Protect the thermometer from overheating, undercooling and moisture penetration
inside the thermometer. Do not heat the thermometer over 70⁰C .
The power level
of the signal
radiated by the thermometer does not exceed the
established norms. But the thermometer may be sensitive to electromagnetic
interference generated by other devices. It is therefore recommended to avoid working
in close proximity to the thermometer electronic devices that generate strong
electromagnetic field.
Do not attempt to repair the thermometer
by yourself
. This can result in inaccurate
readings or thermometer failure.
If the thermometer is not used for a long time the
battery should be removed and
stored separately.
Observe polarity when replacing the battery.
Lithium battery and the device itself should be disposed of
f
in accordance with local
regulations and not
be thrown away
with household waste.
Run the Application by clicking on the button in the center
of the screen.
Turn
ing
on/off the thermometer
:
To turn the thermometer on press
the button "on/off"
on
the
thermometer.
To turn off the thermometer press the button "on/off"
on
the thermometer once again
or in
the
Mobile Application.
Operational m
odes of the thermometer:
"
Device s
earch"-
the
Indicator emits
double
light
im
pulses
of the
green
colour
.
"Measurement mode and data transmission" – the
Indicator emits short single
im
pulse
s of the green
color.
Operational time in the “Device search mode” till automatic
switching-off
equals
180 seconds.
The
the
rmometer RELSIB WT51
is a
modern
, accurate and s
afe
device
for
temperature measurement. Before work
ing
with
the
thermometer read carefully the
recommendations for use. This will allow to avoid mistakes during operation and
measurements, and become familiar with its capabilities.
The
thermometer
is
designed to measure temperature of liquid, granular and gaseous
media in a wide range, with the
capa
bility of
signaling,
monitoring and data
presentation
in
the form of
a graph, data archiving and send
ing
them via e-mail.
The compact size of the thermometer allows
it
to
be
always with you and solve all the
problems with measur
ing
temperature at work and at home.
The thermometer can only be used in conjunction with a mobile device having
the
wireless interface Bluetooth 4.0 and running
under
the operating system iOS or
Android. As a rule,
a
smartphone or
a
tablet
is used
in the role of the mobile device to
operate
with
the thermometer.
Special software - a Mobile Application is used t
o
display the measured temperature.
The Application is used for linking the thermometer
up to the mobile device and its control.
1.
Electronic t
hermometer RELSIB W
T
51;
2.
C
ase for storage and transport
ation
of the thermometer;
3.
L
ithium
b
attery C
R
2032;
4. Coloured markers - 6
p
cs;
5.
K
ey
for
the battery
replacement
;
6.
Holder
for mounting the thermometer;
7. Instructions for use;
8. Warranty card.
Connecting the thermometer to
a
mobile
device:
Connect the thermometer to
a
smartphone
in the
follow
ing way
: click on the " + "
button and then on the settings
screen
of the thermometer select "Thermometer".
Select the
S
earch ID on the options
screen
of the thermometer, and then in the search
box click on the right thermometer.
Enter
a
name of the thermometer and choose a color for the marker.
The thermometer can be used:
Turning on
by
press
ing the
button
Connection with a
mobile device
Automatic
switching-off the
thermometer
180
sec
оff
о
n
www.relsib.com
In industry and
agriculture
In everyday life, including
for measuring the
temperature
of
food
In
R&D
Set
3
5
Preparation for work
6
The settings of the thermometer
2
Designation
ELECTRONIC
THERMOMETER
RELSIB
WT51
I
nstruction
s
for use
РЭЛС.421413.042 И1
In
R&D
In everyday life, including
for measuring the temperature
of
food
In industry and
agriculture
1
4
Security measures
Instruction
s
for use
Make sure
that Bluetooth i
s turned on
at the mobile device
( for Android version 6.0
and
higher
turn on Geolocation)
Download
the
Mobile App
lication
"Thermometer Relsib" or "Thermometer
Smart
F
amily" (universal mode)
either
from the manufacturer's website or the
Internet
resource App Store or Google Play
.
Install the Application on your mobile device
.
Insert the lithium battery CR2032 in the thermometer.
Attach
a marker of a preferred colour
to the cap of the thermometer. Marker
is
required for identification of
the
thermometer when
several
thermometers
are used
at the same time.
If necessary, set the upper and lower temperature
limits
and enable the
signaling
.
If the thermometer is successfully connected, a screen with the factory settings of the
connected device will be displayed on the smartphone.
By clicking on the return icon, go to the thermometer settings screen.
Cannot connect to the device?
Possible causes and their solutions:
1. The battery has failed - replace the
battery
.
2.The thermometer works with another device or
the
other Mobile Application
in
your
device - turn off
all
other running Applications and devices.
3. Bluetooth
or Geolocation is not
enabled - turn on Bluetooth and Geolocation.
installing/replacing the
lithium
battery
installation of the marker