IMPORTANT: The water heater should be located in an area 

where leakage of the tank or connections will not result in 

damage to the area adjacent to the water heater or to lower 

floors of the structure. Due to the normal corrosive action of 

water, the tank will eventually leak after an extended period 

of time. Also any external plumbing leak, including those 

from improper installation, may cause early failure of the 

tank due to corrosion if not repaired.  If the homeowner is 

uncomfortable with making the repair a qualified technician 

should be contacted.  A suitable metal drain pan should be 

installed under the water heater as shown below, to help 

protect the property from damage which may occur from 

condensate formation or leaks in the piping connections 

or tank. The pan must limit the water level to a maximum 

depth of 1-3/4” and be two inches wider than the heater 

and piped to an adequate drain. NOTE: The pan must not 

restrict combustion air flow. Locate the water heater near a 

suitable indoor drain. Outside drains are subject to freezing 

temperatures which can obstruct the drain line. The piping 

should be at least 3/4” ID and pitched for proper drainage. 

 

METAL
DRAIN
PAN

AT LEAST 2” GREATER  THAN THE 
DIAMETER OF THE WATER HEATER.

PIPED TO AN 
ADEQUATE DRAIN

Water heater life depends upon water quality, water usage, 

water temperature and the environment in which the 

water heater is installed. Water heaters are sometimes 

installed in locations where leakage may result in property 

damage, even with the use of a drain pan piped to a 

drain. However, unanticipated damage can be reduced 

or prevented by a leak detector or water shut-off device 

used in conjunction with a piped drain pan. These devices 

are available from some plumbing supply wholesalers and 

retailers, and detect and react to leakage in various ways:
•   Sensors mounted in the drain pan that trigger an alarm 

or turn off the incoming water to the water heater when 

water is detected.

•   Sensors mounted in the drain pan that turn off the 

water supply to the entire home when water is detected 

in the drain pan.

•   Water supply shut-off devices that activate based on 

the water pressure differential between the cold water 

and hot water pipes connected to the water heater.

•   Devices that will turn off the gas supply to a gas water 

heater while at the same time shutting off its water 

supply.

REVERSE FLOW
OF GASES 

 

EXHAUST FAN

FIGURE 1.

Clearances and Accessibility                                    

NOTE: Minimum clearances from combustible materials 

are stated on the rating plate adjacent to the gas control 

valve/thermostat of the water heater.
The water heater is certified for installation on a 

combustible floor.

• 

IMPORTANT: If installing over carpeting, the carpeting 

must be protected by a metal or wood panel beneath 

the water heater. The protective panel must extend 

beyond the full width and depth of the water heater by 

at least three inches (76.2mm) in any direction; or if in 

an alcove or closet installation, the entire floor must be 

covered by the panel. 

• 

Figure 2 may be used as a reference guide to locate 

the specific clearance locations. A minimum of 24 inch-

es of front clearance should be provided for inspection 

and service. 

 

BACK

SIDES

TOP
VIEW

SIDES

VENT

FRONT
24” MINIMUM
FOR SERVICE

TOP

TO 

CEILING

FIGURE 2.

State of California                                                       

NOTE: The water heater must be braced, anchored, or 

strapped to avoid moving during an earthquake. Contact 

local utilities for code requirements in your area, visit http://

www.dsa.dgs.ca.gov,  or call 1-916-445-8100 and request 

instructions.

Summary of Contents for FVIR GAS WATER HEATER

Page 1: ...diately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal inj...

Page 2: ... 17 Combination Space Heating Potable Water System 17 18 Solar Installation 18 Important Information About this Water Heater 19 Operating Your Water Heater 20 25 White Rodgers Gas Valve Thernostat Lighting Instructions 20 RobertShaw Gas Valve Thermostat Lighting Instructions 21 Checking the Draft 21 Burner Flames 22 Emergency Shutdown 22 Water Temperature Regulation 22 23 Operational Conditions 23...

Page 3: ...ity equivalent to a licensed tradesman in the fields of plumbing air supply venting and gas supply including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters The service agency must also have a thorough understanding of this instruction manual and be able to perform repairs strictly in accordance with the servic...

Page 4: ...void all ignition sources if you smell Natural or LP gas Do not expose water heater control to excessive gas pressure Use only gas shown on rating plate Maintain required clearances to combustibles Keep ignition sources away from faucets after extended period of non use Read instruction manual before installing using or servicing water heater ...

Page 5: ...LED IN A CLOSED WATER SYSTEM M N L E P X Y MANIFOLD TUBE IGNITER WIRE MAIN BURNER PILOT TUBE THERMOCOUPLE IGNITER ROD U MANIFOLD BURNER ASSEMBLY MANIFOLD DOOR DISCHARGE PIPE DO NOT CAP OR PLUG 6 MAXIMUM AIR GAP FLOOR DRAIN GAS CONTROL KNOB WATER TEMPERATURE DIAL ADJUSTING DIAL TOP VIEW OFF POSITION PILOT POSITION ON POSITION S GAS CONTROL VALVE THERMOSTAT WHITE RODGERS GAS CONTROL KNOB WATER TEMPE...

Page 6: ... future users of this water heater will need it for future reference Service to the FVIR System should only be performed by a qualified technician Examples of a qualified technician include licensed plumbers authorized gas company personnel and authorized service personnel IMPORTANT The manufacturer and seller of this water heater will not be liable for any damages injuries or deaths caused by fai...

Page 7: ...n the area of the water heater leave the area immediately and call the fire department from a neighbor s home Do not attempt to clean the spill until all ignition sources have been extinguished Fire or Explosion Hazard WARNING Read instruction manual before installing using or servicing water heater Improper use may result in fire or explosion Maintain required clearances to combustibles Keep comb...

Page 8: ...used in conjunction with a piped drain pan These devices are available from some plumbing supply wholesalers and retailers and detect and react to leakage in various ways Sensors mounted in the drain pan that trigger an alarm or turn off the incoming water to the water heater when water is detected Sensors mounted in the drain pan that turn off the water supply to the entire home when water is det...

Page 9: ...tural gas water heater to an L P gas supply Do not connect an L P gas water heater to a natural gas supply Failure to follow these instructions can result in death explosion or carbon monoxide poisoning Explosion Hazard Gas Requirements IMPORTANT Read the rating plate to be sure the water heater is made for the type of gas you will be using in your home This information will be found on the rating...

Page 10: ... in the occurrence of a leak in the system the gas will settle at floor level Basements crawl spaces closets and areas below ground level will serve as pockets for the accumulation of gas Before lighting an L P gas water heater smell all around the appliance at floor level If you smell gas follow the instructions as given in the warning on the front page When your L P tank runs out of fuel turn of...

Page 11: ...by a qualified technician using the installation instructions Examples of a qualified technican include gas technicians authorized gas company personel and authorized service persons Failure to so do can result in death or carbon monoxide poisoning IMPORTANT Air for combustion and ventilation must not come from a corrosive atmosphere Any failure due to corrosive elements in the atmosphere is exclu...

Page 12: ...e typical examples of each method Louvers and Grilles In calculating free area for ventilation and combustion air supply openings consideration must be given to the blocking effect of protection louvers grilles and screens These devices can reduce airflow which in turn may require larger openings to achieve the required minimum free area Screens must not be smaller than 1 4 mesh If the free area t...

Page 13: ...ied by CSA International this certification applies to the vent damper device only and does not mean they are certified for use on this water heater U L recognized fuel gas and carbon monoxide CO detectors are recommended in all applications and should be installed using the manufacturer s instructions and local codes rules or regulations IMPORTANT If you lack the necessary skills required to prop...

Page 14: ...ay is clear and free of obstructions The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces Also consult local and state codes for proper chimney sizing and application or in the absence of local and state codes the National Fuel Gas Code ANSI Z223 1 NFPA 54 current edition The connector must be installed above the extreme bottom of the chimney to prevent po...

Page 15: ...e as specified under Closed System Thermal Expansion 5 Install a shut off valve in the cold water inlet line It should be located close to the water heater and be easily accessible Know the location of this valve and how to shut off the water to the heater 6 A temperature and pressure relief valve must be installed in the opening marked Temperature and Pressure T P Relief Valve on the water heater...

Page 16: ...The use of valves that may cause excessive restriction to water flow is not recommended Use only 95 5 tin antimony or other equivalent solder Any lead based solder must not be used Piping that has been treated with chromates boiler seal or other chemicals must not be used Chemicals that may contaminate the potable water supply must not be added to the piping system Closed System Thermal Expansion ...

Page 17: ...use with space heating applications If this water heater is to be used to supply both space heating and domestic potable drinking water the instructions listed below must be followed Temperature and Pressure Relief Valve Explosion Harzard Temperature pressure relief valve must comply with ANSI Z21 22 CSA 4 4 and ASME code Properly sized temperature pressure relief valve must be installed in openin...

Page 18: ...ts previously used with non potable water heating appliances when used to supply potable water Some jurisdictions may require a backflow preventer in the incoming cold water line This may cause the temperature and pressure relief valve on the water heater to discharge or weep due to expansion of the heated water A diaphragm type expansion tank suitable for potable water will normally eliminate thi...

Page 19: ...anges Questions Contact Residential Technical Assistance by referencing the phone number on the front of the Installation Instructions and Use Care Guide Installation Checklist Water Heater Location Water heater location is important and can affect system performance Please check the following Installation area free of corrosive elements and flammable materials Centrally located with the water pip...

Page 20: ... above on this label Set the thermostat to lowest setting PILOT LIGHTING Turn thermostat dial fully clockwise until it stops Push the gas control knob down slightly and turn clockwise to OFF SEE FIGURE A NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed down slightly Do not force Wait ten 10 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information...

Page 21: ...rve the pilot through the view port Do not release the reset button Repeat immediately if pilot does not light on the first try If the pilot does not light by the fourth attempt with the igniter repeat steps 4 7 Continue to hold the button for about 1 minute after the pilot is lit Release the reset button and it will pop back up Pilot should remain lit If the pilot light goes out repeat steps 3 7 ...

Page 22: ...our hot water needs a means such as a mixing valve should be used at the hot water taps used by these people or at the water heater Mixing valves are available at plumbing supply or hardware stores see Figure 14 Follow manufacturer s instructions for installation of the valves Before changing the factory setting on the thermostat see Figure 19 Using the lowest hot water temperature that meets your...

Page 23: ...e limit switch or ECO Energy Cut Off in the tank is used to shut off the unit if the water temperature exceeds 195 F 91 C The ECO is a single use switch which if activated requires complete replacement of the entire gas control valve thermostat If the ECO should activate the water heater cannot be used until the gas control valve thermostat is replaced by a qualified technician Contact your local ...

Page 24: ...e the Repair Parts Illustration section for anode rod location TEFLON is a registered trademark of E I Du Pont De Nemours and Company Draining and Flushing It is recommended that the tank be drained and flushed every 6 months to remove sediment which may build up during operation The water heater should be drained if being shut down during freezing temperatures To drain the tank perform the follow...

Page 25: ...owing maintenance procedures are for the FVIR System components and should be performed by a qualified technician Replacement parts may be ordered through your plumber or the local distributor Parts will be shipped at prevailing prices and billed accordingly When ordering replacement parts always have the following information ready 1 model serial and product number 2 type of gas 3 item number 4 p...

Page 26: ...IGURE 25 FIGURE 26 Replacing the Pilot Pilot Tube Assembly 1 Remove the manifold burner assembly See Removing the Manifold Burner Assembly 2 Lift the retainer clip straight up from the back of the two piece wire connector using a flat blade screwdriver then remove the two piece wire connector from the manifold door Figure 25 IMPORTANT Be careful not to bend or alter the position of the pilot tube ...

Page 27: ...r Assembly Replacing the Manifold Burner Assembly WARNING Explosion Hazard Tighten both manifold door screws securely Remove any fiberglass between gasket and combustion chamber Replace viewport if glass is missing or damaged Replace two piece wire connector if missing or removed Replace door gasket if damaged Failure to follow these instructions can result in death explosion or fire 1 Check the d...

Page 28: ...h or fine grit sandpaper Removing and Replacing the Gas Control Valve Thermostat IMPORTANT This water heater has a resettable thermal switch installed Do not attempt to disable or modify this feature in any way Use only factory authorized replacement parts Removing the Gas Valve 1 Turn off the gas supply to the water heater at the manual gas shut off valve This valve is typically located beside th...

Page 29: ...rmal switch TROUBLESHOOTING CHART PROBLEM POSSIBLE CAUSE S CORRECTIVE ACTION BURNER WILL NOT IGNITE 1 Pilot not lit 2 Thermostat set too low 3 No gas 4 Dirt in the gas lines 5 Pilot line clogged 6 Main burner line clogged 7 Non functioning thermocouple 8 Non functioning thermostat 9 Heater installed in a confined area 1 Light pilot 2 Turn temp dial to desired temperature 3 Check with gas utility c...

Page 30: ... inlet 8 Advise customer DRIP FROM RELIEF VALVE 1 Excessive water pressure 2 Heater stacking 3 Closed water system 1 Use a pressure reducing valve and relief valve 2 Lower the thermostat setting 3 See Closed System Thermal Expansion THERMOSTAT FAILS TO SHUT OFF 1 Thermostat not functioning prop erly 2 Improper calibration 1 Replace thermostat 2 Replace thermostat COMBUSTION ODORS 1 Insufficient se...

Page 31: ... manual for specific requirements NO Is the pilot tube damaged NO Does the flame arrestor show signs of discoloration and or debris Shut off the gas supply to the water heater at the manual gas shut off valve then contact Residential Technical Assistance by referencing the phone number on the front of the Installation Instructions and Use Care Guide YES YES YES YES YES YES YES YES YES NO Contact a...

Page 32: ...BAFFLE 4 HEAT TRAP NIPPLES COLD SOME MODELS 5 HEAT TRAP NIPPLES HOT SOME MODELS 6 COLD WATER DIP TUBE 7 ANODE ROD 8 TEMPERATURE PRESSURE RELIEF VALVE LOCATED TOP OR SIDE 9 DRAIN VALVE 10 GAS CONTROL VALVE THERMOSTAT with wire leads 11 OUTER DOOR 12 PILOT PILOT TUBE ASSEMBLY KIT Natural Gas 13 PILOT PILOT TUBE ASSEMBLY KIT L P Gas 14 BURNER Natural Gas 15 BURNER L P Gas 16 MANIFOLD DOOR ASSEMBLY Na...

Page 33: ...ocouple two piece wire connector with retainer clip thermal switch and pilot assembly Natural Gas Low Nox Item 17 Manifold door assembly which contains the manifold tube gasket door pilot tube thermocouple two piece wire connector with retainer clip thermal switch and pilot assembly L P Gas Item 18 Contains two piece wire connector and retainer clip Item 19 Contains manifold door gasket Item 20 Co...

Page 34: ...34 NOTES ...

Page 35: ...d in a non corrosive and non contaminated atmosphere used with factory approved anode s installed in its original installation location in the United States its territories or possessions and Canada sized in accordance with proper sizing techniques for residential water heaters bearing a rating plate which has not been altered defaced or removed except as required by the warrantor used in an open ...

Page 36: ...PONSIBLE FOR WATER DAMAGE LOSS OF USE OF THE UNIT INCONVENIENCE LOSS OR DAMAGE TO PERSONAL PROPERTY OR OTHER CONSEQUENTIAL DAMAGE THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS WARRANTY OR OTHERWISE FOR DAMAGE TO ANY PERSONS OR PROPERTY WHETHER DIRECT OR INDIRECT AND WHETHER ARISING IN CONTRACT OR IN TORT IF THE GLASS LINED TANK IN THIS WATER HEATER SHALL PROVE UPON EXAMINATION BY THE WARRANT...

Reviews: