KNG Series Trunked Radio Programming Guide
Page 22 of 57
July 2014
6.3.1.1
Define Limits of the Child Key
a.
Set the ranges of allowed Unit IDs (up to 5 ranges are allowed). Leave these fields blank
to allow all values.
b.
Set the ranges of allowed Talk Group IDs (up to 5 ranges are allowed). Leave these fields
blank to allow all values.
c.
Set the other parameter permissions, as desired.
d.
Set the maximum number of write cycles permitted. Maximum Value is 65535.
e.
Set the expiration date (default is 6 months from the current day).
f.
If only a software key is desired, select “Key Type: Software” and select a folder to save
the access key. This file may be distributed to the end-user’s computer in any typical
manner (flash drive, network transfer, etc.).
g.
If desired, check the box “Require Password” (hardware key type only). This option will
require the NeoVision ASK user to enter an 8-character randomly-generated password.
h.
Click “Create Child Key” button to create the key. The permissions, as well as
authentication data, will be saved to the key.