Model

Product Description

Listing and Approvals

NS-ASAM

Nitrogen maintenance device with automatic switchover

cULus Listed

FM Approved

NS-Pak

Single system nitrogen maintenance device with high pressure 

regulator

cULus Listed

FM Approved

Nitrogen Regulator

High-pressure regulator for connection to single or multiple pressure 

maintenance devices

N/A

Product Features

NS-ASAM

•  Designed for two separate nitrogen or air sources
•  Automatically switches between primary and secondary          
    source
•  Bypass valve provided for quick fill of system
•  Low-pressure switch for primary source
•  For use on single or multiple systems
•  Keyhole slots provided for easy wall mounting

NS-Pak

•  For bottled nitrogen use on a single system
•  Low-pressure switches for nitrogen source and system
•  Bypass valve provided for quick fill of system
•  Keyhole slots provided for easy wall mounting

Nitrogen Regulator

•  For bottled nitrogen use on single or multiple systems
•  Low-pressure switch for nitrogen source

General Description

Reliable Nitrogen Automatic Pressure Maintenance Devices 
are designed to connect nitrogen cylinders to dry pipe and 
preaction systems. The NS-ASAM is designed to connect a 
primary and secondary cylinder or bank of cylinders to sin-
gle or multiple systems, and provides automatic switchover 
between sources. The NS-Pak is a self-contained unit for con-
nection of a cylinder or bank of cylinders to a single system. 
The Nitrogen Regulator reduces cylinder pressure and can 
be connected to the A-2 Pressure Maintenance Device on 
single or multiple systems. Each device includes a low-pres-
sure switch to signal that the nitrogen source is depleting and 
needs service. High-pressure cylinders (not included) can 
typically be obtained from a local source.

www.reliablesprinkler.com

Model NS-ASAM

Model NS-Pak

Nitrogen Regulator

Nitrogen Automatic Pressure 

Maintenance Devices

Bulletin 254 May 2019

Summary of Contents for NS-ASAM

Page 1: ...easy wall mounting Nitrogen Regulator For bottled nitrogen use on single or multiple systems Low pressure switch for nitrogen source General Description Reliable Nitrogen Automatic Pressure Maintenance Devices are designed to connect nitrogen cylinders to dry pipe and preaction systems The NS ASAM is designed to connect a primary and secondary cylinder or bank of cylinders to sin gle or multiple s...

Page 2: ...l admit nitrogen or air from the primary source until the primary source depletes to a pres sure of approximately 80 psi 5 5 bar Nitrogen or air from the secondary source is admitted through the NS ASAM when the pressure of the nitrogen or air supplied by the primary source is less than approximately 80 psi 5 5 bar A pressure switch in the NS ASAM is factory set to activate at a pressure of 90 psi...

Page 3: ...stem pressure fully close the Bypass Valve 11 Slowly turn the adjustment screw of the System Pressure Regulator clockwise to increase pressure to the level required by the system Tighten the lock nut on the System Pressure Regulator see note 2 12 If desired supervise the contacts of the Pressure Switch in accordance with NFPA 72 to provide notification that the primary nitrogen or air source is de...

Page 4: ...00 psi 6 9 bar The high pressure regulator supplies a field adjustable System Pressure Regulator in the NS Pak controlling pressure to the system As the cylinder pressure depletes below 90 psi 6 2 bar the Inlet Pressure Switch activates to indicate low nitrogen pressure and notify the owner that the nitrogen supply requires servicing The field adjustable System Pressure Switch switch is factory pr...

Page 5: ...nnect the NS Pak outlet to the open port provided for pneumatic supply to the sprinkler system see note 1 9 Before applying pressure to the system turn the adjustment screw on the System Pressure Regulator within the NS Pak fully counterclockwise 10 Open the cylinder control valve and supply inlet valve in the NS Pak 11 Open the Bypass Valve and the NS Pak Outlet Valve to allow nitrogen to flow in...

Page 6: ...ce Device fully counterclockwise 8 Open the cylinder control valve 9 Open the bypass valve of the Pressure Maintenance De vice to allow nitrogen to flow into system piping 10 When the system pressure rises to within 2 psi of required system pressure fully close the bypass valve 11 Slowly turn the adjustment screw of the Pressure Mainte nance Device regulator clockwise to increase pressure to the l...

Page 7: ...tion Any system main tenance or testing that involves placing a system component out of service may eliminate the fire protection that is provided by the fire protection system The Reliable Model NS ASAM NS Pak and Nitrogen Regulator shall periodically be given a thorough inspection and test NFPA 25 Inspection Testing and Maintenance of Water Based Fire Protection Systems provides minimum maintena...