for linking the thermometer 

up to the mobile device and its control. 

1. 

Electronic t

hermometer RELSIB W

T

51;

2. 

C

ase for storage and transport

ation

 of the thermometer;

3. 

L

ithium 

b

attery C

R

2032;

4. Coloured markers - 6 

p

cs;

5. 

K

ey 

for

 the battery

 replacement

;

6. 

Holder

 for mounting the thermometer; 

7. Instructions for use;

8. Warranty card.

 

Connecting the thermometer to 

a

 

mobile 

device:

     Connect the thermometer to 

a

 smartphone 

in the 

follow

ing way

: click on the " + " 

button and then on the settings 

screen

 of the thermometer select "Thermometer".

   Select the 

S

earch ID on the options 

screen

 of the thermometer, and then in the search 

box click on the right thermometer.

    Enter 

a

 name of the thermometer and choose a color for the marker. 

The thermometer can be used:

Turning on 

by 

press

ing the

button

Connection with a 

mobile device

Automatic 

switching-off the 

thermometer 

180 

sec

оff

о

n

www.relsib.com

In industry and 

agriculture

In everyday life, including 

for measuring the 

temperature 

of

 food

In 

R&D

Set

3

5

Preparation for work

6

The settings of the thermometer

2

    Designation

ELECTRONIC 

THERMOMETER

RELSIB 

WT51

               I

nstruction

s

 for use 

                   РЭЛС.421413.042 И1

In 

R&D

In everyday life, including 
for measuring the temperature 

of

 food

In industry and 
agriculture

1

4

Security measures

Instruction

s

 for use

Make sure

 that Bluetooth i

s turned on 

at the mobile device

 ( for Android version 6.0 

and 

higher

 turn on Geolocation)

Download 

the

 Mobile App

lication

 "Thermometer Relsib" or "Thermometer 

Smart 

F

amily" (universal mode) 

either 

from the manufacturer's website or the 

Internet

 

resource App Store or Google Play

.

Install the Application on your mobile device

.

Insert the lithium battery CR2032 in the thermometer.

Attach 

a marker of a preferred colour

 to the cap of the thermometer. Marker

 is

 

required for identification of

 the

 thermometer when 

several

 thermometers 

are used 

at the same time.

   If necessary, set the upper and lower temperature 

limits 

and enable the 

signaling

.

    If the thermometer is successfully connected, a screen with the factory settings of the 

connected device will be displayed on the smartphone.

   By clicking on the return icon, go to the thermometer settings screen.

   

 Cannot connect to the device?

    Possible causes and their solutions:

1. The battery has failed - replace the 

battery

.

2.The thermometer works with another device or 

the 

other Mobile Application 

in

 your 

device - turn off

 all

 other running Applications and devices.

3. Bluetooth

 or Geolocation is not 

enabled - turn on Bluetooth and Geolocation.

installing/replacing the

 lithium

 battery 

installation of the marker