Reliance HS 7000 Installation And  Operating Instructions, Owners Manual Download Page 9

AUTO
RETURN

BACK
RECLINE

BACK

RAISE

LIFT
DOWN

UP

LIFT

FIGURE 3

Footswitch Operation 

REMARQUE

 : Les interrupteurs RAISE (LEVER) et 

LOWER (BAISSER) la base sur l’interrupteur au pied 

sont programmables. Selon la conception initiale, 

le mouvement de la chaise S’ARRÊTE lorsque l’un 

ou l’autre de ces interrupteurs est relâché. Si vous 

désirez que le mouvement de la chaise CONTINUE, 

après que l’un ou l’autre de ces interrupteurs est 

relâché, consultez la section 4 pour connaître les 

instructions de programmation.

3.3.  Chair Top

3.3.1.  An electric motor supplies power for the movement 

of the chair top.

3.3.2.  Raising & Reclining the Chair Top with 

Membrane Switches.

•  The chair top may be raised or reclined by Membrane 

Switches on either side of the chair back (Figure 2).

•  To  lower,  depress  the  triangle-shaped  DOWN  arrow 

located BELOW the “TOP”. This is called the LOWER TOP 

or RECLINE switch. 

•  To raise the chair top from these switches, depress the 

triangle-shaped UP arrow located ABOVE the next “TOP”. 

This is called the RAISE TOP switch.

NOTE: 

 The RAISE and LOWER/RECLINE switches 

on the Chair Back are programmable. By design, 

the motion of the Chair will CONTINUE when either 

of these switches is released. If you want the motion 

of the Chair to STOP after either of these switches 

is released, then see Section 4 for programming 

instructions.

REMARQUE

 : Les interrupteurs RAISE (LEVER) 

et  LOWER/RECLINE  (BAISSER/INCLINER)  sur 

le  dossier  de  la  chaise  sont  programmables. 

Selon la conception initiale, le mouvement de la 

chaise  CONTINUE  lorsque  l’un  ou  l’autre  de  ces 

interrupteurs  est  relâché.  Si  vous  désirez  que 

le  mouvement  de  la  chaise  S’ARRÊTE,  après 

que  l’un  ou  l’autre  de  ces  interrupteurs  est 

relâché, consultez la section 4 pour connaître les 

instructions de programmation.

CAUTION - 

ANY chair movement that 

CONTINUES after the switch is released may 

be stopped by depressing the STOP switch 

or by depressing the same switch a second 

time.

PRÉCAUTION : 

TOUT mouvement de la 

chaise qui CONTINUE après que l’interrupteur 

est relâché peut être arrêté en appuyant sur 

l’interrupteur STOP (ARRÊT) ou en pressant le 

même interrupteur une seconde fois.

3.3.3.  Raising & Lowering the Chair Top From the 

Footswitch.

•  For operation from the footswitch (Figure 3), depress 

the right side of the left-hand pedal to raise the chair 

top.

•  Depress the left side of the left-hand pedal to lower/

recline the chair top.

NOTE:  

the RAISE and LOWER/RECLINE switches 

on  the  footswitch  are  also  programmable.  The 

motion of the chair will STOP when either of these 

switches is released. If you want the motion of the 

chair to CONTINUE after either of these switches 

is released, then see Section 4 for programming 

instructions.

IN-7000

9

Summary of Contents for HS 7000

Page 1: ...OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS MODEL 7000 LOW VOLTAGE CONTROL CHAIR For DesignerSERIES and Premiere COLLECTION Models...

Page 2: ...ERED TO ISO 13485 MADE IN AMERICA Reliance Medical Products Inc 3535 Kings Mills Road Mason Ohio 45040 2303 1 800 735 0357 www reliance medical com SERIAL NUMBER For your future reference mark the ser...

Page 3: ...t C6 Headrest 13 4 PROGRAMMING THE CHAIR 13 4 1 Safety Shutdown Feature 13 To ENTER Safety Shutdown Mode 13 To EXIT Safety Shutdown Mode 13 4 2 Individual Programming of the RAISE TOP RECLINE TOP RAIS...

Page 4: ...rtant operating and maintenance servicing instructions in this Installation and Operating Instructions REMARQUE Amplifieuneproc dure pratiqueoucondition DANGER AVERTISSEMENT ou PR CAUTION Le point d e...

Page 5: ...REE The degree of safety of application in the presence of a FLAMMABLE ANAESTHETIC MIXTURE WITH AIR or WITH OXYGEN OR NITROUS OXIDE EQUIPMENT not suitable for use in the presence of a FLAMMABLE ANAEST...

Page 6: ...to other devices in the vicinity However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to other devices whichcan...

Page 7: ...If this chair is purchased in conjunction with a Reliance instrument stand the chair control cable supplied will provide proper operation Refer to the instrument stand manual for connection to the st...

Page 8: ...ts plateaux tables emp chant le mouvement de la chaise Each time main power is applied to the chair the circuit board inside the chair will respond with a one second beep The beep indicates the electr...

Page 9: ...r either of these switches is released then see Section 4 for programming instructions REMARQUE Les interrupteurs RAISE LEVER et LOWER RECLINE BAISSER INCLINER sur le dossier de la chaise sont program...

Page 10: ...lit insuffisante CAUTION This exam Chair is designed for use with a patient properly positioned in the Chair Prior to reclining the Chair ensure that the patient is seated in the Chair and that the pa...

Page 11: ...moire ne commande pas le mouvement d l vation du dossier de la chaise 3 6 Revolving Rotation 3 6 1 The chair upper structure may be revolved 350 with a built in stop to prevent continuous rotation The...

Page 12: ...lockwise until snug See Figure 6 3 9 3 Adjustment No 18 22 Headrest 3 9 3 1 There are three adjustments provided on the No 18 22 headrest The first is the tension on the pad rotation By tightening the...

Page 13: ...the chair is functional and movement of the chair WILL OCCUR when another switch is depressed 4 1 2 4 The LED s will come back on when the chair becomes operational 4 2 Individual Programming of the R...

Page 14: ...hair The factory design is to have NO BEEP occur when a switch is depressed To change this setting the chair must be in Setup Mode See Section 4 2 4 on how to ENTER Setup Mode once in Setup Mode 4 3 2...

Page 15: ...se Base switch will function like a momentary switch 4 5 4 3 If any RAISE BASE switch is programmed for Home Mode the LED s will blink for 15 seconds after the AUTO DOWN switch is depressed When the L...

Page 16: ...E 7 AC INPUT MODULE CAUTION To avoid a bind of the Fuse Drawer within the AC Input Module never install the Fuse Drawer into the AC Input Module without fuses PR CAUTION Pour viter que le tiroir fusib...

Page 17: ...HECK FOR VOLTAGE 2 REPLACE SOLENOID COIL 3 CONTACT FACTORY CHAIR BASE WILL NOT RAISE PUMP MOTOR DOES NOT RUN 1 NO POWER TO PUMP MOTOR ASS Y 2 UP LIMIT SWITCH STUCK OPEN 3 PUMP MOTOR BURNED OUT 4 OTHER...

Page 18: ...re in cleaning and notify personnel in area of danger Wear rubber gloves during all cleaning activity Use caution in cleaning around buttons stitching and wooden or other decorative trim since these s...

Page 19: ...IN 7000 19 NOTES...

Page 20: ...es veuillez 1 Informez le distributeur ou l usine du mod le et du num ro de s rie de l ensemble Ces num ros sont de la plaque qui est situ e l arri re pr s du bas de l arri re pr sidence 2 Sp cifier l...

Page 21: ...SITION ADJUSTABLE 6 20 LIFT MODEL AND SERIAL NUMBER PLATE 1 2 5 8 9 10 6 7 3 4 11 Please specify upholstery color when ordering To order complete Upholstery Set use P N 2077873 Designer Upholstery Set...

Page 22: ...Base Assembly See Figure 11 8 3137173 Upholstered Arm Assembly Right Premiere 3 Headrest Assemblies See Figures 12 thru 18 9 3137273 Upholstered Arm Assembly Left Premiere 4 1760403 Footstep 10 31375...

Page 23: ...59 58 33 62 40 28 29 50 31 32 5 30 16 27 27 3 57 16 28 29 40 81 2 62 34 32 31 6 58 65 2 2 4 78 79 2 Per Side 73 79 2 Per Side 14 42 22 44 45 4 3 6 64 1 10 71 46 70 67 4 6 47 17 15 74 77 4 2 2 2 11 75...

Page 24: ...9 Lock Shaft 19 0411199 Fiber Washer 20 0603803 Back Hinge Assembly Right 21 0603903 Back Hinge Assembly Left 1528185 Armrest Cover 3 9 2 164389 6 Circuit Plug 24 1422492 Apron Board Assembly 25 07228...

Page 25: ...8 32 Hinge Bracket Pin 65 0603685 Apron Link 66 0125372 Back Bracket Right 67 0125472 Back Bracket Left 68 1108695 Back Angle Bracket 1 Ribb 0 Plug 0 Trua 0 Apro 1 6 Cir 0 Lock 0 S H 3 8 0 Lock 0 3 8...

Page 26: ...IN 7000 26 21 10 11 19 20 7 5 9 18 22 24 26 25 29 27 15 40 8 12 6 30 17 43 42 32 13 23 40 30 17 31 1 41 40 2 3 4 16 17 14 39 36 37 38 33 35 34 FIGURE 11 CHAIR BASE ASSEMBLY...

Page 27: ...24 1659299 Power Cord Assembly 120V US 25 1550599 Chair Control Cable LV To LV 26 1608192 Footswitch Assembly 27 1634299 Fuse 6 3 A 250V 120V 1634999 Fuse 4 A 250V 230V 28 1976799 Power Entry Module...

Page 28: ...IN 7000 28 1 2 10 9 3 4 6 5 7 8 11 41 38 26 42 40 43 20 30 31 32 33 37 34 27 28 29 35 36 12 13 15 16 19 18 14 17 25 24 23 22 21 18 39 FIGURE 12 LIFT ASSEMBLY...

Page 29: ...Ball 10 0365799 Gasket Tie Rod 31 0731199 O Ring 11 0432599 Base Column Seal 32 0441999 Valve Seat 12 0903292 Cylinder Assembly High 33 1012499 Valve Housing 0526792 Cylinder Assembly Low 34 0363299 R...

Page 30: ...mbly 2 1558897 Headrest Cover 3 1562499 3 8 Adjustable Handle 4 1558903 Mounting Plate 5 1559295 Headrest Lock Block 6 1559395 Headrest Pad Mounting Plate 7 1207199 3 4 O D x 3 8 I D x 3 4 Spacer 8 15...

Page 31: ...1 1 8 12 10 9 4 4 4 ITEM PART NO DESCRIPTION 1 0665073 Uph 10 Board Assembly 2 0574173 Pillow Assembly 10 3 0567903 High Back Cover 4 0568003 Pillow Back Cover 5 0845199 F H W S 6 x 50 Phil 6 0569699...

Page 32: ...IN 7000 32 FIGURE 15 18 22 HEADREST ASSEMBLY 1 3 5 6 9 9 2 11 8 7 13 12 14 15 16 17 4 10 18...

Page 33: ...0 24 x 3 8 12 1427099 Spring Plunger 13 1538899 Spring 14 1454999 L H C S 10 24 x 3 4 Socket 15 1434799 Pivot Cap Pad 16 0467195 Bushing 188 I D x 312 O D 17 1456199 Nut Acorn 1 4 20 Low Crown 18 1425...

Page 34: ...IN 7000 34 1 14 5 13 16 20 12 2 11 6 18 10 20 9 8 15 7 17 4 4 4 3 19 4 2 21 FIGURE 16 21 HEADREST ASSEMBLY...

Page 35: ...0 x 2 1 2 10 1526399 T H M S 5 16 18 x 1 2 11 1571799 Short Standoff 12 1559092 Stud Mount Assembly 13 0712999 F H M S 1 4 20 x 3 4 14 1559499 F H M S 3 8 16 x 3 4 15 0713199 R H M S 1 4 20 x 3 4 16 1...

Page 36: ...IN 7000 36 9 14 4 1 10 8 12 7 6 2 11 11 5 3 13 15 FIGURE 17 C6 HEADREST ASSEMBLY...

Page 37: ...S 10 24 x 50 Long 8 0527699 Washer 1 13 O D x 76 I D 2336000 Sub Assembly Lock Mechanism 9 2262299 Elevator Bar Short Bend 10 2262099 F H C S 10 24 x 63 11 0730199 Washer 312 SAE 12 2115499 O H W S w...

Page 38: ...IN 7000 38 4 6 5 10 3 7 11 9 8 4 4 1 2 FIGURE 18 30 HEADREST ASSEMBLY...

Page 39: ...8 9 10 11 0569699 O H W S 6 x 3 4 0569799 6 Finishing Washer 0557499 Mounting Plate Assembly 0123203 Bracket Cover 1111399 F H C S 1 4 20 x 3 4 Socket 0788699 S H C S 1 4 20 x 1 00 1454799 B H C S 1 4...

Page 40: ...IN 7000 40 3 14 5 13 20 12 4 11 6 18 10 19 9 8 15 7 17 4 4 2 1 2 FIGURE 19 31 HEADREST ASSEMBLY...

Page 41: ...559599 R H M S 1 4 20 x 2 1 2 10 1526399 T H M S 5 16 18 x 1 2 11 1571799 Short Standoff 12 1559092 Stud Mount Assembly 13 0712999 F H M S 1 4 20 x 3 4 14 1559499 F H M S 3 8 16 x 3 4 15 0713199 R H M...

Page 42: ...IN 7000 42 FIGURE 20 WIRING DIAGRAM...

Page 43: ...IN 7000 43...

Page 44: ...IN 7000 44 NOTES...

Page 45: ...IN 7000 45 NOTES...

Page 46: ...NOTES IN 7000 46...

Page 47: ...cordance with the appropriate instructions manual for the products Warranty will be voided if installation is performed by a non authorized individual 3 The products have not sustained breakage or oth...

Page 48: ...r Service 1 800 735 0358 Technical Service 513 398 3937 Http www reliance medical com P N 27178 REV G Copyright 2008 Printed in U S A Revised 04 2017 8920 MADE IN AMERICA EC REP Authorized European Co...

Reviews: