Ensure that the ThermoJet Oil Purifier Main Disconnect switch and the ON-OFF Selector Switch both are in
the OFF position.
Turn “ON” electrical power at the energy source breaker.
Turn the Main Disconnect handle to the ON position. Use the ON-OFF Selector switch to jog the electric
motor and check proper motor rotation. Verify the motor rotation against the directional arrow located on
drive end of the motor.
If incorrect, place the Circuit breaker in the OFF position and disconnect supply power at the source.
NOTICE:
Recycle all drained oils.
NOTICE:
Dispose of all contaminated cleaning materials in
accordance with all environmental laws, ordinances
and directives. Consult your company or plant
environmental protection department for disposal
policy. Understand the environmental effect of any
used cleaning agents used and plan your cleanup
accordingly.
Use environmentally friendly products and recycle
where ever possible
ON-OFF Selector Switch in
OFF position
Main Disconnect in OFF Position